SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Control Features Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation Standard Number
TRN 3-4823 Traco Power TRN 3-4823 23.1500
RFQ
ECAD 5661 0.00000000 Traco Power TRN 3 (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.47" L x 0.30" W x 0.43" H (11.9mm x 7.7mm x 11.0mm) Through Hole 5-SIP Module Isolated Module SCP TRN 3 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 36V 80% 15V -15V - - 1.6 kV
TEN 40-2422N Traco Power TEN 40-2422N 78.0200
RFQ
ECAD 9215 0.00000000 Traco Power TEN 40N (40W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP, UVLO TEN 40 36V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1563 EAR99 8504.40.9580 10 40 W 2 1.67A, 1.67A 18V 89% 12V -12V - - 1.5 kV
TDR 3-0513 Traco Power TDR 3-0513 30.9790
RFQ
ECAD 7180 0.00000000 Traco Power TDR 3 (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.74" L x 0.50" W x 0.34" H (18.9mm x 12.8mm x 8.7mm) Through Hole 14-DIP Module, 7 Leads Isolated Module Remote On/Off, SCP TDR 3 9V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 1 200mA 4.5V 81% 15V - - - 1.6 kV
TEN 30-4813 Traco Power TEN 30-4813 66.7800
RFQ
ECAD 33 0.00000000 Traco Power TEN 30 (30W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 30 75V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1549 EAR99 8504.40.9580 10 30 W 1 2A 36V 91% 15V - - - 1.5 kV
TRV 2-1523M Traco Power TRV 2-1523M 22.8100
RFQ
ECAD 1930 0.00000000 Traco Power TRV 2M (2W) Tube Active -40°C ~ 95°C ITE (Commercial), Medical 0.77" L x 0.39" W x 0.49" H (19.6mm x 9.9mm x 12.5mm) Through Hole 9-SIP Module, 5 Leads Isolated Module - CB, cURus 18V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-TRV2-1523M EAR99 8504.40.9580 10 2 W 2 - 67mA, 67mA 12V 80% 15V -15V - - 7 kV 60601-1; 62368-1
THN 20-7210WIR Traco Power THN 20-7210WIR 69.6400
RFQ
ECAD 10 0.00000000 Traco Power THN 20WIR (20W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Adjustable Output, Remote On/Off THN 20 CB, cURus 160V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-THN20-7210WIR EAR99 8504.40.9580 10 18 W 1 - 5.5A 36V 88% 3.3V - - - 3 kV 50155; 62368-1
TEN 20-4822WIN Traco Power TEN 20-4822WIN 61.5300
RFQ
ECAD 9163 0.00000000 Traco Power TEN 20WIN (20W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP TEN 20 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1539 EAR99 8504.40.9580 10 20 W 2 835mA, 835mA 18V 88% 12V -12V - - 1.5 kV
TEN 60-7218WIR Traco Power TEN 60-7218WIR 130.1300
RFQ
ECAD 10 0.00000000 Traco Power TEN 60WIR (60W) Box Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 2.00" L x 1.60" W x 1.00" H (50.8mm x 40.7mm x 25.4mm) Through Hole 8-DIP Module Isolated Module Adjustable Output, Remote On/Off TEN 60 - 160V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-TEN60-7218WIR EAR99 8504.40.9580 10 60 W 1 - 1.25A 36V 91% 48V - - - 3 kV
TEN 40-11015WIRH Traco Power TEN 40-11015WIRH 89.3700
RFQ
ECAD 8 0.00000000 Traco Power TEN (40W) Tube Active -40°C ~ 70°C ITE (Commercial), Railway 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Adjustable Output, Remote On/Off CB, cURus 160V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-TEN40-11015WIRH EAR99 8504.40.9580 10 41 W 1 - 1.666A 36V 89% 24V - - - 3 kV 62368-1
THM 6-0510 Traco Power THM 6-0510 45.6440
RFQ
ECAD 1264 0.00000000 Traco Power THM 6 (6W) Tube Active -40°C ~ 88°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module OCP, OVP, SCP THM 6 9V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 5.9 W 1 1.8A 4.5V 81.5% 3.3V - - - 5 kV
TIM 2-2410SM Traco Power TIM 2-2410SM 32.0000
RFQ
ECAD 4 0.00000000 Traco Power TIM 2SM (2W) Tube Active -40°C ~ 95°C (With Derating) Medical 0.96" L x 0.57" W x 0.40" H (24.3mm x 14.4mm x 10.2mm) Surface Mount 16-SMD Module, 7 Leads Isolated Module Remote On/Off, OVP, SCP TIM 2 36V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected 1951-1938 EAR99 8504.40.9580 10 1.7 W 1 500mA 18V 75% 3.3V - - - 5 kV
TES 3-1212 Traco Power TES 3-1212 32.4740
RFQ
ECAD 3609 0.00000000 Traco Power TES 3 (3W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 1.27" L x 0.58" W x 0.40" H (32.2mm x 14.8mm x 10.2mm) Surface Mount 24-SMD Module, 12 Leads Isolated Module SCP TES 3 18V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 3 W 1 250mA 9V 82% 12V - - - 1.5 kV
TEC 3-4823 Traco Power TEC 3-4823 14.8610
RFQ
ECAD 9547 0.00000000 Traco Power TEC 3 (3W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TEC 3 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1505 EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 36V 83% 15V -15V - - 1.6 kV
TES 2-2413M Traco Power TES 2-2413M 29.8200
RFQ
ECAD 8 0.00000000 Traco Power TES 2M (2W) Tube Active -25°C ~ 80°C (With Derating) ITE (Commercial), Medical 0.94" L x 0.54" W x 0.36" H (24.0mm x 13.7mm x 9.3mm) Surface Mount 16-SMD Module, 6 Leads Isolated Module SCP TES 2 26.4V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected 1951-1903 EAR99 8504.40.9580 10 2 W 1 133mA 21.6V 66% 15V - - - 4 kV
TEL 8-2415WI Traco Power TEL 8-2415WI 24.9200
RFQ
ECAD 103 0.00000000 Traco Power TEL 8WI (8W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 0.95" L x 0.55" W x 0.33" H (24.1mm x 14.0mm x 8.5mm) Through Hole 16-DIP Module, 6 Leads Isolated Module SCP TEL 8 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 8 W 1 335mA 9V 86% 24V - - - 1.5 kV
TEL 3-0522 Traco Power TEL 3-0522 16.7600
RFQ
ECAD 27 0.00000000 Traco Power TEL 3 (3W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 1.26" L x 0.79" W x 0.40" H (32.0mm x 20.0mm x 10.2mm) Through Hole 24-DIP Module, 13 Leads Isolated Module SCP TEL 3 9V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2105 EAR99 8504.40.9580 10 3 W 2 125mA, 125mA 4.5V 74% 12V -12V - - 1.5 kV
THR 20-7215WI Traco Power THR 20-7215WI 57.5100
RFQ
ECAD 9 0.00000000 Traco Power THR 20WI (20W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.43" H (50.8mm x 25.4mm x 11.0mm) Through Hole 6-DIP Module Isolated Module Adjustable Output, Remote On/Off CB, cURus 160V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-THR20-7215WI EAR99 8504.40.9580 10 20 W 1 - 833mA 40V 86% 24V - - - 3 kV 62368-1
TEN 40-2411WIN Traco Power TEN 40-2411WIN 86.7300
RFQ
ECAD 10 0.00000000 Traco Power TEN 40WIN (40W) Tube Active -40°C ~ 75°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.43" H (50.8mm x 25.4mm x 11.0mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP TEN 40 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 1 8A 9V 90% 5V - - - 1.5 kV
TSM 1205D Traco Power TSM 1205D 11.0500
RFQ
ECAD 10 0.00000000 Traco Power TSM (1W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.60" L x 0.31" W x 0.28" H (15.2mm x 8.0mm x 7.1mm) Surface Mount 18-SMD Module, 10 Leads Isolated Module SCP TSM 1205 13.2V - download ROHS3 Compliant 3 (168 Hours) REACH Unaffected 1951-2514 EAR99 8504.40.9580 10 1 W 2 100mA, 100mA 10.8V 75% 5V -5V - - 1 kV
THM 3-0523 Traco Power THM 3-0523 44.4900
RFQ
ECAD 6 0.00000000 Traco Power THM 3 (3W) Tube Active -40°C ~ 90°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module OCP, OVP, SCP THM 3 9V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 4.5V 86% 15V -15V - - 5 kV
THM 10-4810WI Traco Power THM 10-4810WI 63.0570
RFQ
ECAD 6712 0.00000000 Traco Power THM 10WI (10W) Tube Active -40°C ~ 90°C (With Derating) Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module OCP, OVP, SCP THM 10 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 8.3 W 1 2.5A 18V 82.5% 3.3V - - - 5 kV
TEN 6-4810WIN Traco Power TEN 6-4810WIN 22.2100
RFQ
ECAD 3071 0.00000000 Traco Power TEN 6WIN (6W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, SCP TEN 6 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 4 W 1 1.2A 18V 77% 3.3V - - - 1.5 kV
THN 30-2412 Traco Power THN 30-2412 73.4400
RFQ
ECAD 481 0.00000000 Traco Power THN 30 (30W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP THN 30 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2307 EAR99 8504.40.9580 10 30 W 1 2.5A 18V 89% 12V - - - 1.5 kV
THL 3-4822WI Traco Power THL 3-4822WI 21.4540
RFQ
ECAD 1047 0.00000000 Traco Power THL 3WI (3W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 0.94" L x 0.54" W x 0.31" H (23.8mm x 13.7mm x 8.0mm) Through Hole 16-DIP Module, 7 Leads Isolated Module Remote On/Off, SCP THL 3 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 2 125mA, 125mA 18V 80% 12V -12V - - 1.5 kV
TMR 3-7215WIR Traco Power TMR 3-7215WIR 29.9000
RFQ
ECAD 3521 0.00000000 Traco Power TMR 3WIR (3W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial), Railway 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module Isolated Module Remote On/Off, SCP TMR 3 160V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2008 EAR99 8504.40.9580 10 3 W 1 125mA 43V 83% 24V - - - 3 kV
TRA 1-1211 Traco Power TRA 1-1211 6.6400
RFQ
ECAD 6923 0.00000000 Traco Power TRA 1 (1W) Tube Not For New Designs -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.24" W x 0.40" H (19.5mm x 6.1mm x 10.2mm) Through Hole 6-SIP Module, 4 Leads Isolated Module SCP TRA 1 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 1 W 1 200mA 10.8V 84% 5V - - - 1 kV
TES 1-1212 Traco Power TES 1-1212 6.9100
RFQ
ECAD 1 0.00000000 Traco Power TES 1 (1W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.54" L x 0.31" W x 0.28" H (13.7mm x 8.0mm x 7.0mm) Surface Mount 8-SMD Module, 5 Leads Isolated Module SCP TES 1 13.2V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected 1951-2732 EAR99 8504.40.9580 10 1 W 1 85mA 10.8V 79% 12V - - - 1.5 kV
THM 60-4811WI Traco Power THM 60-4811WI 165.4500
RFQ
ECAD 5 0.00000000 Traco Power THM 60WI (60W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 2.28" L x 1.45" W x 0.50" H (57.9mm x 36.8mm x 12.7mm) Through Hole Quarter Brick Isolated Module Adjustable Output, Remote On/Off CB, cURus 75V Quarter Brick - ROHS3 Compliant Not Applicable REACH Unaffected 1951-THM60-4811WI EAR99 8504.40.9580 1 61 W 1 - 12A 18V 90% 5.1V - - - 5 kV 60601-1; 62368-1
TMR 3-1222WIE Traco Power TMR 3-1222WIE 18.3100
RFQ
ECAD 20 0.00000000 Traco Power TMR 3WIE (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.37" W x 0.44" H (21.8mm x 9.3mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 2 125mA, 125mA 4.5V 80% 12V -12V - - 1.5 kV
TRN 3-2423SM Traco Power TRN 3-2423SM 25.0150
RFQ
ECAD 2484 0.00000000 Traco Power TRN 3SM (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.47" L x 0.44" W x 0.31" H (11.9mm x 11.3mm x 8.0mm) Surface Mount 7-SMD Module Isolated Module SCP TRN 3 36V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 18V 82% 15V -15V - - 1.6 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse