Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Mounting Type | Base Product Number | Approval Agency | Termination Style | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Configuration | Filter Type | Current | Inductance | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Frequency - Operating | Voltage - Rated DC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
AMDB3600ZC000 | 37.4900 | ![]() |
18 | 0.00000000 | KEMET | FA | Bulk | Active | -25°C ~ 85°C | General Purpose | Chassis Mount | AMDB360 | CSA, ENEC, UR | Quick Connect | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8532.25.0070 | 18 | Single Stage | Single Phase | 16 A | 1mH | 250V | 50/60Hz | - | ||||
![]() |
LF-350KA | - | ![]() |
9327 | 0.00000000 | KEMET | LF | Box | Active | -25°C ~ 55°C | General Purpose | Chassis Mount | LF-350K | - | Threaded Post (M6) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 1 | Single Stage | Three Phase (Delta) | 50 A | - | 250V | 200 V | 200 V | - | 250V | ||
![]() |
FLLE2003ARDD | 22.3617 | ![]() |
9537 | 0.00000000 | KEMET | FLLE2-R | Bulk | Active | -25°C ~ 100°C | General Purpose | Chassis Mount | FLLE2 | ENEC, UR | Wire Leads | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2003ARDD | EAR99 | 8548.00.0000 | 18 | Two Stage | Single Phase | 3 A | 2.5mH | 300V | 50/60Hz | 300V | |||
![]() |
LLD31K6APVI1 | - | ![]() |
1844 | 0.00000000 | KEMET | * | Bulk | Active | - | RoHS non-compliant | Vendor Undefined | REACH info available upon request | 2266-LLD31K6APVI1 | EAR99 | 8536.30.1000 | 1 | ||||||||||||||||
![]() |
FLLE2010AUMD | 45.9150 | ![]() |
8419 | 0.00000000 | KEMET | FLLE2-U | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Wire Leads | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2010AUMD | EAR99 | 8548.00.0000 | 12 | Two Stage | Single Phase | 10 A | 8mH | 300V | 50/60Hz | 300V | |||
![]() |
FLLE2010APDD | 23.7804 | ![]() |
5339 | 0.00000000 | KEMET | FLLE2-P | Bulk | Active | -25°C ~ 100°C | General Purpose | Chassis Mount | FLLE2 | ENEC, UR | Wire Leads | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2010APDD | EAR99 | 8548.00.0000 | 24 | Single Stage | Single Phase | 10 A | 1mH | 300V | 50/60Hz | 300V | |||
MR-2032 | 16.7400 | ![]() |
6154 | 0.00000000 | KEMET | MR | Box | Active | -20°C ~ 60°C | General Purpose | Chassis Mount | CSA, UL | Quick Connect | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8548.00.0000 | 100 | Single Stage | Single Phase | 3 A | - | 250V | - | 250V | ||||||
![]() |
FLLE2016APMB | 28.9100 | ![]() |
6783 | 0.00000000 | KEMET | FLLE2-P | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Quick Connect | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2016APMB | EAR99 | 8548.00.0000 | 18 | Single Stage | Single Phase | 16 A | 800µH | 300V | 50/60Hz | 300V | |||
![]() |
FLLD3250APZI1 | 683.7300 | ![]() |
4693 | 0.00000000 | KEMET | FLLD3 – PH | Bulk | Active | -40°C ~ 100°C | General Purpose | Chassis Mount | UL | Terminal Block | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8548.00.0000 | 1 | Two Stage | Three Phase (Delta) | 250 A | - | - | 400 V | 690 V | 50 ~ 60Hz | - | |||
MA-2053 | 17.9500 | ![]() |
2677 | 0.00000000 | KEMET | MA | Box | Active | -25°C ~ 55°C | General Purpose | Through Hole | CSA, TUV, UL | PC Pins | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8548.00.0000 | 50 | Single Stage | Single Phase | 5 A | - | 250V | - | 250V | ||||||
![]() |
FLLE2016APDD | 28.2017 | ![]() |
3047 | 0.00000000 | KEMET | FLLE2-P | Bulk | Active | -25°C ~ 100°C | General Purpose | Chassis Mount | FLLE2 | ENEC, UR | Wire Leads | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2016APDD | EAR99 | 8548.00.0000 | 18 | Single Stage | Single Phase | 16 A | 800µH | 300V | 50/60Hz | 300V | |||
![]() |
FLLE2025AUMD | 60.7008 | ![]() |
3722 | 0.00000000 | KEMET | FLLE2-U | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Wire Leads | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2025AUMD | EAR99 | 8548.00.0000 | 12 | Two Stage | Single Phase | 25 A | 2.7mH | 300V | 50/60Hz | 300V | |||
LF-215F | 75.5680 | ![]() |
8418 | 0.00000000 | KEMET | LF | Bulk | Active | -20°C ~ 55°C | General Purpose | Chassis Mount | - | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 5 | Two Stage | Single Phase | 15 A | - | 250V | - | 250V | ||||||
LF-215U | 112.6300 | ![]() |
8638 | 0.00000000 | KEMET | LF | Box | Active | -20°C ~ 55°C | General Purpose | Chassis Mount | UL | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8548.00.0000 | 15 | Two Stage | Single Phase | 15 A | - | 250V | - | 250V | ||||||
![]() |
UNFGF205UXXXXX | - | ![]() |
9929 | 0.00000000 | KEMET | * | Tray | Active | - | RoHS Compliant | 2266-UNFGF205UXXXXX | EAR99 | 8543.90.6800 | 1 | ||||||||||||||||||
![]() |
FLLE2003APMD | 19.1346 | ![]() |
8212 | 0.00000000 | KEMET | FLLE2-P | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Wire Leads | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2003APMD | EAR99 | 8548.00.0000 | 24 | Single Stage | Single Phase | 3 A | 2.5mH | 300V | 50/60Hz | 300V | |||
GT-20301 | 50.0000 | ![]() |
30 | 0.00000000 | KEMET | GT | Box | Active | -25°C ~ 55°C | General Purpose | Chassis Mount | GT-2030 | CSA, TUV, UL | Quick Connect | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8548.00.0000 | 30 | Single Stage | Single Phase | 3 A | - | 250V | - | - | |||||
![]() |
LF-220 | - | ![]() |
9041 | 0.00000000 | KEMET | LF | Box | Active | -20°C ~ 55°C | General Purpose | Chassis Mount | - | Threaded Post (M6) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 4 | Single Stage | Single Phase | 20 A | - | 250V | - | 250V | |||||
LF-250 | 393.8480 | ![]() |
8399 | 0.00000000 | KEMET | LF | Box | Active | -20°C ~ 45°C | General Purpose | Chassis Mount | - | Threaded Post (M6) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 5 | Two Stage | Single Phase | 50 A | - | 250V | - | 250V | ||||||
![]() |
FLLE2016AUMD | 49.1867 | ![]() |
3509 | 0.00000000 | KEMET | FLLE2-U | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Wire Leads | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2016AUMD | EAR99 | 8548.00.0000 | 12 | Two Stage | Single Phase | 16 A | 4mH | 300V | 50/60Hz | 300V | |||
![]() |
FAHDA3100ZA000 | - | ![]() |
8220 | 0.00000000 | KEMET | FA | Bulk | Obsolete | -25°C ~ 85°C | General Purpose | Chassis Mount | - | Quick Connect | - | EAR99 | 8548.00.0000 | 80 | Single Stage | Single Phase | 500 mA | 40mH | 250V | 50 ~ 60Hz | - | ||||||||
![]() |
FLLE2013ASMD | 42.8850 | ![]() |
5825 | 0.00000000 | KEMET | FLLE2-S | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Wire Leads | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2013ASMD | EAR99 | 8548.00.0000 | 12 | Two Stage | Single Phase | 13 A | 4mH | 300V | 50/60Hz | 300V | |||
![]() |
LH-3304 | - | ![]() |
3800 | 0.00000000 | KEMET | LH | Box | Active | -25°C ~ 55°C | General Purpose | Chassis Mount | TUV | Terminal Block | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 1 | Two Stage | Three Phase (Delta) | 30 A | - | 250V | - | 250V | |||||
![]() |
MR-2054 | - | ![]() |
7821 | 0.00000000 | KEMET | MR | Box | Active | -20°C ~ 60°C | General Purpose | Chassis Mount | - | Quick Connect | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 20 | Single Stage | Single Phase | 5 A | - | 250V | - | 250V | |||||
LF-315 | 184.3514 | ![]() |
8310 | 0.00000000 | KEMET | LF | Box | Active | -20°C ~ 55°C | General Purpose | Chassis Mount | - | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 7 | Two Stage | Three Phase (Delta) | 15 A | - | 250V | - | 250V | ||||||
![]() |
FLLD4200ATHT7 | 791.6400 | ![]() |
8128 | 0.00000000 | KEMET | FLLD3 | Bulk | Active | -25°C ~ 100°C | General Purpose | Chassis Mount | FLLD4 | ENEC, UL | Terminal Block | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8548.00.0000 | 1 | Single Stage | Three Phase (Wye) | 200 A | - | - | 305 V | 530 V | 50/60Hz | - | ||
![]() |
LF-310KA | - | ![]() |
2185 | 0.00000000 | KEMET | LF | Box | Active | -25°C ~ 55°C | General Purpose | Chassis Mount | LF-310K | - | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 1 | Single Stage | Three Phase (Delta) | 10 A | - | 250V | 200 V | 200 V | - | 250V | ||
FLLE2400APVI1 | 696.9400 | ![]() |
5981 | 0.00000000 | KEMET | FLLE2-PV | Bulk | Active | -40°C ~ 100°C | Photovoltaic Inverter | Chassis Mount | FLLE2 | EN, UL | Terminal Post | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 1 | Single Stage | DC | 400 A | - | - | - | 1200V (1.2kV) | |||||
LF-330 | 319.7443 | ![]() |
9783 | 0.00000000 | KEMET | LF | Box | Active | -20°C ~ 55°C | General Purpose | Chassis Mount | - | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Affected | EAR99 | 8536.30.8000 | 1 | Two Stage | Three Phase (Delta) | 30 A | - | 250V | - | 250V | ||||||
![]() |
FAHDA3100ZD000 | - | ![]() |
1218 | 0.00000000 | KEMET | FA | Bulk | Obsolete | -25°C ~ 85°C | General Purpose | Chassis Mount | - | Quick Connect | - | EAR99 | 8548.00.0000 | 80 | Single Stage | Single Phase | 2.5 A | 2mH | 250V | 50 ~ 60Hz | - |