Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
RAC10-24SB-E-ST | - | ![]() |
2715 | 0.00000000 | Recom Power | POWERLINE RAC10-B (10W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 10W | 1 | 80% | 24V | - | - | - | - | - | 3 kV | 417 mA | |||||||
![]() |
RAC10-3.3SB-E-ST | - | ![]() |
7135 | 0.00000000 | Recom Power | POWERLINE RAC10-B (10W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 10W | 1 | 74% | 3.3V | - | - | - | - | - | 3 kV | 2.5 A | |||||||
![]() |
RAC15-12SA-ST | - | ![]() |
10000 | 0.00000000 | Recom Power | POWERLINE RAC15-A (15W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.09" H (111.9mm x 63.7mm x 27.6mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 15W | 1 | 73% | 12V | - | - | - | - | - | 3 kV | 1.25 A | |||||||
![]() |
RAC15-24SB-ST | - | ![]() |
9017 | 0.00000000 | Recom Power | POWERLINE RAC15-B (15W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.14" H (96.0mm x 53.9mm x 29.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 5 | 15W | 1 | 83% | 24V | - | - | - | - | - | 4 kV | 625 mA | |||||||
![]() |
RAC20-0515TA-ST | - | ![]() |
9655 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 20W | 3 | 79% | 5V | 15V | -15V | - | - | - | 3 kV | 3 A | 200 mA | 200 mA | |||||
![]() |
RAC20-05SA-ST | - | ![]() |
7172 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 20W | 1 | 79% | 5V | - | - | - | - | - | 3 kV | 4 A | |||||||
![]() |
RAC20-09DA-ST | - | ![]() |
5922 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 3 | 20W | 2 | 83% | 9V | -9V | - | - | - | - | 3 kV | 1.12 A | 1.12 A | ||||||
![]() |
RAC20-12SB-ST | 94.5700 | ![]() |
3784 | 0.00000000 | Recom Power | POWERLINE RAC20-B (20W) | Box | Not For New Designs | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC20 | CE | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 20W | 1 | 83% | 12V | - | - | - | - | - | 3 kV | 1.67 A | ||||||
![]() |
RAC20-15DA-ST | - | ![]() |
6901 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 20W | 2 | 82% | 15V | -15V | - | - | - | - | 3 kV | 677 mA | 677 mA | ||||||
![]() |
RAC20-24SA-ST | - | ![]() |
2353 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 20W | 1 | 84% | 24V | - | - | - | - | - | 3 kV | 840 mA | |||||||
![]() |
RAC20-24SB-ST | - | ![]() |
7735 | 0.00000000 | Recom Power | POWERLINE RAC20-B (20W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 20W | 1 | 84% | 24V | - | - | - | - | - | 3 kV | 840 mA | |||||||
![]() |
RAC20-3.3SB-ST | - | ![]() |
3487 | 0.00000000 | Recom Power | POWERLINE RAC20-B (20W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 20W | 1 | 74% | 3.3V | - | - | - | - | - | 3 kV | 3.6 A | |||||||
![]() |
RAC30-0512DA-E-ST | - | ![]() |
6770 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -40°C ~ 70°C | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 30W | 2 | 77% | 5V | 12V | - | - | - | - | 3 kV | 3 A | 1.25 A | ||||||
![]() |
RAC30-0512DA-ST | - | ![]() |
3796 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 30W | 2 | 77% | 5V | 12V | - | - | - | - | 3 kV | 3 A | 1.25 A | ||||||
![]() |
RAC30-0515TA-E-ST | - | ![]() |
9554 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 30W | 3 | 82% | 5V | 15V | -15V | - | - | - | 3 kV | 3 A | 500 mA | 500 mA | |||||
![]() |
RAC30-05SA-E-ST | - | ![]() |
3860 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 30W | 1 | 79% | 5V | - | - | - | - | - | 3 kV | 6 A | |||||||
![]() |
RAC30-05SA-ST | - | ![]() |
4722 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 30W | 1 | 79% | 5V | - | - | - | - | - | 3 kV | 6 A | |||||||
![]() |
RAC30-15SA-ST | - | ![]() |
3148 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 30W | 1 | 82% | 15V | - | - | - | - | - | 3 kV | 2 A | |||||||
![]() |
RAC30-24SA-ST | - | ![]() |
8308 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 30W | 1 | 82% | 24V | - | - | - | - | - | 3 kV | 1.25 A | |||||||
![]() |
RAC30-3.3SA-ST | - | ![]() |
6016 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 30W | 1 | 75% | 3.3V | - | - | - | - | - | 3 kV | 6 A | |||||||
![]() |
RAC40-0512DA-ST | - | ![]() |
6849 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 40W | 2 | 80% | 5V | 12V | - | - | - | - | 4 kV | 5 A | 1.25 A | ||||||
![]() |
RAC40-0512TA-E-ST | - | ![]() |
4218 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 40W | 3 | 80% | 5V | 12V | -12V | - | - | - | 4 kV | 5 A | 600 mA | 600 mA | |||||
![]() |
RAC40-15DA-ST | - | ![]() |
4088 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 40W | 2 | 83% | 15V | -15V | - | - | - | - | 4 kV | 1.32 A | 1.32 A | ||||||
![]() |
RAC40-15SA-E-ST | - | ![]() |
3174 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 2 | 40W | 1 | 83% | 15V | - | - | - | - | - | 4 kV | 2.67 A | |||||||
![]() |
RAC20-48SK/W | 15.6100 | ![]() |
1562 | 0.00000000 | Recom Power | POWERLINE RAC20-K | Tray | Active | -40°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial) | 2.07" L x 1.08" W x 0.91" H (52.5mm x 27.4mm x 23.0mm) | Chassis Mount | Enclosed | Universal Input | RAC20 | CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 20001199 | EAR99 | 8504.40.9510 | 20 | - | 1 | - | 48V | - | - | - | - | 3 kV | |||||||
![]() |
RACM18-05SER/W | 44.5100 | ![]() |
177 | 0.00000000 | Recom Power | MEDLINE RACM18-ER/W (18W) | Box | Active | -20°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.09" L x 2.00" W x 0.98" H (53.0mm x 51.0mm x 25.0mm) | Chassis Mount | Enclosed | IP68, Universal Input | RACM18-05 | CE | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 13W | 1 | 81% | 5V | - | - | - | - | - | 4.6 kV | 2.5 A | ||||||
![]() |
RACM100-24S/OF | 164.2100 | ![]() |
10 | 0.00000000 | Recom Power | MEDLINE RACM100 (100W) | Box | Active | -25°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.44" W x 1.54" H (91.4mm x 62.0mm x 39.2mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM100-24 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6007 | 10 | 100W | 1 | 92% | 24V | - | - | - | - | No | 4 kV | 4.17 A | ||||||
![]() |
RACM100-48S/OF | 164.2100 | ![]() |
2716 | 0.00000000 | Recom Power | MEDLINE RACM100 (100W) | Box | Active | -25°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.44" W x 1.54" H (91.4mm x 62.0mm x 39.2mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM100-48 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000312 | EAR99 | 8504.40.6007 | 10 | 100W | 1 | 91% | 48V | - | - | - | - | No | 4 kV | 2.09 A | |||||
![]() |
RACM60-12SK/ENC/2X4 | 28.6400 | ![]() |
13 | 0.00000000 | Recom Power | RACM60-K (60W) | Tray | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 4.66" L x 2.47" W x 1.52" H (118.3mm x 62.7mm x 38.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CB, CE, cURus | 80 ~ 264 VAC, 80 ~ 305 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 18 | 60W | 1 | 90% | 12V | - | - | - | - | - | No | 4.8 kV | 60335-1; 60601-1; 62368-1 | 5 A | |||||
RACM90-48SK/OF | 29.9800 | ![]() |
9 | 0.00000000 | Recom Power | RACM90-K (90W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.26" H (101.6mm x 50.8mm x 32.0mm) | Chassis Mount | Open Frame | DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 | 9 | 90W | 1 | 90% | 48V | - | - | - | - | - | No | 4 kV | - | 1.87 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse