SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Voltage - Input (Max) DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Isolation
VI-BWN-IV-F2 Vicor Corporation VI-BWN-IV-F2 -
RFQ
ECAD 7540 0.00000000 Vicor Corporation VI-200™ (150W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-BWN 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 150 W 1 8.11A 18V 90% 18.5V - - 3 kV
VI-2WM-EW-F1 Vicor Corporation VI-2WM-EW-F1 -
RFQ
ECAD 6504 0.00000000 Vicor Corporation VI-200™ (100W) Bulk Active -10°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 0.79" H (116.8mm x 47.2mm x 20.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WM 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 100 W 1 10A 18V 88% 10V - - 3 kV
VI-2WN-CY-B1 Vicor Corporation VI-2WN-CY-B1 -
RFQ
ECAD 9838 0.00000000 Vicor Corporation VI-200™ (50W) Bulk Active -25°C ~ 85°C ITE (Commercial) 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WN 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 2.7A 18V 90% 18.5V - - 3 kV
VI-2WN-MV-F4 Vicor Corporation VI-2WN-MV-F4 -
RFQ
ECAD 6634 0.00000000 Vicor Corporation VI-200™ (150W) Bulk Active -55°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WN 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 150 W 1 8.11A 18V 90% 18.5V - - 3 kV
VI-2WP-CX Vicor Corporation VI-2WP-CX -
RFQ
ECAD 7459 0.00000000 Vicor Corporation VI-200™ (75W) Bulk Obsolete -25°C ~ 85°C ITE (Commercial) 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WP 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 5.43A 18V 90% 13.8V - - 3 kV
VI-2WP-IV-F2 Vicor Corporation VI-2WP-IV-F2 -
RFQ
ECAD 3169 0.00000000 Vicor Corporation VI-200™ (150W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WP 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 150 W 1 10.87A 18V 90% 13.8V - - 3 kV
VI-2WR-EY-F4 Vicor Corporation VI-2WR-EY-F4 -
RFQ
ECAD 5941 0.00000000 Vicor Corporation VI-200™ (50W) Bulk Active -10°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WR 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 6.67A 18V 88% 7.5V - - 3 kV
VI-2WR-IX-F4 Vicor Corporation VI-2WR-IX-F4 -
RFQ
ECAD 1442 0.00000000 Vicor Corporation VI-200™ (75W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WR 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 10A 18V 90% 7.5V - - 3 kV
VE-JWP-CY-F2 Vicor Corporation VE-JWP-CY-F2 -
RFQ
ECAD 5594 0.00000000 Vicor Corporation VE-J00™ (50W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VE-JWP 36V download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 3.62A 18V 90% 13.8V - - 3 kV
VE-JWP-EY Vicor Corporation VE-JWP-EY -
RFQ
ECAD 9762 0.00000000 Vicor Corporation VE-J00™ (50W) Bulk Obsolete -10°C ~ 100°C ITE (Commercial) 2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm) Through Hole Half Brick Isolated Module OCP, SCP VE-JWP 36V download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 3.62A 18V 88% 13.8V - - 3 kV
VE-JWP-EY-F2 Vicor Corporation VE-JWP-EY-F2 -
RFQ
ECAD 8343 0.00000000 Vicor Corporation VE-J00™ (50W) Bulk Active -10°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VE-JWP 36V download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 3.62A 18V 88% 13.8V - - 3 kV
VE-JWV-CY-B1 Vicor Corporation VE-JWV-CY-B1 -
RFQ
ECAD 5581 0.00000000 Vicor Corporation VE-J00™ (50W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.36" L x 2.28" W x 1.08" H (59.9mm x 57.9mm x 27.4mm) Through Hole Half Brick Isolated Module OCP, SCP VE-JWV 36V download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 8.62A 18V 90% 5.8V - - 3 kV
VI-JWL-EX-F2 Vicor Corporation VI-JWL-EX-F2 -
RFQ
ECAD 5602 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Obsolete -10°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 2.68A 18V 88% 28V - - 3 kV
VI-JWL-EX-S Vicor Corporation VI-JWL-EX-S -
RFQ
ECAD 9770 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Obsolete -10°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.52" H (57.9mm x 45.7mm x 13.2mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWL 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 2.68A 18V 88% 28V - - 3 kV
VI-JWM-CX Vicor Corporation VI-JWM-CX -
RFQ
ECAD 3603 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Obsolete -25°C ~ 100°C ITE (Commercial) 2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWM 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 7.5A 18V 90% 10V - - 3 kV
VI-JWM-CY-F4 Vicor Corporation VI-JWM-CY-F4 -
RFQ
ECAD 9149 0.00000000 Vicor Corporation VI-J00™ (50W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWM 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 5A 18V 90% 10V - - 3 kV
VI-JWM-EW-S Vicor Corporation VI-JWM-EW-S -
RFQ
ECAD 2052 0.00000000 Vicor Corporation VI-J00™ (100W) Bulk Active -10°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.52" H (57.9mm x 45.7mm x 13.2mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWM 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 100 W 1 10A 18V 88% 10V - - 3 kV
VI-JWM-EY-F1 Vicor Corporation VI-JWM-EY-F1 -
RFQ
ECAD 4183 0.00000000 Vicor Corporation VI-J00™ (50W) Bulk Active -10°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 0.79" H (57.9mm x 47.2mm x 20.1mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWM 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 5A 18V 88% 10V - - 3 kV
VI-JWM-MW-F4 Vicor Corporation VI-JWM-MW-F4 -
RFQ
ECAD 7658 0.00000000 Vicor Corporation VI-J00™ (100W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWM 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 100 W 1 10A 18V 90% 10V - - 3 kV
VI-JWN-CZ-F2 Vicor Corporation VI-JWN-CZ-F2 -
RFQ
ECAD 1778 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JWN 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 1.35A 18V 90% 18.5V - - 3 kV
VI-2WV-CX-B1 Vicor Corporation VI-2WV-CX-B1 -
RFQ
ECAD 2899 0.00000000 Vicor Corporation VI-200™ (75W) Bulk Active -25°C ~ 85°C ITE (Commercial) 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WV 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 12.93A 18V 90% 5.8V - - 3 kV
VI-2WV-IY-S Vicor Corporation VI-2WV-IY-S -
RFQ
ECAD 8479 0.00000000 Vicor Corporation VI-200™ (50W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 1.80" W x 0.52" H (116.8mm x 45.7mm x 13.2mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WV 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 8.62A 18V 90% 5.8V - - 3 kV
VI-2WW-IV-F3 Vicor Corporation VI-2WW-IV-F3 -
RFQ
ECAD 2437 0.00000000 Vicor Corporation VI-200™ (150W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 0.79" H (116.8mm x 47.2mm x 20.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WW 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 150 W 1 27.27A 18V 90% 5.5V - - 3 kV
VI-2WW-IV-F4 Vicor Corporation VI-2WW-IV-F4 -
RFQ
ECAD 2520 0.00000000 Vicor Corporation VI-200™ (150W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WW 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 150 W 1 27.27A 18V 90% 5.5V - - 3 kV
VI-2WW-MV-F4 Vicor Corporation VI-2WW-MV-F4 -
RFQ
ECAD 1681 0.00000000 Vicor Corporation VI-200™ (150W) Bulk Active -55°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WW 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 150 W 1 27.27A 18V 90% 5.5V - - 3 kV
VI-2WW-MV-S Vicor Corporation VI-2WW-MV-S -
RFQ
ECAD 6321 0.00000000 Vicor Corporation VI-200™ (150W) Bulk Active -55°C ~ 85°C ITE (Commercial) 4.60" L x 1.80" W x 0.52" H (116.8mm x 45.7mm x 13.2mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-2WW 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 150 W 1 27.27A 18V 90% 5.5V - - 3 kV
VI-BW2-EX Vicor Corporation VI-BW2-EX -
RFQ
ECAD 3658 0.00000000 Vicor Corporation VI-200™ (75W) Bulk Active -10°C ~ 85°C ITE (Commercial) 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-BW2 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 5A 18V 88% 15V - - 3 kV
VI-JW3-MZ Vicor Corporation VI-JW3-MZ 760.5800
RFQ
ECAD 8493 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JW3 36V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 1.04A 18V 90% 24V - - 3 kV
VE-JW3-EX-B1 Vicor Corporation VE-JW3-EX-B1 522.5300
RFQ
ECAD 5484 0.00000000 Vicor Corporation VE-J00™ (75W) Bulk Active -10°C ~ 100°C ITE (Commercial) 2.36" L x 2.28" W x 1.08" H (59.9mm x 57.9mm x 27.4mm) Through Hole Half Brick Isolated Module OCP, SCP VE-JW3 36V download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 3.13A 18V 88% 24V - - 3 kV
VE-JW3-EY-B1 Vicor Corporation VE-JW3-EY-B1 -
RFQ
ECAD 4813 0.00000000 Vicor Corporation VE-J00™ (50W) Bulk Active -10°C ~ 100°C ITE (Commercial) 2.36" L x 2.28" W x 1.08" H (59.9mm x 57.9mm x 27.4mm) Through Hole Half Brick Isolated Module OCP, SCP VE-JW3 36V download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 2.08A 18V 88% 24V - - 3 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse