Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Mounting Type | Type | Features | Base Product Number | Includes | Color | Termination | Ingress Protection | Note | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | Other Names | ECCN | HTSUS | Standard Package | Connector Type | Current Rating (Amps) | Orientation | Shielding | Contact Material | Material Flammability Rating | Contact Type | Number of Positions | Fastening Type | Contact Shape | Contact Finish - Mating | Contact Finish Thickness - Mating | Voltage Rating | Mounting Feature | Shell Size - Insert | Shell Size, MIL | Primary Material | Shell Material | Shell Finish | Cable Opening | Backshell Material, Plating | Insert Material | Housing Color | Contact Size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
BACC63BP12D12S7H | 1.0000 | ![]() |
8028 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Female Sockets | Coupling Nut, Self Locking | BACC63BP | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | Not Applicable | CBACC63BP12D12S7H | EAR99 | 8538.90.8180 | 1 | Plug Housing | 7 | Shielded | - | Crimp | 12 (Power) | Threaded | Circular | - | 12-12 | - | Stainless Steel | - | Epoxy, Glass Filled | Silver | 20 Power | ||||||||||||
![]() |
CN0967C12S12S7-200 | 1.0000 | ![]() |
5953 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0967 | Bulk | Active | -55°C ~ 200°C | - | Panel Mount | - | CN096 | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CCN0967C12S12S7-200 | EAR99 | 8536.69.4020 | 1 | Receptacle, Female Sockets | - | 7 | Shielded | - | - | 12 (Power) | Threaded | Gold | 50.0µin (1.27µm) | - | Flange | 12-12 | - | Metal | Stainless Steel | - | 0.547" (13.89mm) | - | - | ||||||||
![]() |
C48-10R10Y2S-406 | 1.0000 | ![]() |
2213 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, C48 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Female Sockets | - | C48-10R1 | - | IP66 - Dust Tight, Water Resistant | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CC48-10R10Y2S-406 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | N (Normal) | Unshielded | - | Crimp | 2 (Power) | Bayonet Lock | Circular | Flange | 10-2 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 20 Power | ||||||||||||
![]() |
BACC63BV22F12P7 | 1.0000 | ![]() |
6183 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | - | Panel Mount | - | BACC63BV | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CBACC63BV22F12P7 | EAR99 | 8536.69.4020 | 1 | Receptacle, Male Pins | - | 7 | Shielded | - | - | 12 (Power) | Threaded | Gold | 50.0µin (1.27µm) | - | Flange | 22-12 | - | Metal | Aluminum | Cadmium over Nickel | 1.106" (28.09mm) | - | - | ||||||||
![]() |
MS24266R14B7SY | 1.0000 | ![]() |
5615 | 0.00000000 | Cinch Connectivity Solutions | Military, MIL-DTL-26500 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Coupling Nut | MS24266R14B | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CMS24266R14B7SY | EAR99 | 8536.69.4020 | 1 | Plug, Female Sockets | - | Y | Unshielded | - | - | 7 (Power) | Bayonet Lock | Gold | 50.0µin (1.27µm) | - | - | 14-7 | D | Metal | Aluminum | Anodized | 0.664" (16.87mm) | - | Epoxy, Glass Filled | ||||||||
![]() |
CN0967C24A61P7Y040 | 1.0000 | ![]() |
6309 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0967 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | CN096 | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN0967C24A61P7Y040 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 7 | Shielded | - | Crimp | 61 (Power) | Threaded | Circular | Flange | 24-61 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 20 Power | ||||||||||||
![]() |
BACC63CB14-15P9 | 1.0000 | ![]() |
8349 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Coupling Nut | BACC63CB | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CBACC63CB14-15P9 | EAR99 | 8536.69.4020 | 1 | Plug, Male Pins | - | 9 | Shielded | - | - | 15 (Power) | Bayonet Lock | Gold | 50.0µin (1.27µm) | - | - | 14-15 | - | Metal | Aluminum | Cadmium over Nickel | 0.613" (15.57mm) | - | - | ||||||||
![]() |
BACC63CB14-3PNH | 1.0000 | ![]() |
3018 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Male Pins | Coupling Nut | BACC63CB | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CBACC63CB14-3PNH | EAR99 | 8538.90.8180 | 1 | Plug Housing | N (Normal) | Shielded | - | Crimp | 3 (1 + 2 Power) | Bayonet Lock | Circular | - | 14-3 | - | Aluminum | Bright Cadmium | Epoxy, Glass Filled | Silver | 2 (1), 16 Power (2) | ||||||||||||
![]() |
CN0967C18A14P6-000 | 1.0000 | ![]() |
4427 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0967 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | CN096 | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN0967C18A14P6-000 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 6 | Shielded | - | Crimp | 14 (Power) | Threaded | Circular | Flange | 18-14 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 16 Power | ||||||||||||
![]() |
CN0966A14A07P6-040 | 1.0000 | ![]() |
3115 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0966 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Male Pins | Coupling Nut, Self Locking | CN096 | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN0966A14A07P6-040 | EAR99 | 8538.90.8180 | 1 | Plug Housing | 6 | Unshielded | - | Crimp | 7 (Power) | Threaded | Circular | - | 14-7 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 16 Power | ||||||||||||
![]() |
BACC63BV14F15S6H | 1.0000 | ![]() |
9756 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Female Sockets | - | BACC63BV | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CBACC63BV14F15S6H | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 6 | Shielded | - | Crimp | 15 (Power) | Threaded | Circular | Flange | 14-15 | - | Aluminum | Cadmium | Epoxy, Glass Filled | Silver | 20 Power | ||||||||||||
![]() |
CN0967C18G14P6-240 | 130.7800 | ![]() |
76 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0967 | Bulk | Active | -55°C ~ 200°C | - | Panel Mount | - | CN096 | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CCN0967C18G14P6-240 | EAR99 | 8536.69.4020 | 1 | Receptacle, Male Pins | - | 6 | Shielded | - | - | 14 (Power) | Threaded | - | - | - | Flange | 18-14 | - | Metal | Aluminum | Cadmium over Nickel | 0.865" (21.97mm) | - | - | ||||||||
![]() |
BACC45FT22A19P8 | 1.0000 | ![]() |
3662 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC45 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Cable Clamp, Coupling Nut | BACC45FT | - | Crimp | Environment Sealed | download | RoHS non-compliant | Not Applicable | CBACC45FT22A19P8 | EAR99 | 8536.69.4020 | 1 | Plug, Male Pins | - | 8 | Unshielded | - | - | 19 (Power) | Bayonet Lock | Gold | 50.0µin (1.27µm) | - | - | 22-19 | - | Metal | Aluminum | Anodized | 1.152" (29.26mm) | - | Epoxy, Glass Filled | ||||||||
![]() |
CN0967C22G55P10Y040 | 1.0000 | ![]() |
6875 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0967 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | CN096 | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN0967C22G55P10Y040 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 10 | Shielded | - | Crimp | 55 (Power) | Threaded | Circular | Flange | 22-55 | - | Aluminum | Cadmium over Nickel | Epoxy, Glass Filled | Silver | 20 Power | ||||||||||||
![]() |
BACC45FN24-43P7H | 107.5000 | ![]() |
33 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC45 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | BACC45FN | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CBACC45FN24-43P7H | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 7 | Unshielded | - | Crimp | 43 (Power) | Bayonet Lock | Circular | Flange | 24-43 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 16 Power (20), 20 Power (23) | ||||||||||||
![]() |
BACC45FS22-12S | 1.0000 | ![]() |
8789 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC45 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Coupling Nut | BACC45FS | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CBACC45FS22-12S | EAR99 | 8536.69.4020 | 1 | Plug, Female Sockets | - | N (Normal) | Unshielded | - | - | 12 (Power) | Threaded | Gold | 50.0µin (1.27µm) | - | - | 22-12 | - | Metal | Aluminum | Anodized | 1.152" (29.26mm) | - | Epoxy, Glass Filled | ||||||||
![]() |
CN0967C16G24S6Y040 | 1.0000 | ![]() |
8891 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0967 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Female Sockets | - | CN096 | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN0967C16G24S6Y040 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 6 | Shielded | - | Crimp | 24 (Power) | Threaded | Circular | Flange | 16-24 | - | Aluminum | Cadmium over Nickel | Epoxy, Glass Filled | Silver | 20 Power | ||||||||||||
![]() |
CN0967C24S30S7-040 | 1.0000 | ![]() |
8108 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0967 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Female Sockets | - | CN096 | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN0967C24S30S7-040 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 7 | Shielded | - | Crimp | 30 (Power) | Threaded | Circular | Flange | 24-30 | - | Stainless Steel | - | Epoxy, Glass Filled | Silver | 16 Power | ||||||||||||
![]() |
CN1021A18G08P6-000 | 1.0000 | ![]() |
2250 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN1021 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | CN102 | - | IP66 - Dust Tight, Water Resistant | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN1021A18G08P6-000 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 6 | Shielded | - | Crimp | 8 (Power) | Bayonet Lock | Circular | Flange | 18-8 | - | Aluminum | Cadmium over Nickel | Epoxy, Glass Filled | Silver | 12 Power | ||||||||||||
![]() |
CN0967C24S61S10Y040 | 1.0000 | ![]() |
9683 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0967 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Female Sockets | - | CN096 | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN0967C24S61S10Y040 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 10 | Shielded | - | Crimp | 61 (Power) | Threaded | Circular | Flange | 24-61 | - | Stainless Steel | - | Epoxy, Glass Filled | Silver | 20 Power | ||||||||||||
![]() |
C0909A10-05P7Y402 | 1.0000 | ![]() |
6742 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, C0909A | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Coupling Nut | C0909A10 | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CC0909A10-05P7Y402 | EAR99 | 8536.69.4020 | 1 | Plug, Male Pins | - | 7 | - | - | - | 5 (Power) | Bayonet Lock | Gold | 50.0µin (1.27µm) | - | - | 10-5 | - | Metal | Aluminum | Anodized | 0.420" (10.67mm) | - | - | ||||||||
![]() |
BACC63CB14-3P6H | 1.0000 | ![]() |
1936 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Male Pins | Coupling Nut | BACC63CB | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CBACC63CB14-3P6H | EAR99 | 8538.90.8180 | 1 | Plug Housing | 6 | Shielded | - | Crimp | 3 (1 + 2 Power) | Bayonet Lock | Circular | - | 14-3 | - | Aluminum | Bright Cadmium | Epoxy, Glass Filled | Silver | 2 (1), 16 Power (2) | ||||||||||||
![]() |
CN0967C28S42P10-040 | 1.0000 | ![]() |
9221 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0967 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | CN096 | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN0967C28S42P10-040 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 10 | Shielded | - | Crimp | 42 (Power) | Threaded | Circular | Flange | 28-42 | - | Stainless Steel | - | Epoxy, Glass Filled | Silver | 16 Power | ||||||||||||
![]() |
MD801-007-16NF8-13PF | 126.1540 | ![]() |
7577 | 0.00000000 | Cinch Connectivity Solutions | MD801 | Bag | Active | -65°C ~ 175°C | Aerospace, Military | Free Hanging (In-Line) | Coupling Nut | Olive Drab | Crimp | IP67 - Dust Tight, Waterproof | download | RoHS non-compliant | Not Applicable | 116-MD801-007-16NF8-13PF | EAR99 | 8536.69.4020 | 1 | Plug, Male Pins | 5A | F | Shielded | - | - | 13 | Threaded | - | - | - | - | 8-13 | - | Aluminum | Olive Drab Chromate over Cadmium | - | - | - | ||||||||||
![]() |
MS24264R8B3P8-LC | 1.0000 | ![]() |
7545 | 0.00000000 | Cinch Connectivity Solutions | Military, MIL-DTL-26500 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | MS24264R8B | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CMS24264R8B3P8-LC | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 8 | Unshielded | - | Crimp | 3 (Power) | Bayonet Lock | Circular | Flange | 8-3 | A | Aluminum | Anodized | Epoxy, Glass Filled | Black | 20 Power | ||||||||||||
![]() |
BACC45FT10-20P10H | 79.7400 | ![]() |
4 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC45 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Male Pins | Coupling Nut | BACC45FT | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CBACC45FT10-20P10H | EAR99 | 8538.90.8180 | 1 | Plug Housing | 10 | Unshielded | - | Crimp | 2 (Power) | Bayonet Lock | Circular | - | 10-20 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 16 Power | ||||||||||||
![]() |
BACC63BV10B2S7 | 1.0000 | ![]() |
6246 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | - | Panel Mount | - | BACC63BV | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CBACC63BV10B2S7 | EAR99 | 8536.69.4020 | 1 | Receptacle, Female Sockets | - | 7 | Shielded | - | - | 2 (Power) | Threaded | Gold | 50.0µin (1.27µm) | - | Flange | 10-2 | - | Metal | Stainless Steel | - | 0.371" (9.42mm) | - | - | ||||||||
![]() |
MD801-009-07NF6-4PF | 79.7150 | ![]() |
8780 | 0.00000000 | Cinch Connectivity Solutions | MD801 | Bag | Active | -65°C ~ 175°C | Aerospace, Military | Panel Mount | - | Olive Drab | Crimp | IP67 - Dust Tight, Waterproof | download | RoHS non-compliant | 1 (Unlimited) | 116-MD801-009-07NF6-4PF | EAR99 | 8536.69.4020 | 1 | Receptacle, Male Pins | 5A | F | Shielded | - | - | 4 | Threaded | - | - | - | Bulkhead - Front Side Nut | 6-4 | - | Metal | Aluminum | Olive Drab Chromate over Cadmium | 0.290" (7.37mm) | - | - | |||||||||
![]() |
BACC63CC20-25S6 | 1.0000 | ![]() |
2915 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | - | Panel Mount | - | BACC63CC | - | Crimp | Environment Sealed | download | RoHS non-compliant | Not Applicable | CBACC63CC20-25S6 | EAR99 | 8536.69.4020 | 1 | Receptacle, Female Sockets | - | 6 | Shielded | - | - | 25 (Power) | Bayonet Lock | Gold | 50.0µin (1.27µm) | - | Flange | 20-25 | - | Metal | Aluminum | Cadmium over Nickel | 0.986" (25.04mm) | - | - | ||||||||
![]() |
MS24266R20T25P7-LC | 1.0000 | ![]() |
4819 | 0.00000000 | Cinch Connectivity Solutions | Military, MIL-DTL-26500 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Male Pins | Coupling Nut | MS24266R20T | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CMS24266R20T25P7-LC | EAR99 | 8538.90.8180 | 1 | Plug Housing | 7 | Unshielded | - | Crimp | 25 (Power) | Threaded | Circular | - | 20-25 | G | Aluminum | Anodized | Epoxy, Glass Filled | Black | 12 Power (6), 20 Power (19) |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse