Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Mounting Type Features Base Product Number Approval Agency Termination Ingress Protection DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Filter Type Connector Type Material Flammability Rating Number of Positions Panel Cutout Dimensions Connector Style Panel Thickness Current Rating - Appliance Inlet Voltage Rating - Appliance Inlet Current Rating - Filter Switch Features Current Rating - Circuit Breaker Accomodates a Fuse Fuse Holder, Drawer
PE972203 Curtis Industries PE972203 -
RFQ
ECAD 9787 0.00000000 Curtis Industries PE9 Bulk Obsolete Panel Mount, Flange Voltage Selector CE, CSA, TUV, UL Quick Connect - 0.110" (2.8mm) - download RoHS Compliant 1 (Unlimited) EAR99 8536.30.8000 10 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.50mm x 70.20mm IEC 320-C14 - 3A 250VAC - Switch On-Off - Yes (Fuse Not Included) Fuse Holder
3-6609947-4 TE Connectivity Corcom Filters 3-6609947-4 25.5738
RFQ
ECAD 8356 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Voltage Selector 6609947 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSJ0XDH3A EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 3A 120VAC 3A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
710W-00/06 Qualtek 710W-00/06 -
RFQ
ECAD 3766 0.00000000 Qualtek 710W Bulk Active Panel Mount, Flange - 710W-00 CSA, TUV, UL Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 100 Unfiltered - Commercial Receptacle, Female Sockets - 3 Rectangular - 32.50mm x 25.00mm IEC 320-2-2/F - 10A 250VAC - - - No -
6162.0157 SCHURTER Inc. 6162.0157 2.0900
RFQ
ECAD 126 0.00000000 SCHURTER Inc. 6061 Bulk Active Panel Mount, Flange - cCSAus, ENEC, UR Solder IP20 download ROHS3 Compliant Not Applicable REACH Unaffected 486-4850 EAR99 8536.69.4030 50 Unfiltered - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 27.30mm x 19.50mm IEC 320-C14 - 10A 250VAC - - - No -
7-6609948-5 TE Connectivity Corcom Filters 7-6609948-5 28.5844
RFQ
ECAD 2535 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Voltage Selector 6609948 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSLSXDHX0 EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
1-1609112-8 TE Connectivity Corcom Filters 1-1609112-8 10.0400
RFQ
ECAD 816 0.00000000 TE Connectivity Corcom Filters CU, Corcom Bulk Last Time Buy Panel Mount, Snap-In - 1609112 CSA, UL, VDE Quick Connect - 0.189" (4.8mm) - download ROHS3 Compliant 1 (Unlimited) REACH Affected EAR99 8537.10.9170 42 Unfiltered - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 26.70mm x 31.60mm IEC 320-C14 0.059" (1.50mm) 15A 120/250VAC - Switch On-Off - No -
7-6609941-7 TE Connectivity Corcom Filters 7-6609941-7 25.5742
RFQ
ECAD 1623 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Shielded, Voltage Selector 6609941 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 54.10mm IEC 320-C14 - 3A 120VAC 3A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
7-6609942-7 TE Connectivity Corcom Filters 7-6609942-7 29.2225
RFQ
ECAD 6107 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Voltage Selector 6609942 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSCSSDS6A EAR99 8536.69.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 6A 120VAC 6A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
6-6609941-4 TE Connectivity Corcom Filters 6-6609941-4 25.5900
RFQ
ECAD 1515 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Voltage Selector 6609941 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 Rectangular - 26.92mm x 54.10mm IEC 320-C14 - 10A 120VAC 10A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
6-6609940-6 TE Connectivity Corcom Filters 6-6609940-6 27.3575
RFQ
ECAD 5003 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Conversion Clip, Voltage Selector 6609940 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 26.92mm x 54.10mm IEC 320-C14 - 6A 120VAC 6A Switch On-Off - Yes (Fuse Not Included) Fuse Holder
FN394E-6-05-11 Schaffner EMC Inc. FN394E-6-05-11 50.8100
RFQ
ECAD 19 0.00000000 Schaffner EMC Inc. FN 390 Tray Active Panel Mount, Flange Earth Line Choke, Front or Rear Side Mount, Voltage Selector FN394 CSA, ENEC, UL Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.30.8000 20 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module UL94 V-2 3 Rectangular - 29.00mm x 60.00mm IEC 320-C14 - - - 6A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
03IB2S Delta Electronics 03IB2S 23.1100
RFQ
ECAD 27 0.00000000 Delta Electronics IB Bulk Active Panel Mount, Flange - CSA, UL, VDE Quick Connect - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1144-1195 EAR99 8536.30.8000 36 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 29.00mm x 60.00mm IEC 320-C14 - 3A 115/250VAC - Switch On-Off - Yes (Fuse Not Included) Fuse Holder
FN9244S1R-3-06 Schaffner EMC Inc. FN9244S1R-3-06 9.0800
RFQ
ECAD 2383 0.00000000 Schaffner EMC Inc. FN 9244 Tray Active Panel Mount, Snap-In Bleed Resistor FN9244 CQC, CSA, ENEC, UL Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.30.8000 120 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-2 3 Rectangular - 28.50mm x 21.90mm IEC 320-C14 0.028" ~ 0.059" (0.70mm ~ 1.50mm) - - 3A - - No -
6162.0066 SCHURTER Inc. 6162.0066 -
RFQ
ECAD 7186 0.00000000 SCHURTER Inc. 6062 Bulk Obsolete Panel Mount, Flange - cCSAus, ENEC, UL Quick Connect - 0.250" (6.3mm) IP20 download ROHS3 Compliant Vendor Undefined REACH Unaffected EAR99 8536.69.4030 50 Unfiltered - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 27.20mm x 19.50mm IEC 320-C14 - 10A 250VAC - - - No -
PS20/A0620/63 Bulgin PS20/A0620/63 -
RFQ
ECAD 7729 0.00000000 Bulgin PS20 Bulk Obsolete Panel Mount, Flange - CSA, ENEC, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.69.4030 100 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 29.25mm x 33.25mm IEC 320-C14 - 6A 250VAC 6A - - Yes (Fuse Not Included) Fuse Holder
5145.1184.631 SCHURTER Inc. 5145.1184.631 60.6600
RFQ
ECAD 8326 0.00000000 SCHURTER Inc. 5145 Bulk Active Panel Mount, Flange - 5145.1184 cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 5145.ABDWF065C0.631 EAR99 8536.30.8000 20 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module UL94 V-0 3 Rectangular - 29.00mm x 72.00mm IEC 320-C14 - 10A 250VAC 8A Circuit Breaker, Switch On-Off 6.5A No -
6609987-8 TE Connectivity Corcom Filters 6609987-8 5.4300
RFQ
ECAD 4 0.00000000 TE Connectivity Corcom Filters SRB, Corcom Bulk Active Panel Mount, Flange Front or Rear Side Mount, Shielded 6609987 CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Affected EAR99 8536.69.4030 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C14 - 15A 120/250VAC 15A - - No -
7-6609955-2 TE Connectivity Corcom Filters 7-6609955-2 20.6163
RFQ
ECAD 1882 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Interconnection Block, Voltage Selector 6609955 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
2-6609949-7 TE Connectivity Corcom Filters 2-6609949-7 26.7194
RFQ
ECAD 1915 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Voltage Selector 6609949 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSLS0DH30 EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 3A 120VAC 3A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
7-6609930-7 TE Connectivity Corcom Filters 7-6609930-7 27.4719
RFQ
ECAD 6095 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Shielded 6609930 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
2-1609113-6 TE Connectivity Corcom Filters 2-1609113-6 27.8000
RFQ
ECAD 716 0.00000000 TE Connectivity Corcom Filters CU, Corcom Bulk Active Panel Mount, Flange - 1609113 CSA, UL, VDE Quick Connect - 0.189" (4.8mm) - download ROHS3 Compliant 1 (Unlimited) REACH Affected EAR99 8537.10.9170 42 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.10mm x 31.90mm IEC 320-C14 - 10A 250VAC 10A Switch On-Off - No -
6162.0058 SCHURTER Inc. 6162.0058 1.9900
RFQ
ECAD 29 0.00000000 SCHURTER Inc. 6061 Bulk Active Panel Mount, Flange - cCSAus, ENEC, UL Quick Connect - 0.250" (6.3mm) IP20 - ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 50 Unfiltered - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 27.30mm x 19.50mm IEC 320-C14 - 10A 250VAC - - - No -
5110.0833.1 SCHURTER Inc. 5110.0833.1 17.9200
RFQ
ECAD 8 0.00000000 SCHURTER Inc. 5110 Bulk Active Panel Mount, Flange - 5110.0833 CCC, cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 10 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 29.00mm x 21.00mm IEC 320-C14 - 8A 250VAC 8A - - No -
864-10/011 Qualtek 864-10/011 30.7900
RFQ
ECAD 124 0.00000000 Qualtek 864 Tray Active Panel Mount, Flange Voltage Selector 864-10 CSA, UL, VDE Quick Connect - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 10 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.96mm x 60.20mm IEC 320-C14 - 4/6A 250VAC - Switch On-Off - Yes (Fuse Not Included) Fuse Holder
3-6609940-0 TE Connectivity Corcom Filters 3-6609940-0 27.7992
RFQ
ECAD 5323 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Voltage Selector 6609940 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 Rectangular - 26.92mm x 54.10mm IEC 320-C14 - 6A 120VAC 6A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
CG30.6101.151 SCHURTER Inc. CG30.6101.151 74.0300
RFQ
ECAD 10 0.00000000 SCHURTER Inc. CG Bulk Active Panel Mount, Flange Voltage Selector CG30.6101 cULus, ENEC Quick Connect - 0.189" (4.8mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 5 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module UL94 V-0 3 Rectangular - 28.50mm x 81.00mm IEC 320-C14 - 10A 250VAC 4A Switch On-Off - Yes (Fuse Not Included) Drawer Sold Separate
FASAS01PFR XP Power FASAS01PFR 6.6000
RFQ
ECAD 59 0.00000000 XP Power FASA Tray Active Panel Mount, Snap-In Bleed Resistor, Shielded FASAS01 CE, cURus, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable 1470-4745 EAR99 8536.69.8000 35 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-2 3 Rectangular - 21.50mm x 28.60mm IEC 320-C14 0.031" ~ 0.063" (0.79mm ~ 1.60mm) 1A 115/230VAC 1A - - No -
FN9299B-10-06 Schaffner EMC Inc. FN9299B-10-06 35.3450
RFQ
ECAD 9453 0.00000000 Schaffner EMC Inc. FN 9290 Bulk Active Panel Mount, Snap-In - CE, CQC, CSA, ENEC, UL Quick Connect - 0.250" (6.3mm) IP40 - 817-FN9299B-10-06 40 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module UL94 V-2 3 Rectangular - 28.80mm x 47.80mm IEC 320-C14 0.039" ~ 0.098" (1.00mm ~ 2.50mm) - - 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
5707.0605.312 SCHURTER Inc. 5707.0605.312 35.3100
RFQ
ECAD 10 0.00000000 SCHURTER Inc. 5707 Bulk Active Panel Mount, Flange Shielded 5707.0605 cULus, ENEC Quick Connect - 0.250" (6.3mm) IP65 - Dust Tight, Water Resistant download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 10 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades UL94 V-0 3 Rectangular - 36.00mm x 32.20mm IEC 320-C14 - 6A 250VAC 6A - - Yes (Fuse Not Included) Fuse Holder
6163.0004 SCHURTER Inc. 6163.0004 3.1300
RFQ
ECAD 12 0.00000000 SCHURTER Inc. 1621 Bulk Active Panel Mount, Flange - cCSAus, ENEC, UL Quick Connect - 0.250" (6.3mm) IP20 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.8000 50 Unfiltered - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 32.40mm x 24.40mm IEC 320-C20 - 16A 250VAC - - - No -