Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Mounting Type | Base Product Number | Approval Agency | Termination Style | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Configuration | Filter Type | Current | Inductance | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Frequency - Operating | Voltage - Rated DC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
LF-250P | 312.8760 | ![]() |
9739 | 0.00000000 | KEMET | LF | Box | Active | -20°C ~ 45°C | General Purpose | Chassis Mount | - | Threaded Post (M6) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 5 | Two Stage | Single Phase | 50 A | - | 250V | - | 250V | |||||
![]() |
FLLE2001AUMD | 24.2094 | ![]() |
9047 | 0.00000000 | KEMET | FLLE2-U | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Wire Leads | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2001AUMD | EAR99 | 8548.00.0000 | 18 | Two Stage | Single Phase | 1 A | 22mH | 300V | 50/60Hz | 300V | |||
![]() |
FLLE2010AUDB | 61.1225 | ![]() |
6912 | 0.00000000 | KEMET | FLLE2-U | Bulk | Active | -25°C ~ 100°C | General Purpose | Chassis Mount | FLLE2 | ENEC, UR | Quick Connect | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2010AUDB | EAR99 | 8548.00.0000 | 12 | Single Stage | Single Phase | 10 A | 1mH | 300V | 50/60Hz | 300V | |||
![]() |
GTX-2060-Y0X | 31.4500 | ![]() |
10 | 0.00000000 | KEMET | GTX | Box | Active | -25°C ~ 55°C | General Purpose | Chassis Mount | GTX-2060 | cUL, TUV, UL | Terminal Block | download | Not Applicable | REACH Unaffected | EAR99 | 8548.00.0000 | 30 | Single Stage | Single Phase | 6 A | 250V | 50/60Hz | 560V | ||||||
![]() |
FLLD3010AAW02 | 52.7806 | ![]() |
7369 | 0.00000000 | KEMET | FLLD3 – AW | Bulk | Active | -25°C ~ 85°C | General Purpose | Chassis Mount | UL | Quick Connect | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8548.00.0000 | 18 | Single Stage | Three Phase (Wye) | 10 A | 200µH | - | 250 V | 440 V | 50 ~ 60Hz | - | |||
LF-310 | 170.2043 | ![]() |
8891 | 0.00000000 | KEMET | LF | Box | Active | -20°C ~ 45°C | General Purpose | Chassis Mount | UL | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 7 | Two Stage | Three Phase (Delta) | 10 A | - | 250V | - | 250V | ||||||
![]() |
FLLE2016AQMB | 29.2533 | ![]() |
7356 | 0.00000000 | KEMET | FLLE2-Q | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Quick Connect | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2016AQMB | EAR99 | 8548.00.0000 | 18 | Single Stage | Single Phase | 16 A | 800µH | 300V | 50/60Hz | 300V | |||
![]() |
RG-208F2 | 36.9904 | ![]() |
6724 | 0.00000000 | KEMET | RG | Box | Active | -20°C ~ 50°C | General Purpose | Chassis Mount | RG-208F | TUV, UL | Quick Connect, Threaded Post (M8) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 25 | Single Stage | Single Phase | 8 A | - | 250V | - | 250V | ||||
![]() |
LF-305 | 115.4675 | ![]() |
8232 | 0.00000000 | KEMET | LF | Box | Active | -20°C ~ 55°C | General Purpose | Chassis Mount | - | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 16 | Two Stage | Three Phase (Delta) | 5 A | - | 250V | - | 250V | |||||
![]() |
FLLE21K0APVI1 | 1.0000 | ![]() |
3615 | 0.00000000 | KEMET | FLLE2-PV | Bulk | Active | -40°C ~ 100°C | Photovoltaic Inverter | Chassis Mount | UL | Terminal Post | download | REACH Unaffected | EAR99 | 8548.00.0000 | 1 | Single Stage | Single Phase | 1 kA | - | - | - | 1200V (1.2kV) | |||||||
![]() |
LF-3200 | - | ![]() |
9948 | 0.00000000 | KEMET | LF | Box | Active | -25°C ~ 55°C | General Purpose | Chassis Mount | TUV | Terminal Block | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 2 | Single Stage | Three Phase (Delta) | 20 A | - | 250V | - | 250V | |||||
![]() |
LF-210P | - | ![]() |
6463 | 0.00000000 | KEMET | LF | Box | Active | -20°C ~ 55°C | General Purpose | Chassis Mount | - | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 5 | Two Stage | Single Phase | 10 A | - | 250V | - | 250V | |||||
![]() |
FLLE2020AQDD | 28.8028 | ![]() |
9013 | 0.00000000 | KEMET | FLLE2-Q | Bulk | Active | -25°C ~ 100°C | General Purpose | Chassis Mount | FLLE2 | ENEC, UR | Wire Leads | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2020AQDD | EAR99 | 8548.00.0000 | 18 | Single Stage | Single Phase | 20 A | 800µH | 300V | 50/60Hz | 300V | |||
![]() |
GTX-3400-Y000 | 194.2900 | ![]() |
4 | 0.00000000 | KEMET | GTX | Bulk | Active | -25°C ~ 55°C | Inverters, Power Drive Systems | Chassis Mount | cUL, UL | Terminal Block | download | ROHS3 Compliant | Not Applicable | 399-GTX-3400-Y000 | EAR99 | 8548.00.0000 | 1 | Two Stage | Three Phase (Delta) | 40 A | - | - | 50/60Hz | 500V | |||||
![]() |
GT-210U | 53.0200 | ![]() |
37 | 0.00000000 | KEMET | GT | Box | Active | -20°C ~ 55°C | General Purpose | Chassis Mount | CSA, TUV, UL, VDE | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8548.00.0000 | 40 | Single Stage | Single Phase | 10 A | - | 250V | - | - | |||||
![]() |
FLLE2013AQMB | 26.8711 | ![]() |
2416 | 0.00000000 | KEMET | FLLE2-Q | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Quick Connect | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2013AQMB | EAR99 | 8548.00.0000 | 18 | Single Stage | Single Phase | 13 A | 800µH | 300V | 50/60Hz | 300V | |||
![]() |
FLLE2006APDB | 32.9900 | ![]() |
13 | 0.00000000 | KEMET | FLLE2-P | Bulk | Active | -25°C ~ 100°C | General Purpose | Chassis Mount | FLLE2 | ENEC, UR | Quick Connect | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2006APDB | EAR99 | 8548.00.0000 | 24 | Single Stage | Single Phase | 6 A | 1mH | 300V | 50/60Hz | 300V | |||
![]() |
FAHDA3200ZD000 | - | ![]() |
9567 | 0.00000000 | KEMET | FA | Bulk | Obsolete | -25°C ~ 85°C | General Purpose | Chassis Mount | - | Quick Connect | - | EAR99 | 8548.00.0000 | 80 | Single Stage | Single Phase | 2.5 A | 2mH | 250V | 50 ~ 60Hz | - | ||||||||
![]() |
FLLE2025APMI | 37.9456 | ![]() |
3652 | 0.00000000 | KEMET | FLLE2-P | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Threaded Post (M4) | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2025APMI | EAR99 | 8548.00.0000 | 18 | Single Stage | Single Phase | 25 A | 800µH | 300V | 50/60Hz | 300V | |||
FLLE2400APXI1 | 662.1200 | ![]() |
8056 | 0.00000000 | KEMET | FLLE2-PV | Bulk | Active | -40°C ~ 100°C | Photovoltaic Inverter | Chassis Mount | FLLE2 | EN, UL | Terminal Post | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 1 | Single Stage | DC | 400 A | - | - | - | 1200V (1.2kV) | |||||
![]() |
FLLE2032AQDD | 40.4806 | ![]() |
8070 | 0.00000000 | KEMET | FLLE2-Q | Bulk | Active | -25°C ~ 100°C | General Purpose | Chassis Mount | FLLE2 | ENEC, UR | Wire Leads | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2032AQDD | EAR99 | 8548.00.0000 | 18 | Single Stage | Single Phase | 32 A | 800µH | 300V | 50/60Hz | 300V | |||
![]() |
FLLE2001ASMB | 24.4244 | ![]() |
2682 | 0.00000000 | KEMET | FLLE2-S | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Quick Connect | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2001ASMB | EAR99 | 8548.00.0000 | 18 | Two Stage | Single Phase | 1 A | 22mH | 300V | 50/60Hz | 300V | |||
![]() |
FLLE2016AUMB | 59.7517 | ![]() |
2413 | 0.00000000 | KEMET | FLLE2-U | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Quick Connect | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2016AUMB | EAR99 | 8548.00.0000 | 12 | Two Stage | Single Phase | 16 A | 4mH | 300V | 50/60Hz | 300V | |||
VU-220F | 32.1604 | ![]() |
2593 | 0.00000000 | KEMET | VU | Bulk | Active | -25°C ~ 55°C | General Purpose | Chassis Mount | CSA, TUV, UL | Quick Connect, Threaded Post (M8) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 25 | Single Stage | Single Phase | 20 A | - | 250V | - | 250V | ||||||
![]() |
FAHAV3100ZD000 | 7.9003 | ![]() |
9840 | 0.00000000 | KEMET | FA | Bulk | Active | -25°C ~ 85°C | General Purpose | Through Hole | FAHAV3 | CSA, ENEC, UR, VDE | PC Pins | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8532.25.0070 | 80 | Single Stage | Single Phase | 2.5 A | 2mH | 250V | 50/60Hz | - | ||||
GT-2200 | 51.2580 | ![]() |
7820 | 0.00000000 | KEMET | GT | Box | Active | -20°C ~ 55°C | General Purpose | Chassis Mount | - | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Affected | EAR99 | 8536.30.8000 | 10 | Single Stage | Single Phase | 20 A | - | 250V | - | - | ||||||
GT-2050R | 45.2480 | ![]() |
9273 | 0.00000000 | KEMET | GT | Box | Active | -20°C ~ 55°C | General Purpose | Chassis Mount | GT-2050 | - | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 30 | Single Stage | Single Phase | 5 A | - | 250V | - | - | |||||
![]() |
FLLD31K6APZI1 | 1.0000 | ![]() |
6170 | 0.00000000 | KEMET | FLLD3 – PH | Bulk | Active | -40°C ~ 100°C | General Purpose | Chassis Mount | UL | Terminal Block | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8548.00.0000 | 1 | Two Stage | Three Phase (Delta) | 1.6 kA | - | - | 400 V | 690 V | 50 ~ 60Hz | - | |||
GT-21001V | 52.7220 | ![]() |
8065 | 0.00000000 | KEMET | GT | Box | Active | -20°C ~ 55°C | General Purpose | Chassis Mount | GT-2100 | CSA, TUV, UL | Threaded Post (M4) | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.30.8000 | 10 | Single Stage | Single Phase | 10 A | - | 250V | - | - | |||||
![]() |
FLLE2006ARMB | 28.1372 | ![]() |
6717 | 0.00000000 | KEMET | FLLE2-R | Bulk | Active | -25°C ~ 100°C | Medical | Chassis Mount | FLLE2 | ENEC, UR | Quick Connect | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 399-FLLE2006ARMB | EAR99 | 8548.00.0000 | 18 | Two Stage | Single Phase | 6 A | 1mH | 300V | 50/60Hz | 300V |