Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Mounting Type | Base Product Number | Termination Style | Voltage - Supply | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Function | Delay Time | Circuit | Contact Rating @ Voltage | Relay Type | Timing Adjustment Method | Timing Initiate Method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CFB-24A-5-0.5S | 165.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 11 Pin (Octal) | 24VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CFB-24A-5-0.5S | EAR99 | 8336.50.0000 | 1 | Off-Delay | 0.05 Sec ~ 0.5 Sec | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CSB-115A-5B-5M | 176.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 11 Pin | 115VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CSB-115A-5B-5M | EAR99 | 8336.50.0000 | 1 | One Shot | 3 Sec ~ 5 Min | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CCB-24A-5B-24H | 140.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In | 24VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CCB-24A-5B-24H | EAR99 | 8336.50.0000 | 1 | On-Delay | 14.4 Min ~ 24 Hrs | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CCB-24A-2-.5S | 114.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 8 Pin (Octal) | 24VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CCB-24A-2-.5S | EAR99 | 8336.50.0000 | 1 | On-Delay | 0.05 Sec ~ 0.5 Sec | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CFB-125D-2-0.5S | 165.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 11 Pin (Octal) | 125VDC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CFB-125D-2-0.5S | EAR99 | 8336.50.0000 | 1 | Off-Delay | 0.05 Sec ~ 0.5 Sec | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CCB-125D-1-10S | 114.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 8 Pin (Octal) | 125VDC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CCB-125D-1-10S | EAR99 | 8336.50.0000 | 1 | On-Delay | 0.1 Sec ~ 10 Sec | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Fixed | Input Voltage | ||
![]() |
CLRB-24A-2-5H-5H | 165.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 8 Pin (Octal) | 24VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CLRB-24A-2-5H-5H | EAR99 | 8336.50.0000 | 1 | Repeat Cycle | 3 Min ~ 5 Hrs | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CFB-115A-3-20M | 165.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 11 Pin (Octal) | 115VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CFB-115A-3-20M | EAR99 | 8336.50.0000 | 1 | Off-Delay | 12 Sec ~ 20 Min | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
305E-007-A-1-0-P-X | 918.3900 | ![]() |
9497 | 0.00000000 | ATC-Diversified Electronics | 305E | Box | Active | Socketable | Plug In | 120VAC | - | RoHS non-compliant | 1 (Unlimited) | Vendor Undefined | 1 | On-Delay | Fixed, 60 Sec | SPDT (1 Form C) | 10A @ 120VAC | Mechanical Relay | Hand Dial | Input Voltage | |||||
![]() |
CDB-24A-5-5H | 114.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 11 Pin (Octal) | 24VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CDB-24A-5-5H | EAR99 | 8336.50.0000 | 1 | Interval | 3 Min ~ 5 Hrs | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
3RT1926-2GC51 | 130.0800 | ![]() |
4130 | 0.00000000 | Siemens | SIRIUS | Box | Active | DIN Rail | 3RT1926 | Screw Terminal | 100 ~ 127VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1 | Star Delta Controller | 1.5 Sec ~ 30 Sec | DPST-NO (2 Form A) | 3A @ 250VAC | Solid State Relay | Screwdriver Slot | Input Voltage | ||||
![]() |
CDB-24D-5-.5S | 114.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 11 Pin (Octal) | 24VDC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CDB-24D-5-.5S | EAR99 | 8336.50.0000 | 1 | Interval | 0.05 Sec ~ 0.5 Sec | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
TDU-24-AKB | 193.0000 | ![]() |
6055 | 0.00000000 | ATC-Diversified Electronics | TDU | Box | Active | Socketable | Plug In | 24VAC/DC | - | RoHS non-compliant | 1 (Unlimited) | Vendor Undefined | 1 | Programmable (Multi-Function) | 0.15 Sec ~ 64 Min | SPDT (1 Form C) | 10A @ 250VAC/24VDC | Mechanical Relay | Hand Dial | Input Voltage | |||||
![]() |
CFB-115A-2-20S | 165.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 11 Pin (Octal) | 115VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CFB-115A-2-20S | EAR99 | 8336.50.0000 | 1 | Off-Delay | - | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CFB-24A-1B-90S | 191.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 11 Pin | 24VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CFB-24A-1B-90S | EAR99 | 8336.50.0000 | 1 | Off-Delay | - | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Fixed | Input Voltage | ||
![]() |
TUB-115V-2 | 88.0000 | ![]() |
21 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 11 Pin (Octal) | 115VAC/DC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-TUB-115V-2 | EAR99 | 8336.50.0000 | 1 | Programmable (Multi-Function) | 0.1 Sec ~ 72 Min | SPDT (1 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CDB-24A-5B-1S | 140.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In | 24VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CDB-24A-5B-1S | EAR99 | 8336.50.0000 | 1 | Interval | 0.05 Sec ~ 1 Sec | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CFB-24A-2B-5H | 191.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 11 Pin | 24VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CFB-24A-2B-5H | EAR99 | 8336.50.0000 | 1 | Off-Delay | 3 Min ~ 5 Hrs | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
H3CR-A8EAC100240DC100D5 | 185.7500 | ![]() |
14 | 0.00000000 | Omron Automation and Safety | * | Bulk | Active | - | RoHS non-compliant | Vendor Undefined | REACH info available upon request | 2266-H3CR-A8EAC100240DC100D5 | EAR99 | 1 | |||||||||||||
![]() |
CDB-24A-2-1S | 114.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 8 Pin (Octal) | 24VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CDB-24A-2-1S | EAR99 | 8336.50.0000 | 1 | Interval | 0.05 Sec ~ 1 Sec | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CDB-125D-5B-1H | 140.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In | 125VDC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CDB-125D-5B-1H | EAR99 | 8336.50.0000 | 1 | Interval | 36 Sec ~ 1 Hr | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CFB-115A-2-50M | 165.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In, 11 Pin (Octal) | 115VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CFB-115A-2-50M | EAR99 | 8336.50.0000 | 1 | Off-Delay | - | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
CDB-115A-5B-2M | 140.0000 | ![]() |
10 | 0.00000000 | R-K Electronics, Inc. | - | Bulk | Active | Socketable | Plug In | 115VAC | download | ROHS3 Compliant | 1 (Unlimited) | Vendor Undefined | 3307-CDB-115A-5B-2M | EAR99 | 8336.50.0000 | 1 | Interval | 1.2 Sec ~ 2 Min | DPDT (2 Form C) | 10A @ 120/240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
TD229-1001P | 418.2950 | ![]() |
7278 | 0.00000000 | TE Connectivity Aerospace, Defense and Marine | - | Bulk | Active | - | TD229 | - | - | - | RoHS non-compliant | 1 (Unlimited) | REACH Unaffected | 2-1617805-8 | EAR99 | 8536.41.0050 | 1 | - | - | - | - | - | - | - | |
![]() |
7012PJL | 669.4725 | ![]() |
3615 | 0.00000000 | TE Connectivity Aerospace, Defense and Marine | 7000, AGASTAT | Bulk | Active | Panel Mount | 7012 | Screw Terminal | 125VDC | download | RoHS non-compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8536.49.0075 | 1 | On-Delay | 3 Cyc ~ 120 Cyc | DPDT (2 Form C) | 10A @ 240VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
A-TB72-DD-HR1C-240V | - | ![]() |
1997 | 0.00000000 | Panasonic Industrial Automation Sales | - | Bulk | Obsolete | download | 1110-A-TB72-DD-HR1C-240V | 1 | |||||||||||||||||
![]() |
A-TB72-DD-HR1C-200V | - | ![]() |
1759 | 0.00000000 | Panasonic Industrial Automation Sales | - | Bulk | Obsolete | download | 1110-A-TB72-DD-HR1C-200V | 1 | |||||||||||||||||
![]() |
AT8PSN-7 | 68.0000 | ![]() |
3 | 0.00000000 | Autonics | AT8P | Box | Active | Panel Mount | AT8PS | Plug In, 8 Pin (Octal) | 100 ~ 110VDC | download | ROHS3 Compliant | 1 (Unlimited) | 2371-AT8PSN-7 | EAR99 | 9032.89.6075 | 1 | Off-Delay | 0.05 Sec ~ 10 Sec | DPDT (2 Form C) | 3A @ 250VAC | Hand Dial | ||||
![]() |
TDT-240-AKA-060 | 202.9900 | ![]() |
6 | 0.00000000 | Mueller Electric Co | TDT | Box | Discontinued at SIC | Socketable | Plug In, 8 Pin (Octal) | 208 ~ 240VAC/DC | download | Request inventory verification | 1 (Unlimited) | Vendor Undefined | 314-TDT-240-AKA-060 | EAR99 | 9107.00.8000 | 1 | Off-Delay | 0.6 Sec ~ 60 Sec | DPDT (2 Form C) | 10A @ 250VAC | Mechanical Relay | Hand Dial | Input Voltage | ||
![]() |
TUC-120-AKA-300 | - | ![]() |
4576 | 0.00000000 | Mueller Electric Co | TUC | Box | Discontinued at SIC | Socketable | Plug In, 8 Pin (Octal) | 110 ~ 120VAC/DC | download | ROHS3 Compliant | 1 (Unlimited) | 314-TUC-120-AKA-300 | EAR99 | 9106.90.8500 | 1 | On-Delay | 3 Sec ~ 300 Sec | DPDT (2 Form C) | 10A @ 250VAC/24VDC | Mechanical Relay | Hand Dial | Input Voltage |