Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Voltage - Rated | Lifetime @ Temp. | Operating Temperature | Size / Dimension | Material | Features | Base Product Number | For Use With/Related Products | Voltage Range | Approval Agency | Termination | Ingress Protection | Length | Width | Weight | Cord Type | Style | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Current Rating (Amps) | 1st Connector | 2nd Connector | Approval Agency Marking | Air Flow | Wire Gauge | Static Pressure | Bearing Type | Fan Type | Noise | RPM | Material - Frame | Material - Blade | Fan Accessory Type | Fits Fan Size | Fits Terminal Size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
ME70202V1-000U-A99 | 5.8800 | ![]() |
3 | 0.00000000 | Sunon Fans | MagLev® ME | Bulk | Last Time Buy | 24VDC | 70000 Hrs @ 40°C | 14 ~ 158°F (-10 ~ 70°C) | Square - 70mm L x 70mm H | Auto Restart | ME70202V1 | 8 ~ 27.6VDC | CE, CUR, TUV, UL | 2 Wire Leads | - | 20.00mm | 0.133 lb (60.33 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 259-1993 | EAR99 | 8414.59.6590 | 1 | 1.59 W | 0.066A | 29.0 CFM (0.812m³/min) | 0.140 in H2O (34.9 Pa) | Vapo-Bearing™ | Tubeaxial | 33.0dB(A) | 3200 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | |||||||||||||
![]() |
PF92251V1-000U-A99 | - | ![]() |
5541 | 0.00000000 | Sunon Fans | MagLev® PF | Box | Obsolete | 12VDC | 70000 Hrs @ 40°C | 14 ~ 158°F (-10 ~ 70°C) | Square - 92mm L x 92mm H | Auto Restart | 6 ~ 13.8VDC | CE, CUR, TUV, UL | 2 Wire Leads | - | 25.00mm | 0.227 lb (102.97 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 50 | 4.7 W | 0.393A | 75.0 CFM (2.10m³/min) | 0.350 in H2O (87.2 Pa) | Vapo-Bearing™ | Tubeaxial | 46.0dB(A) | 4500 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | |||||||||||||||
![]() |
PF92251V3-1000U-F99 | 8.6113 | ![]() |
4522 | 0.00000000 | Sunon Fans | MagLev® PF | Bulk | Active | 12VDC | 70000 Hrs @ 40°C | 14 ~ 158°F (-10 ~ 70°C) | Square - 92mm L x 92mm H | Auto Restart, Locked Rotor Sensor | PF92251V3 | 6 ~ 13.8VDC | CE, cURus, TUV | 3 Wire Leads | - | 25.00mm | 0.234 lb (106.14 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 259-1868 | EAR99 | 8414.59.6590 | 1 | 2.76 W | 0.230A | 65.0 CFM (1.82m³/min) | 0.250 in H2O (62.3 Pa) | Vapo-Bearing™ | Tubeaxial | 41.6dB(A) | 3900 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | |||||||||||||
![]() |
PMD1209PMB1-A (2).GN.IP55 | 18.9240 | ![]() |
2967 | 0.00000000 | Sunon Fans | PMD | Bulk | Active | 12VDC | - | 14 ~ 158°F (-10 ~ 70°C) | Square - 92mm L x 92mm H | Auto Restart, Locked Rotor Protection | PMD1209 | 6 ~ 13.8VDC | CE, CUR, TUV, UL | 2 Wire Leads | IP55 - Dust Protected, Water Resistant | 38.00mm | - | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 30 | 12.5 W | 1.04A | 120.2 CFM (3.37m³/min) | 0.710 in H2O (176.9 Pa) | Ball | Tubeaxial | 57.6dB(A) | 4900 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | ||||||||||||||
![]() |
FG-8B | 0.9642 | ![]() |
3213 | 0.00000000 | Sunon Fans | - | Bulk | Active | Metal | 5 Rings | FG-8 | - | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 259-1999 | EAR99 | 8414.90.1080 | 1 | Finger Guard | 80mm Sq | |||||||||||||||||||||||||||||
![]() |
PFE0381B1-000U-A99 | 37.5300 | ![]() |
5868 | 0.00000000 | Sunon Fans | PFE | Box | Active | 12VDC | 70000 Hrs @ 40°C | 14 ~ 158°F (-10 ~ 70°C) | Square - 140mm L x 140mm H | Auto Restart | PFE0381B1 | 9 ~ 13.2VDC | CE, CUR, TUV, UL | 2 Wire Leads | - | 38.00mm | 1.1 lbs (499.0 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 12 | 20.64 W | 1.72A | 238.5 CFM (6.68m³/min) | 1.200 in H2O (298.9 Pa) | Ball | Tubeaxial | 62.0dB(A) | 5500 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | ||||||||||||||
![]() |
PMD2406PKB2-A.(2).GN | 11.8657 | ![]() |
1068 | 0.00000000 | Sunon Fans | PMD | Bulk | Active | 24VDC | - | - | Square - 60mm L x 60mm H | Auto Restart | PMD2406 | - | - | 2 Wire Leads | - | 20.00mm | - | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 30 | - | - | - | Ball | Tubeaxial | - | - | Polybutylene Terephthalate (PBT) | - | |||||||||||||||
![]() |
PMD1204PPB1-A.(2).GN | - | ![]() |
3044 | 0.00000000 | Sunon Fans | PMD | Bulk | Obsolete | 12VDC | - | 14 ~ 158°F (-10 ~ 70°C) | Square - 40mm L x 40mm H | - | 6 ~ 13.8VDC | CE, CUR, TUV, UL | 2 Wire Leads per Fan | - | 56.00mm | 0.195 lb (88.45 g) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8414.59.6590 | 200 | 16.8 W | 1.4A | 26.5 CFM (0.742m³/min) | 1.730 in H2O (430.9 Pa) | Ball | Tubeaxial (Dual) | 59.0dB(A) | 14500 Front, 9500 Rear | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | |||||||||||||||
![]() |
GF80251B1-000U-SC9 | 29.3500 | ![]() |
9883 | 0.00000000 | Sunon Fans | GF | Bulk | Active | 12VDC | 70000 Hrs @ 40°C | 14 ~ 158°F (-10 ~ 70°C) | Square - 80mm L x 80mm H | Auto Restart, PWM Control, Speed Sensor (Tach) | GF80251B1 | 10.2 ~ 13.8VDC | CE, CUR, TUV, UL | 4 Wire Leads | IP56 - Dust Protected, Water Resistant | 25.00mm | 0.231 lb (104.78 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 259-1716 | EAR99 | 8414.59.6590 | 50 | 3.96 W | 0.330A | 60.0 CFM (1.68m³/min) | 0.410 in H2O (102.1 Pa) | Ball | Tubeaxial | 47.5dB(A) | 4800 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | |||||||||||||
![]() |
EE80252B1-000U-A99 | - | ![]() |
2734 | 0.00000000 | Sunon Fans | EE | Tray | Obsolete | 24VDC | 50000 Hrs @ 40°C | 14 ~ 158°F (-10 ~ 70°C) | Square - 80mm L x 80mm H | Auto Restart | EE80252B1 | 10 ~ 27.6VDC | CE, CUR, TUV, UL | 2 Wire Leads | - | 25.00mm | 0.165 lb (74.84 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 200 | 1.8 W | 0.073A | 41.0 CFM (1.15m³/min) | 0.180 in H2O (44.8 Pa) | Ball | Tubeaxial | 33.0dB(A) | 3200 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | ||||||||||||||
KDE0505PFV2-11.MS.A.GN | - | ![]() |
2712 | 0.00000000 | Sunon Fans | MagLev® KDE | Bulk | Obsolete | 5VDC | - | 14 ~ 158°F (-10 ~ 70°C) | Square - 50mm L x 50mm H | - | 4 ~ 6VDC | CE, CUR, TUV, UL | 2 Wire Leads | - | 10.00mm | 0.046 lb (20.87 g) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8414.59.6590 | 200 | 800 mW | 0.160A | 11.0 CFM (0.308m³/min) | 0.110 in H2O (27.4 Pa) | Vapo-Bearing™ | Tubeaxial | 26.0dB(A) | 4300 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | ||||||||||||||||
![]() |
SF23092A-2092HBL.GN.I55 | 19.2583 | ![]() |
2892 | 0.00000000 | Sunon Fans | SF | Bulk | Active | 240VAC | - | 14 ~ 158°F (-10 ~ 70°C) | Square - 91.5mm L x 91.5mm H | - | SF23092 | 185 ~ 245VAC | CE, CUR, TUV, UL | 2 Wire Leads | IP55 - Dust Protected, Water Resistant | 25.50mm | 0.617 lb (280.00 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 1 | 14.00W | 0.060A | 37.0 CFM (1.04m³/min) | 0.190 in H2O (47.3 Pa) | Ball | Tubeaxial | 40.0dB(A) | 2850 RPM | Aluminum | Polybutylene Terephthalate (PBT) | ||||||||||||||
![]() |
GF92251B7-000U-AD9 | 15.2680 | ![]() |
2083 | 0.00000000 | Sunon Fans | GF | Bulk | Active | 12VDC | 70000 Hrs @ 40°C | 14 ~ 158°F (-10 ~ 70°C) | Square - 92mm L x 92mm H | Auto Restart | 4.5 ~ 13.8VDC | CE, CUR, TUV, UL | 2 Wire Leads | IP68 - Dust Tight, Waterproof | 25.00mm | - | - | 259-GF92251B7-000U-AD9 | 56 | 1.1 W | 0.091A | 39.5 CFM (1.11m³/min) | 0.100 in H2O (24.9 Pa) | Ball | Tubeaxial | 28.0dB(A) | 2400 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | |||||||||||||||||||
![]() |
PF92251B3-000U-A99 | - | ![]() |
4922 | 0.00000000 | Sunon Fans | PF | Box | Obsolete | 12VDC | 70000 Hrs @ 40°C | 14 ~ 158°F (-10 ~ 70°C) | Square - 92mm L x 92mm H | Auto Restart | PF92251B3 | 6 ~ 13.8VDC | CE, CUR, TUV, UL | 2 Wire Leads | - | 25.00mm | 0.228 lb (103.42 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 50 | 3.1 W | 0.260A | 65.0 CFM (1.82m³/min) | 0.250 in H2O (62.3 Pa) | Ball | Tubeaxial | 43.0dB(A) | 3900 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | ||||||||||||||
![]() |
PMD4807PTV3-A.GN | - | ![]() |
6420 | 0.00000000 | Sunon Fans | MagLev® PMD | Bulk | Obsolete | 48VDC | - | - | Square - 70mm L x 70mm H | Auto Restart | PMD4807 | - | - | 2 Wire Leads | - | 25.00mm | - | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 30 | 4.3 W | 0.090A | 40.0 CFM (1.12m³/min) | 0.250 in H2O (62.3 Pa) | Vapo-Bearing™ | Tubeaxial | 38.0dB(A) | 4200 RPM | Polybutylene Terephthalate (PBT) | - | ||||||||||||||
![]() |
GF80252B6-000U-AE9 | 16.0566 | ![]() |
1719 | 0.00000000 | Sunon Fans | GF | Bulk | Active | 24VDC | 70000 Hrs @ 40°C | 14 ~ 158°F (-10 ~ 70°C) | Square - 80mm L x 80mm H | Auto Restart | 8 ~ 27.6VDC | CE, CUR, TUV, UL | 2 Wire Leads | IP68 - Dust Tight, Waterproof | 25.00mm | - | - | 259-GF80252B6-000U-AE9 | 50 | 1.42 W | 0.590A | 37.0 CFM (1.04m³/min) | 0.150 in H2O (37.3 Pa) | Ball | Tubeaxial | 30.0dB(A) | 2900 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | |||||||||||||||||||
![]() |
KD1204PKB1.(2).GN | - | ![]() |
1744 | 0.00000000 | Sunon Fans | KD | Bulk | Obsolete | 12VDC | - | - | Square - 40mm L x 40mm H | - | KD1204 | - | - | 2 Wire Leads | - | 20.00mm | - | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 30 | 1 W | 0.080A | 8.9 CFM (0.249m³/min) | 0.210 in H2O (52.3 Pa) | Ball | Tubeaxial | 26.5dB(A) | 7200 RPM | Polybutylene Terephthalate (PBT) | - | ||||||||||||||
![]() |
PMD1238PQB2-A(2).F.GN | - | ![]() |
1250 | 0.00000000 | Sunon Fans | PMD | Bulk | Obsolete | 12VDC | - | 14 ~ 158°F (-10 ~ 70°C) | Square - 38mm L x 38mm H | Speed Sensor (Tach) | 6 ~ 13.8VDC | CE, CUR, TUV, UL | 3 Wire Leads | - | 28.00mm | 0.078 lb (35.38 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 30 | 2.3 W | 0.190A | 12.6 CFM (0.353m³/min) | 0.550 in H2O (137.0 Pa) | Ball | Tubeaxial | 42.0dB(A) | 10000 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | |||||||||||||||
![]() |
GB0535ADB3-8 | - | ![]() |
2326 | 0.00000000 | Sunon Fans | GB | Obsolete | 5VDC | - | 14 ~ 194°F (-10 ~ 90°C) | Square - 34.8mm L x 34.8mm H | - | 3 ~ 6VDC | CE, CUR, TUV, UL | 2 Wire Leads | - | 7.30mm | 0.026 lb (11.79 g) | download | RoHS non-compliant | Not Applicable | REACH Unaffected | EAR99 | 8414.59.6560 | 200 | 250 mW | 0.050A | 0.812 CFM (0.023m³/min) | 0.130 in H2O (32.4 Pa) | Ball | Blower | 20.0dB(A) | 5000 RPM | Aluminum | Polybutylene Terephthalate (PBT) | ||||||||||||||||
![]() |
GM0504PEV1-8.GN | - | ![]() |
4846 | 0.00000000 | Sunon Fans | MagLev® GM | Bulk | Obsolete | 5VDC | - | 14 ~ 158°F (-10 ~ 70°C) | Square - 40mm L x 40mm H | - | 3 ~ 6VDC | CE, CUR, TUV, UL | 2 Wire Leads | - | 6.90mm | 0.017 lb (7.71 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 30 | 500 mW | 0.090A | 5.9 CFM (0.165m³/min) | 0.100 in H2O (24.9 Pa) | Vapo-Bearing™ | Tubeaxial | 32.0dB(A) | 7000 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | |||||||||||||||
![]() |
PSD24H0AZBX-A (2).Z.GN.IP55 | - | ![]() |
6450 | 0.00000000 | Sunon Fans | PSD | Bulk | Obsolete | 24VDC | 50000 Hrs @ 25°C | 14 ~ 158°F (-10 ~ 70°C) | Rectangular/Rounded - 170mm L x 150mm H | Auto Restart | PSD24H | 20.4 ~ 27.6VDC | CE, cURus, TUV | 2 Wire Leads | IP55 - Dust Protected, Water Resistant | 51.00mm | - | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 30 | 55.2 W | 2.30A | 387.1 CFM (10.84m³/min) | 1.233 in H2O (307.1 Pa) | Ball | Tubeaxial | 69.0dB(A) | 5800 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | ||||||||||||||
![]() |
KD2406PTB3.13.(2).A.GN | 8.5163 | ![]() |
1478 | 0.00000000 | Sunon Fans | KD | Bulk | Active | 24VDC | - | 14 ~ 158°F (-10 ~ 70°C) | Square - 60mm L x 60mm H | Auto Restart | KD2406 | 13 ~ 27.6VDC | CE, CUR, TUV, UL | 2 Wire Leads | - | 25.00mm | - | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 30 | 1 W | 0.040A | 18.0 CFM (0.504m³/min) | 0.150 in H2O (37.3 Pa) | Ball | Tubeaxial | 26.0dB(A) | 3500 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | ||||||||||||||
![]() |
PMD4806PTVX-A.U.GN | - | ![]() |
5076 | 0.00000000 | Sunon Fans | MagLev® PMD | Bulk | Obsolete | 48VDC | - | - | Square - 60mm L x 60mm H | Auto Restart | PMD4806 | - | - | 2 Wire Leads | - | 25.00mm | - | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 30 | 5.5 W | 0.114A | 40.0 CFM (1.12m³/min) | 0.640 in H2O (159.4 Pa) | Vapo-Bearing™ | Tubeaxial | 45.0dB(A) | 7600 RPM | Polybutylene Terephthalate (PBT) | - | ||||||||||||||
![]() |
A2175-HBL.T.GN | 26.0370 | ![]() |
9443 | 0.00000000 | Sunon Fans | A | Bulk | Active | 240VAC | - | - | Rectangular/Rounded - 171.5mm L x 151.5mm H | - | A2175 | - | CE, CUR, TUV, UL | 2 Wire Leads | - | 51.00mm | 2.1 lbs (952.5 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 1 | 36.00W | 0.240A | 200.0 CFM (5.60m³/min) | 0.380 in H2O (94.6 Pa) | Ball | Tubeaxial | 55.0dB(A) | 2950 RPM | Aluminum | - | ||||||||||||||
![]() |
EE80252BX-000U-G99 | 7.7912 | ![]() |
6948 | 0.00000000 | Sunon Fans | EE | Bulk | Active | 24VDC | 50000 Hrs @ 40°C | 14 ~ 158°F (-10 ~ 70°C) | Square - 80mm L x 80mm H | Auto Restart, Speed Sensor (Tach) | EE80252BX | 10 ~ 27.6VDC | CE, CUR, TUV, UL | 3 Wire Leads | - | 25.00mm | 0.196 lb (88.9 g) | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 1 | 1.9 W | 0.080A | 45.0 CFM (1.26m³/min) | 0.230 in H2O (57.3 Pa) | Ball | Tubeaxial | 38.0dB(A) | 3600 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | ||||||||||||||
![]() |
MC30060V1-000U-G99 | - | ![]() |
3232 | 0.00000000 | Sunon Fans | MagLev® MC | Box | Obsolete | 5VDC | 60000 Hrs @ 40°C | 14 ~ 158°F (-10 ~ 70°C) | Square - 30mm L x 30mm H | Auto Restart, Speed Sensor (Tach) | 2.5 ~ 6VDC | CE, CUR, TUV, UL | 3 Wire Leads | - | 6.90mm | 0.013 lb (5.9 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 259-1701 | EAR99 | 8414.59.6590 | 1 | 560 mW | 0.112A | 4.9 CFM (0.137m³/min) | 0.140 in H2O (34.9 Pa) | Vapo-Bearing™ | Tubeaxial | 28.0dB(A) | 9500 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | ||||||||||||||
![]() |
A45-10 | 1.5287 | ![]() |
5189 | 0.00000000 | Sunon Fans | - | Bulk | Active | - | - | 40.0" (1.02m) | - | - | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8544.42.9090 | 30 | - | - | - | - | - | ||||||||||||||||||||||||||
![]() |
A1123-HST.(7).GN | 20.1263 | ![]() |
8913 | 0.00000000 | Sunon Fans | A | Bulk | Active | 115VAC | - | - | Square - 119.5mm L x 119.5mm H | - | A1123 | - | CE, CUR, TUV, UL | 2 Terminals | - | 38.50mm | 1.2 lbs (544.3 g) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8414.59.6590 | 1 | 21.00W | 0.250A | 123.9 CFM (3.47m³/min) | 0.280 in H2O (69.7 Pa) | Sleeve | Tubeaxial | 46.0dB(A) | 2750 RPM | Aluminum | - | ||||||||||||||
GM0502PEV2-8.N.GN | - | ![]() |
6557 | 0.00000000 | Sunon Fans | MagLev® GM | Bulk | Obsolete | 5VDC | - | 14 ~ 158°F (-10 ~ 70°C) | Square - 25mm L x 25mm H | - | 3 ~ 6VDC | CE, CUR, TUV, UL | 2 Wire Leads | - | 6.90mm | 0.011 lb (4.99 g) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8414.59.6590 | 200 | 400 mW | 0.080A | 2.2 CFM (0.061m³/min) | 0.160 in H2O (39.8 Pa) | Vapo-Bearing™ | Tubeaxial | 23.0dB(A) | 10000 RPM | Polybutylene Terephthalate (PBT) | Polybutylene Terephthalate (PBT) | ||||||||||||||||
![]() |
A1259HBT-TC.GN | - | ![]() |
9520 | 0.00000000 | Sunon Fans | A | Obsolete | 115VAC | - | 14 ~ 176°F (-10 ~ 80°C) | Round - 254mm Dia | - | 80 ~ 125VAC | - | 2 Terminals | - | 89.00mm | 5.1 lbs (2.3 kg) | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8414.59.6590 | 12 | 72.0W | 0.600A | 585.0 CFM (16.38m³/min) | 0.310 in H2O (77.2 Pa) | Ball | Tubeaxial | 60.0dB(A) | 1900 RPM | Aluminum | - |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse