SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation Line Regulation Load Regulation
THN 15-2411 Traco Power THN 15-2411 40.1500
RFQ
ECAD 1 0.00000000 Traco Power THN 15 (15W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP THN 15 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1002 EAR99 8504.40.9580 10 15 W 1 3A 18V 88% 5V - - - 1.5 kV
TMA 0505S Traco Power TMA 0505S 4.7000
RFQ
ECAD 7 0.00000000 Traco Power TMA (1W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.77" L x 0.24" W x 0.40" H (19.5mm x 6.1mm x 10.2mm) Through Hole 6-SIP Module, 4 Leads Isolated Module SCP TMA 0505 5.5V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1003 EAR99 8504.40.9580 100 1 W 1 200mA 4.5V 71% 5V - - - 1 kV
TEP 100-4813 Traco Power TEP 100-4813 166.1700
RFQ
ECAD 7924 0.00000000 Traco Power TEP 100 (100W) Box Active -40°C ~ 75°C ITE (Commercial), Railway 2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO TEP 100 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 101 W 1 6.7A 36V 93% 15V - - - 2.25 kV
TEP 100-4815 Traco Power TEP 100-4815 167.7500
RFQ
ECAD 1 0.00000000 Traco Power TEP 100 (100W) Box Active -40°C ~ 75°C ITE (Commercial), Railway 2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO TEP 100 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 101 W 1 4.2A 36V 90% 24V - - - 2.25 kV
TEP 160-4818WIR Traco Power TEP 160-4818WIR 235.3500
RFQ
ECAD 8967 0.00000000 Traco Power TEP 160WIR (196W) Box Active -40°C ~ 75°C ITE (Commercial), Railway 2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP, UVLO TEP 160 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 154 W 1 3.2A 18V 91% 48V - - - 2.25 kV
THL 10-1213 Traco Power THL 10-1213 32.1890
RFQ
ECAD 6715 0.00000000 Traco Power THL 10 (10W) Box Active -40°C ~ 80°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.40" H (25.4mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module, 4 Leads Isolated Module SCP THL 10 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 10 W 1 670mA 9V 88% 15V - - - 1.5 kV
TMF 05105 Traco Power TMF 05105 32.4500
RFQ
ECAD 4 0.00000000 Traco Power TMF (5W) Box Active -25°C ~ 70°C (With Derating) Medical 1.62" L x 1.07" W x 0.75" H (41.2mm x 27.2mm x 19.1mm) Through Hole 4-DIP Module Enclosed Universal Input TMF 05 - 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 5 5 W 1 1A 77% 5V - - - - -
TMF 05115 Traco Power TMF 05115 32.4500
RFQ
ECAD 9009 0.00000000 Traco Power TMF (5W) Box Active -25°C ~ 70°C (With Derating) Medical 1.62" L x 1.07" W x 0.75" H (41.2mm x 27.2mm x 19.1mm) Through Hole 4-DIP Module Enclosed Universal Input TMF 05 - 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 5 5 W 1 333mA 82% 15V - - - - -
TMF 20115 Traco Power TMF 20115 49.4000
RFQ
ECAD 10 0.00000000 Traco Power TMF (20W) Box Active -25°C ~ 70°C (With Derating) Medical 2.15" L x 1.77" W x 0.93" H (54.7mm x 44.9mm x 23.5mm) Through Hole 4-DIP Module Enclosed Universal Input TMF 20 - 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 20 W 1 1.333A 84% 15V - - - - -
TMF 30115 Traco Power TMF 30115 54.9100
RFQ
ECAD 24 0.00000000 Traco Power TMF (30W) Box Active -25°C ~ 70°C (With Derating) Medical 2.52" L x 1.80" W x 0.93" H (64.1mm x 45.6mm x 23.5mm) Through Hole 5-DIP Module, 4 Leads Enclosed Universal Input TMF 30 - 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 30 W 1 2A 86% 15V - - - - -
TMG 07105 Traco Power TMG 07105 32.6500
RFQ
ECAD 10 0.00000000 Traco Power TMG (7W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 1.08" L x 1.08" W x 0.74" H (27.4mm x 27.4mm x 18.7mm) Through Hole 4-DIP Module Enclosed Universal Input TMG 07 CE, cURus 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 6.3 W 1 1.26A 77% 5V - - - - -
TMG 07112 Traco Power TMG 07112 32.6500
RFQ
ECAD 56 0.00000000 Traco Power TMG (7W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 1.08" L x 1.08" W x 0.74" H (27.4mm x 27.4mm x 18.7mm) Through Hole 4-DIP Module Enclosed Universal Input TMG 07 CE, cURus 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 7 W 1 583mA 80% 12V - - - - -
TMG 15115 Traco Power TMG 15115 41.2300
RFQ
ECAD 10 0.00000000 Traco Power TMG (15W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 1.62" L x 1.07" W x 0.75" H (41.2mm x 27.2mm x 19.1mm) Through Hole 4-DIP Module Enclosed Universal Input TMG 15 CE, cURus 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 15 W 1 1A 84% 15V - - - - -
TMG 50115 Traco Power TMG 50115 81.6200
RFQ
ECAD 10 0.00000000 Traco Power TMG (50W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 2.92" L x 2.13" W x 0.86" H (74.1mm x 54.1mm x 21.8mm) Through Hole 4-DIP Module Enclosed Universal Input TMG 50 CE, cURus 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 50 W 1 3.333A 87% 15V - - - - -
TML 20112 Traco Power TML 20112 56.6800
RFQ
ECAD 247 0.00000000 Traco Power TML (20W) Box Active -25°C ~ 70°C (With Derating) ITE (Commercial) 2.74" L x 1.87" W x 0.85" H (69.5mm x 47.5mm x 21.7mm) Through Hole 8-DIP Module, 5 Leads Enclosed Universal Input TML 20 CB, CE, cURus 90 ~ 264 VAC, 100 ~ 375 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 20 W 1 1.67A 84% 12V - - - - -
TML 40205 Traco Power TML 40205 88.6800
RFQ
ECAD 9977 0.00000000 Traco Power TML (40W) Box Active -40°C ~ 60°C (With Derating) ITE (Commercial) 3.52" L x 2.52" W x 0.98" H (89.5mm x 64.1mm x 25.0mm) Through Hole 8-DIP Module, 5 Leads Enclosed Universal Input TML 40 CB, CE, cURus 90 ~ 264 VAC, 100 ~ 375 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 40 W 2 4A, 4A 84% 5V - - - - -
TMLM 10103 Traco Power TMLM 10103 -
RFQ
ECAD 9224 0.00000000 Traco Power TMLM (10W) Box Obsolete -25°C ~ 60°C (With Derating) ITE (Commercial) 2.06" L x 1.07" W x 0.93" H (52.4mm x 27.2mm x 23.5mm) Through Hole 4-DIP Module Enclosed Universal Input CE, cURus 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 8.3 W 1 2.5A 74% 3.3V - - - - -
TMM 24115 Traco Power TMM 24115 68.2600
RFQ
ECAD 1307 0.00000000 Traco Power TMM 24 (24W) Box Active -40°C ~ 80°C (With Derating) Industrial, ITE (Commercial), Medical 2.91" L x 2.13" W x 0.77" H (74.0mm x 54.0mm x 19.5mm) Through Hole 6-DIP Module, 4 Leads Enclosed Universal Input TMM 24 CB, CE, cULus, cURus 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 5 24 W 1 1.6A 82% 15V - - - - 0.5%
TMM 40112 Traco Power TMM 40112 84.1600
RFQ
ECAD 15 0.00000000 Traco Power TMM 40 (40W) Box Active -40°C ~ 80°C (With Derating) Industrial, ITE (Commercial), Medical 3.50" L x 2.50" W x 1.18" H (88.9mm x 63.5mm x 30.0mm) Through Hole 7-DIP Module, 5 Leads Enclosed Universal Input TMM 40 CB, CE, cULus, cURus 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 5 40 W 1 3.33A 84% 12V - - - - -
TMP 10103 Traco Power TMP 10103 -
RFQ
ECAD 5052 0.00000000 Traco Power TMP (10W) Box Obsolete -25°C ~ 50°C ITE (Commercial) 2.52" L x 1.77" W x 0.76" H (64.0mm x 45.0mm x 19.2mm) Through Hole 5-DIP Module Enclosed Universal Input CB, CE, cULus, cURus 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 6.6 W 1 2A 70% 3.3V - - - - -
TMP 30112 Traco Power TMP 30112 60.8900
RFQ
ECAD 1198 0.00000000 Traco Power TMP (30W) Box Active -25°C ~ 70°C (With Derating) ITE (Commercial) 3.50" L x 2.50" W x 0.85" H (88.9mm x 63.5mm x 21.7mm) Through Hole 7-DIP Module, 5 Leads Enclosed Universal Input TMP 30 CB, CE, cULus, cURus 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 5 30 W 1 2.5A 80% 12V - - - - -
TMPS 03-109 Traco Power TMPS 03-109 17.7400
RFQ
ECAD 2 0.00000000 Traco Power TMPS 03 (3W) Box Active -25°C ~ 70°C (With Derating) Household Appliances, ITE (Commercial) 1.00" L x 1.00" W x 0.64" H (25.4mm x 25.4mm x 16.3mm) Through Hole 5-DIP Module Enclosed Universal Input TMPS 03 CB, CE, cURus 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 3 W 1 333mA 77% 9V - - - - -
TMSB 2-2145 Traco Power TMSB 2-2145 -
RFQ
ECAD 9655 0.00000000 Traco Power TMSB 2 (2W) Box Obsolete -30°C ~ 70°C (With Derating) Household Appliances, ITE (Commercial) 1.35" L x 1.12" W x 0.58" H (34.2mm x 28.4mm x 14.8mm) Through Hole 7-DIP Module Enclosed Universal Input CB, CE, cURus 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 2.4 W 2 143mA, 83mA 70% 14V - - - - -
TMSB 2-285 Traco Power TMSB 2-285 -
RFQ
ECAD 4537 0.00000000 Traco Power TMSB 2 (2W) Box Obsolete -30°C ~ 70°C (With Derating) Household Appliances, ITE (Commercial) 1.35" L x 1.12" W x 0.58" H (34.2mm x 28.4mm x 14.8mm) Through Hole 7-DIP Module Enclosed Universal Input CB, CE, cURus 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510 10 3.3 W 2 250mA, 250mA 69% 8V - - - - -
TSR 3-1250A Traco Power TSR 3-1250A 26.8000
RFQ
ECAD 5 0.00000000 Traco Power TSR-3 Box Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.61" L x 0.37" W x 0.24" H (15.5mm x 9.4mm x 6.2mm) Through Hole 5-SIP Module Linear Regulator Replacement Remote On/Off, SCP TSR 3 14V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 18 W 1 3A 4.5V 93% 0.59 ~ 6V - - -
TON 15-4810WI Traco Power TON 15-4810WI 51.2330
RFQ
ECAD 7891 0.00000000 Traco Power TON 15WI (15W) Tray Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 1.10" L x 0.94" W x 0.33" H (27.9mm x 23.9mm x 8.5mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP TON 15 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 13 W 1 4A 18V 85% 3.3V - - - 2.25 kV
TDL 2-0513 Traco Power TDL 2-0513 18.9500
RFQ
ECAD 4651 0.00000000 Traco Power TDL 2 (2W) Tube Not For New Designs -40°C ~ 70°C ITE (Commercial) 0.55" L x 0.55" W x 0.31" H (14.0mm x 14.0mm x 8.0mm) Through Hole 7-DIP Module, 4 Leads Isolated Module SCP TDL 2 10V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 1 134mA 4.5V 87% 15V - - - 1.5 kV
TDN 3-1222WI Traco Power TDN 3-1222WI 24.4300
RFQ
ECAD 8 0.00000000 Traco Power TDN 3WI (3W) Tube Active -40°C ~ 70°C ITE (Commercial) 0.52" L x 0.36" W x 0.40" H (13.2mm x 9.1mm x 10.2mm) Through Hole 7-DIP Module, 6 Leads Isolated Module Remote On/Off, SCP TDN 3 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 2 125mA, 125mA 4.5V 82% 12V -12V - - 1.6 kV
TDN 3-4810WI Traco Power TDN 3-4810WI 23.5100
RFQ
ECAD 10 0.00000000 Traco Power TDN 3WI (3W) Tube Active -40°C ~ 70°C ITE (Commercial) 0.52" L x 0.36" W x 0.40" H (13.2mm x 9.1mm x 10.2mm) Through Hole 7-DIP Module, 6 Leads Isolated Module Remote On/Off, SCP TDN 3 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2.3 W 1 700mA 18V 77% 3.3V - - - 1.6 kV
TDN 5-0919WI Traco Power TDN 5-0919WI 26.7620
RFQ
ECAD 5727 0.00000000 Traco Power TDN 5WI (5W) Tube Active -40°C ~ 75°C (With Derating) ITE (Commercial) 0.52" L x 0.36" W x 0.40" H (13.2mm x 9.1mm x 10.2mm) Through Hole 7-DIP Module, 6 Leads Isolated Module Remote On/Off, SCP TDN 5 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 5 W 1 555mA 4.5V 81% 9V - - - 1.6 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse