Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
RAC48-15S/OF | - | ![]() |
7943 | 0.00000000 | Recom Power | POWERLINE RAC48/OF (48W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.18" H (101.6mm x 50.8mm x 30.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 48W | 1 | 84% | 15V | - | - | - | - | - | 3 kV | 3.2 A | |||||||
![]() |
RAC60-12S/OF | - | ![]() |
9697 | 0.00000000 | Recom Power | POWERLINE RAC60 (60W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.18" H (101.6mm x 50.8mm x 30.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 60W | 1 | 83% | 12V | - | - | - | - | - | 3 kV | 5 A | |||||||
![]() |
RACM150-48S/F | - | ![]() |
4694 | 0.00000000 | Recom Power | MEDLINE RACM150 (150W) | Box | Obsolete | -25°C ~ 80°C (With Derating) | Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.2mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM150 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 10 | 150W | 1 | 91% | 48V | - | - | - | - | No | 4 kV | 3.13 A | ||||||
![]() |
RACM40-05S/OF-ST | 91.5900 | ![]() |
3656 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM40-05 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000247 | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 90% | 5V | - | - | - | - | No | 4 kV | 8 A | |||||
RAC20-24SK/W | 15.6100 | ![]() |
1 | 0.00000000 | Recom Power | POWERLINE RAC20-K | Tray | Active | -40°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial) | 2.07" L x 1.08" W x 0.91" H (52.5mm x 27.4mm x 23.0mm) | Chassis Mount | Enclosed | Universal Input | RAC20 | CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 20 | - | 1 | - | 24V | - | - | - | No | 4 kV | |||||||||
![]() |
RACM40-18SK/OF-CTN | 17.3828 | ![]() |
8511 | 0.00000000 | Recom Power | POWERLINE RACM40-K/OF (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.08" L x 1.60" W x 1.00" H (78.3mm x 40.6mm x 25.5mm) | Chassis Mount | Open Frame | Standby Output, Universal Input | RACM40-18 | CE, cURus, CSA | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 64 | 40W | 1 | 90% | 18V | - | - | - | - | - | No | 4 kV | 60601-1 | 2.222 A | ||||
![]() |
RAC20-3.3SA-ST | - | ![]() |
2619 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 20W | 1 | 75% | 3.3V | - | - | - | - | - | 3 kV | 4.5 A | |||||||
![]() |
RAC20-15SA-ST | - | ![]() |
1514 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 20W | 1 | 82% | 15V | - | - | - | - | - | 3 kV | 1.34 A | |||||||
![]() |
RAC150-48SG/ENC | 73.1300 | ![]() |
2 | 0.00000000 | Recom Power | POWERLINE RAC150-G (150W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial) | 4.13" L x 2.44" W x 1.38" H (105.0mm x 62.0mm x 35.0mm) | Chassis Mount | Enclosed, Conformal Coated | PFC, Universal Input | RAC150-48 | CB, CE, cURus, EAC | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 125W (150W Forced Air) | 1 | 91% | 48V | - | - | - | - | - | No | 3 kV | 3.125 A | |||||
![]() |
RAC05-15SK/C14 | 18.8200 | ![]() |
27 | 0.00000000 | Recom Power | POWERLINE RAC05-K/C14 (5W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 2.17" L x 1.12" W x 0.83" H (55.1mm x 28.5mm x 21.0mm) | Panel Mount | Enclosed | Universal Input | RAC05-15 | CB, CE, cURus, FCC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 5W | 1 | 81% | 15V | - | - | - | - | - | No | 3 kV | 333 mA | |||||
![]() |
RAC15-0512TA-ST | - | ![]() |
9914 | 0.00000000 | Recom Power | POWERLINE RAC15-A (15W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.09" H (111.9mm x 63.7mm x 27.6mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 15W | 3 | 68% | 5V | 12V | -12V | - | - | - | 3 kV | 2 A | 200 mA | 200 mA | |||||
![]() |
RAC10-12SA-ST | - | ![]() |
5024 | 0.00000000 | Recom Power | POWERLINE RAC10-A (10W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.06" H (96.0mm x 53.9mm x 27.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 10W | 1 | 74% | 12V | - | - | - | - | - | 3 kV | 833 mA | |||||||
![]() |
RAC30-0512TA-E-ST | - | ![]() |
1824 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 30W | 3 | 77% | 5V | 12V | -12V | - | - | - | 3 kV | 3 A | 630 mA | 630 mA | |||||
![]() |
RACM1200-48SAV/ENC/PMB | 463.7300 | ![]() |
2 | 0.00000000 | Recom Power | RACM1200-V (1200W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial), Laboratory | 8.98" L x 3.79" W x 1.57" H (228.0mm x 96.2mm x 40.0mm) | Chassis Mount | Enclosed | Adjustable Output, Baseplate, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output | CE, cURus, EAC | 80 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Affected | EAR99 | 8504.40.9540 | 1 | 1200W | 1 | 95% | 48V | - | - | - | - | - | No | 4 kV | 61010-1; 62368-1 | 25 A | |||||
![]() |
RAC15-09SB-E-ST | - | ![]() |
8901 | 0.00000000 | Recom Power | POWERLINE RAC15-B (15W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.14" H (96.0mm x 53.9mm x 29.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 15W | 1 | 80% | 9V | - | - | - | - | - | 4 kV | 1.67 A | |||||||
RACM90-15SK/OF | 32.7300 | ![]() |
9 | 0.00000000 | Recom Power | RACM90-K (90W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.26" H (101.6mm x 50.8mm x 32.0mm) | Chassis Mount | Open Frame | DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 9 | 90W | 1 | 89% | 15V | - | - | - | - | - | No | 4 kV | - | 6 A | ||||||
![]() |
RAC05-3.3SK/C14 | 18.8200 | ![]() |
29 | 0.00000000 | Recom Power | POWERLINE RAC05-K/C14 (5W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 2.17" L x 1.12" W x 0.83" H (55.1mm x 28.5mm x 21.0mm) | Panel Mount | Enclosed | Universal Input | RAC05-3.3 | CB, CE, cURus, FCC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 5W | 1 | 76% | 3.3V | - | - | - | - | - | No | 3 kV | 1.51 A | |||||
![]() |
RAC03-12SER/277 | 28.2100 | ![]() |
48 | 0.00000000 | Recom Power | POWERLINE RAC03-SER/277 (3W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.98" L x 1.98" W x 0.43" H (50.3mm x 50.3mm x 11.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC03-12 | CE, cURus | 85 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 12 | 3W | 1 | 74% | 12V | - | - | - | - | Yes | 3 kV | 250 mA | ||||||
![]() |
RAC10-3.3SA-E-ST | - | ![]() |
9078 | 0.00000000 | Recom Power | POWERLINE RAC10-A (10W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.06" H (96.0mm x 53.9mm x 27.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 10W | 1 | 65% | 3.3V | - | - | - | - | - | 3 kV | 3 A | |||||||
![]() |
RAC40-0512TA-ST | - | ![]() |
5250 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 40W | 3 | 80% | 5V | 12V | -12V | - | - | - | 4 kV | 5 A | 600 mA | 600 mA | |||||
![]() |
RAC40-12SA-ST | - | ![]() |
2749 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 2 | 40W | 1 | 83% | 12V | - | - | - | - | - | 4 kV | 3.33 A | |||||||
![]() |
RACM550-56SG/OF | 140.4400 | ![]() |
2 | 0.00000000 | Recom Power | POWERLINE RACM550-G (550W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 5.00" L x 2.99" W x 1.50" H (127.0mm x 76.0mm x 38.0mm) | Chassis Mount | Open Frame | Adjustable Output, Baseplate, Remote On/Off, Remote Sense, Universal Input | RACM550-56 | CE, cURus | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 550W | 1 | 94% | 56V | - | - | - | - | - | - | 4 kV | 9.82 A | |||||
![]() |
RACM65-12S/OF | 100.0800 | ![]() |
8841 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM65-12 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000264 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 92.5% | 12V | - | - | - | - | No | 4 kV | 5.42 A | |||||
![]() |
RACM40-36SK/OF/2X3 | 19.1733 | ![]() |
1474 | 0.00000000 | Recom Power | POWERLINE RACM40-K/OF (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.08" L x 2.09" W x 1.00" H (78.3mm x 53.0mm x 25.5mm) | Chassis Mount | Open Frame | Standby Output, Universal Input | RACM40-36 | CE, cURus, CSA | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 90% | 36V | - | - | - | - | - | No | 4 kV | 60601-1 | 1.111 A | ||||
RACM90-12SK/OF | 32.7300 | ![]() |
53 | 0.00000000 | Recom Power | RACM90-K (90W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.26" H (101.6mm x 50.8mm x 32.0mm) | Chassis Mount | Open Frame | DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 9 | 90W | 1 | 87% | 12V | - | - | - | - | - | No | 4 kV | - | 7.5 A | ||||||
![]() |
RACM90-24SK/ENC | 36.6800 | ![]() |
17 | 0.00000000 | Recom Power | RACM90-K (90W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.66" L x 2.47" W x 1.52" H (118.3mm x 62.7mm x 38.7mm) | Chassis Mount | Enclosed | Baseplate, DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 18 | 90W | 1 | 89% | 24V | - | - | - | - | - | No | 4 kV | - | 3.75 A | |||||
![]() |
REDIN45-12/NR | - | ![]() |
5491 | 0.00000000 | Recom Power | - | Box | Obsolete | download | ROHS3 Compliant | 1 (Unlimited) | OBSOLETE | 1 | ||||||||||||||||||||||||||||
![]() |
RAC15-15DA-ST | - | ![]() |
7383 | 0.00000000 | Recom Power | POWERLINE RAC15-A (15W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.09" H (111.9mm x 63.7mm x 27.6mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 15W | 2 | 65% | 15V | -15V | - | - | - | - | 3 kV | 500 mA | 500 mA | ||||||
RACM130E-12SK/ENC | 41.5500 | ![]() |
18 | 0.00000000 | Recom Power | RACM130E-K (130W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.66" L x 2.47" W x 1.52" H (118.3mm x 62.7mm x 38.7mm) | Chassis Mount | Enclosed | Baseplate, DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 18 | 130W | 1 | 86% | 12V | - | - | - | - | - | No | 4 kV | - | 10.8 A | ||||||
RACM40-48S | 94.3600 | ![]() |
2768 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM40-48 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000238 | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 93% | 48V | - | - | - | - | No | 4 kV | 840 mA |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse