Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Ratings | Usage | Features | Base Product Number | Length | Number of Conductors | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Cable Type | Shield Material | Voltage | Wire Gauge | Conductor Strand | Conductor Material | Jacket (Insulation) Material | Jacket (Insulation) Diameter | Shield Type | Jacket Color | Jacket (Insulation) Thickness | Conductor Insulation | Shield Coverage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
8723 0603280 | 4.0000 | ![]() |
1891 | 0.00000000 | Belden Inc. | Classics | Spool | Active | -20°C ~ 75°C | - | Audio, Control, Instrumentation | - | 8723 | 3281' (1000.0m) | 4 (2 Pair Twisted) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 22 AWG | 7/30 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.160" (4.06mm) | Foil | Chrome | 0.0200" (0.508mm) | Polypropylene (PP) | 100% | ||
![]() |
1036A 0061000 | 1.0000 | ![]() |
9049 | 0.00000000 | Belden Inc. | - | Spool | Active | -30°C ~ 105°C | UL Style 2464 | - | Drain Wire, Rip Cord | 1036A | 1000.0' (304.8m) | 3 (1 Triad Twisted) | - | Not Applicable | REACH Unaffected | BEL2169 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Aluminum | 18 AWG | 7/26 | Copper, Bare | Poly-Vinyl Chloride (PVC) | 0.266" (6.76mm) | Foil | Blue | 0.0370" (0.940mm) | Poly-Vinyl Chloride (PVC) | 100% | |||
![]() |
1331A 0031000 | - | ![]() |
1233 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 105°C | - | - | Drain Wire, Oil Resistant, Rip Cord | 1331A | 1000.0' (304.8m) | 32 (16 Pair Twisted) | - | Not Applicable | REACH Unaffected | BEL2179 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.920" (23.37mm) | Foil | Orange | - | Polyolefin (PO) | 100% | ||
![]() |
7933A 1NH1000 | 1.0000 | ![]() |
7410 | 0.00000000 | Belden Inc. | DataTuff® | Spool | Active | -40°C ~ 80°C | UL Style CMR | Industrial, Network | Drain Wire, Oil Resistant, UV Resistant | 7933A | 1000.0' (304.8m) | 4 (2 Pair Twisted) | download | Not Applicable | REACH Unaffected | BEL2241 | EAR99 | 8544.49.3080 | 1 | Multi-Pair, Cat5e | Aluminum; Copper, Tinned | 300 V | 24 AWG | Solid | Copper, Bare | Thermoplastic Elastomer (TPE) | 0.265" (6.73mm) | Foil, Braid | Teal | - | Polyolefin (PO) | 100%, 85% | ||
![]() |
9332 060500 | 6.0000 | ![]() |
2040 | 0.00000000 | Belden Inc. | - | Spool | Active | -30°C ~ 105°C | UL Style 2464 | Audio, Control, Instrumentation | Direct Burial, Drain Wire, Ripcord, UV Resistant | 9332 | 500.0' (152.4m) | 18 (9 Pair) | download | Not Applicable | REACH Unaffected | BEL2285 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 22 AWG | 7/30 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.530" (13.46mm) | Foil | Chrome | 0.0530" (1.346mm) | Poly-Vinyl Chloride (PVC) | 100% | |||
![]() |
9363 060U1000 | 1.0000 | ![]() |
1 | 0.00000000 | Belden Inc. | - | Spool | Active | -30°C ~ 105°C | UL Style 2464 | Instrumentation | Drain Wire, Rip Cord | 9363 | 1000.0' (304.8m) | 3 (1 Triad) | download | Not Applicable | REACH Unaffected | BEL2297 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Aluminum | 22 AWG | 7/30 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.210" (5.33mm) | Foil | Chrome | 0.0370" (0.940mm) | Poly-Vinyl Chloride (PVC) | 100% | |||
![]() |
9514 0601000 | 3.0000 | ![]() |
8673 | 0.00000000 | Belden Inc. | - | Spool | Active | -30°C ~ 105°C | UL Style 2464 | Instrumentation | Drain Wire, Flame Retardant, Rip Cord | 9514 | 1000.0' (304.8m) | 8 (4 Pair) | download | Not Applicable | REACH Unaffected | BEL2348 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 22 AWG | 7/30 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.356" (9.04mm) | Foil | Chrome | 0.0420" (1.067mm) | Poly-Vinyl Chloride (PVC) | 100% | ||
![]() |
9554 060500 | 4.0000 | ![]() |
8998 | 0.00000000 | Belden Inc. | - | Spool | Active | -30°C ~ 105°C | UL Style 2464 | Instrumentation | Drain Wire, Rip Cord | 9554 | 500.0' (152.4m) | 8 (4 Pair) | download | Not Applicable | REACH Unaffected | BEL2364 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 18 AWG | 19/30 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.466" (11.84mm) | Foil | Chrome | 0.0530" (1.346mm) | Poly-Vinyl Chloride (PVC) | 100% | |||
![]() |
73007WS 008100 | 360.1700 | ![]() |
4744 | 0.00000000 | Belden Inc. | MachFlex™ | Spool | Active | -5°C ~ 90°C | UL Style 2587 | Industrial, Signal, Control | Oil Resistant | 73007WS | 100.0' (30.5m) | 7 | - | Not Applicable | REACH Unaffected | BEL2384-100 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Copper, Tinned | 600 V | 20 AWG | 10/30 | Copper, Bare | Poly-Vinyl Chloride (PVC) | 0.409" (10.39mm) | Braid | Gray | 0.0350" (0.889mm) | Poly-Vinyl Chloride (PVC) | 85% | ||
![]() |
73012W 008100 | 411.4000 | ![]() |
4739 | 0.00000000 | Belden Inc. | MachFlex™ | Spool | Active | - | UL Style 2587 | Industrial, Signal, Control | Oil Resistant | 73012W | 100.0' (30.5m) | 12 | - | Not Applicable | REACH Unaffected | BEL2386-100 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | - | 600 V | 20 AWG | 10/30 | Copper, Bare | Poly-Vinyl Chloride (PVC) | 0.433" (11.00mm) | - | Gray | 0.0450" (1.143mm) | Poly-Vinyl Chloride (PVC) | - | ||
![]() |
76514TS 008100 | 984.2400 | ![]() |
2664 | 0.00000000 | Belden Inc. | MachFlex™ | Spool | Active | - | UL Style 20006 | - | Drain Wire, Oil Resistant | 76514TS | 100.0' (30.5m) | 28 (14 Pair) | - | Not Applicable | REACH Unaffected | BEL2475-100 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum; Copper, Tinned | 300 V | 26 AWG | 7/34 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.426" (10.82mm) | Foil, Braid | Gray | 0.0530" (1.346mm) | Poly-Vinyl Chloride (PVC) | 100%, 85% | ||
![]() |
7105W 003250 | 9.6143 | ![]() |
3710 | 0.00000000 | Belden Inc. | MachFlex™ | Spool | Active | -50°C ~ 90°C | UL Style 20327 | Industrial, Signal, Control | Oil Resistant, UV Resistant | 7105W | 250.0' (76.2m) | 9 | download | Not Applicable | REACH Unaffected | BEL2521-250 | EAR99 | 8544.49.3080 | 250 | Multi-Conductor | - | 20 AWG | 74/38 | Copper, Bare | Thermoplastic Elastomer (TPE) | 0.376" (9.55mm) | - | Orange | 0.0420" (1.067mm) | Poly-Vinyl Chloride (PVC) | - | |||
![]() |
76012WS 008500 | - | ![]() |
5052 | 0.00000000 | Belden Inc. | MachFlex™ | Spool | Active | - | - | - | Oil Resistant | 76012WS | 500.0' (152.4m) | 12 | - | Not Applicable | REACH Unaffected | BEL2664-500 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Aluminum; Copper, Tinned | 300 V | 28 AWG | 7/36 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.283" (7.19mm) | Foil, Spiral | Chrome | 0.0400" (1.016mm) | Poly-Vinyl Chloride (PVC) | 100%, 90% | ||
![]() |
76303WS 008500 | 700.3100 | ![]() |
9565 | 0.00000000 | Belden Inc. | MachFlex™ | Spool | Active | - | - | - | Oil Resistant | 76303WS | 500.0' (152.4m) | 3 | download | Not Applicable | REACH Unaffected | BEL2675-500 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Aluminum; Copper, Tinned | 300 V | 22 AWG | 19/34 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.217" (5.51mm) | Foil, Spiral | Chrome | 0.0400" (1.016mm) | Poly-Vinyl Chloride (PVC) | 100%, 90% | ||
![]() |
1119A 0101000 | 2.0000 | ![]() |
7721 | 0.00000000 | Belden Inc. | - | Spool | Active | - | - | - | Drain Wire, Rip Cord | 1119A | 1000.0' (304.8m) | 3 (1 Triad Twisted) | - | Not Applicable | REACH Unaffected | BEL2718-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Aluminum | 16 AWG | 7/24 | Copper, Bare | Poly-Vinyl Chloride (PVC) | 0.315" (8.00mm) | Foil | Black | 0.0470" (1.194mm) | Poly-Vinyl Chloride (PVC), Polyamide (PA), Nylon | 100% | |||
![]() |
11700A 0081000 | 1.0000 | ![]() |
4626 | 0.00000000 | Belden Inc. | DataTuff® | Spool | Active | -40°C ~ 75°C | UL Style CMR | Industrial, Network | Oil Resistant, Rip Cord, UV Resistant | 11700A | 1000.0' (304.8m) | 8 (4 Pair Twisted) | download | Not Applicable | REACH Unaffected | BEL2721-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair, Cat5e | - | 300 V | 24 AWG | Solid | Copper, Bare | Poly-Vinyl Chloride (PVC) | 0.285" (7.24mm) | - | Gray | 0.0350" (0.889mm) | Polyolefin (PO) | - | ||
![]() |
121700A 0101000 | 6.9068 | ![]() |
9917 | 0.00000000 | Belden Inc. | DataTuff® | Spool | Active | -40°C ~ 75°C | - | Industrial, Network | Oil Resistant, Rip Cord, UV Resistant | 121700A | 1000.0' (304.8m) | 8 (4 Pair Twisted) | download | Not Applicable | REACH Unaffected | BEL2725-1000 | EAR99 | 8544.49.3080 | 1,000 | Multi-Pair, Cat5e | - | 300 V | 24 AWG | Solid | Copper, Bare | Poly-Vinyl Chloride (PVC) | 0.553" (14.05mm) | - | Black | 0.0450" (1.143mm) | Polyolefin (PO) | - | ||
![]() |
1361A 0031000 | 5.0000 | ![]() |
3767 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 105°C | - | - | Drain Wire, Oil Resistant | 1361A | 1000.0' (304.8m) | 4 (2 Pair) | - | Not Applicable | REACH Unaffected | BEL2735-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.577" (14.66mm) | Foil | Orange | 0.0550" (1.397mm) | Polyolefin (PO) | 100% | ||
![]() |
1364A 0031000 | 18.7042 | ![]() |
1385 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 105°C | - | - | Drain Wire, Oil Resistant | 1364A | 1000.0' (304.8m) | 24 (12 Pair) | download | Not Applicable | REACH Unaffected | BEL2738-1000 | EAR99 | 8544.49.3080 | 1,000 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.105" (28.07mm) | Foil | Orange | 0.0750" (1.905mm) | Polyolefin (PO) | 100% | ||
![]() |
2106A 0061000 | 30.7473 | ![]() |
1251 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire, Rip Cord | 2106A | 1000.0' (304.8m) | 40 (20 Pair Twisted) | download | Not Applicable | REACH Unaffected | BEL2754-1000 | EAR99 | 8544.49.3080 | 1,000 | Multi-Pair | Aluminum | 300 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.249" (31.73mm) | Foil | Blue | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | ||
![]() |
2123A 0061000 | 25.9214 | ![]() |
1219 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | UL Style TC-ER | - | Drain Wire, Oil Resistant, Rip Cord, UV Resistant | 2123A | 1000.0' (304.8m) | 32 (16 Pair Twisted) | download | Not Applicable | REACH Unaffected | BEL2786-1000 | EAR99 | 8544.49.3080 | 1,000 | Multi-Pair | Aluminum | 600 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.126" (28.60mm) | Foil | Blue | 0.0850" (2.159mm) | Polyolefin (PO) | 100% |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse