Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
RAC30-15DA-E-ST | - | ![]() |
7844 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 30W | 2 | 82% | 15V | -15V | - | - | - | - | 3 kV | 1 A | 1 A | |||||
![]() |
RACG100-48S | - | ![]() |
6672 | 0.00000000 | Recom Power | POWERLINE RACG100 (100W) | Box | Obsolete | -20°C ~ 60°C (With Derating) | ITE (Commercial) | 5.08" L x 3.86" W x 1.50" H (129.0mm x 98.0mm x 38.0mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | CE, cURus | 90 ~ 264 VAC | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 23000004 | EAR99 | 8504.40.9520 | 1 | 100W | 1 | 88% | 48V | - | - | - | - | No | 3 kV | 2.2 A | |||||
![]() |
RACM65-24S | 115.4800 | ![]() |
63 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM65-24 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93.5% | 24V | - | - | - | - | No | 4 kV | 2.71 A | |||||
RACM40-05S | 103.3900 | ![]() |
5052 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM40-05 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000243 | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 90% | 5V | - | - | - | - | No | 4 kV | 8 A | |||||
![]() |
RACM40-05S/OF | 87.9400 | ![]() |
9276 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM40-05 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000246 | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 90% | 5V | - | - | - | - | No | 4 kV | 8 A | ||||
![]() |
RACM40-24S/OF-ST | 82.5500 | ![]() |
1909 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM40-24 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000256 | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 92% | 24V | - | - | - | - | No | 4 kV | 1.67 A | ||||
![]() |
RACM65-05S/OF-ST | 110.3000 | ![]() |
8564 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM65-05 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000262 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 90% | 5V | - | - | - | - | No | 4 kV | 10 A | ||||
![]() |
RACM65-12S-ST | 119.1400 | ![]() |
7571 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM65-12 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000263 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 92.5% | 12V | - | - | - | - | No | 4 kV | 5.42 A | ||||
![]() |
RACM65-15S-ST | 119.1400 | ![]() |
7115 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM65-15 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000266 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93.5% | 15V | - | - | - | - | No | 4 kV | 4.33 A | ||||
![]() |
RACM65-15S/OF-ST | 103.6800 | ![]() |
4793 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM65-15 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000268 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93.5% | 15V | - | - | - | - | No | 4 kV | 4.33 A | ||||
![]() |
RACM65-24S/OF-ST | 98.1600 | ![]() |
7552 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM65-24 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000271 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93.5% | 24V | - | - | - | - | No | 4 kV | 2.71 A | ||||
RAC06-09SC/W | - | ![]() |
7901 | 0.00000000 | Recom Power | POWERLINE RAC06-C (6W) | Bag | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.11" L x 1.09" W x 0.62" H (53.5mm x 27.8mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 80 ~ 264 VAC, 115 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 | 20 | 6W | 1 | 78% | 9V | - | - | - | - | Yes | 3 kV | 667 mA | |||||||
RAC06-15DC/W | - | ![]() |
9419 | 0.00000000 | Recom Power | POWERLINE RAC06-C (6W) | Bag | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.11" L x 1.09" W x 0.62" H (53.5mm x 27.8mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 80 ~ 264 VAC, 115 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 | 20 | 6W | 2 | 79% | 15V | -15V | - | - | - | Yes | 3 kV | 200 mA | 200 mA | ||||||
![]() |
RACM100-48S | 172.4300 | ![]() |
14 | 0.00000000 | Recom Power | MEDLINE RACM100 (100W) | Box | Active | -25°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.44" W x 1.54" H (91.4mm x 62.0mm x 39.2mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM100-48 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 10 | 100W | 1 | 91% | 48V | - | - | - | - | No | 4 kV | 2.09 A | |||||
![]() |
RAC02-05SE/277/W | 19.5600 | ![]() |
52 | 0.00000000 | Recom Power | POWERLINE RAC02-SE/277/W (2W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.33" L x 0.96" W x 0.70" H (33.7mm x 24.4mm x 17.8mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC02-05 | CE, cURus | 85 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 30 | 2W | 1 | 70% | 5V | - | - | - | - | Yes | 3 kV | 400 mA | |||||
![]() |
RACM150-24S | 169.1000 | ![]() |
21 | 0.00000000 | Recom Power | MEDLINE RACM150 (150W) | Box | Not For New Designs | -25°C ~ 80°C (With Derating) | Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.2mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM150 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 10 | 150W | 1 | 92% | 24V | - | - | - | - | No | 4 kV | 5.6 A | |||||
![]() |
RACM100-12S/OF | 164.2100 | ![]() |
3463 | 0.00000000 | Recom Power | MEDLINE RACM100 (100W) | Box | Active | -25°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.44" W x 1.54" H (91.4mm x 62.0mm x 39.2mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM100-12 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6007 | 10 | 100W | 1 | 91% | 12V | - | - | - | - | No | 4 kV | 8.34 A | |||||
![]() |
RAC150-12SG/ENC | 73.1300 | ![]() |
57 | 0.00000000 | Recom Power | POWERLINE RAC150-G (150W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial) | 4.13" L x 2.44" W x 1.38" H (105.0mm x 62.0mm x 35.0mm) | Chassis Mount | Enclosed, Conformal Coated | PFC, Universal Input | RAC150-12 | CB, CE, cURus, EAC | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 125W (150W Forced Air) | 1 | 91% | 12V | - | - | - | - | - | No | 3 kV | 12.5 A | ||||
![]() |
RACM150-12S/F | - | ![]() |
3502 | 0.00000000 | Recom Power | MEDLINE RACM150 (150W) | Box | Obsolete | -25°C ~ 80°C (With Derating) | Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.2mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM150 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 10 | 150W | 1 | 91% | 12V | - | - | - | - | No | 4 kV | 12.5 A | |||||
![]() |
RAC05-15SK/277/W | 13.1300 | ![]() |
60 | 0.00000000 | Recom Power | POWERLINE RAC05-K/277 (5W) | Tray | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.25" L x 1.05" W x 0.86" H (31.7mm x 26.7mm x 21.8mm) | Chassis Mount | Enclosed | Universal Input | RAC05-15 | CB, CE, cURus | 85 ~ 305 VAC, 120 ~ 430 VDC | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 20001190 | EAR99 | 8504.40.9580 | 24 | 5W | 1 | 83% | 15V | - | - | - | - | No | 3 kV | 330 mA | ||||
RAC05-05SK/277/W | 13.1300 | ![]() |
2 | 0.00000000 | Recom Power | POWERLINE RAC05-K/277 | Tray | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.25" L x 1.05" W x 0.86" H (31.7mm x 26.7mm x 21.8mm) | Chassis Mount | Enclosed | Universal Input | RAC05-05 | CB, CE, cURus | 85 ~ 305 VAC, 120 ~ 430 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 | 24 | 5W | 1 | 80% | 5V | - | - | - | - | No | 3 kV | 1 A | ||||||
![]() |
RAC05-3.3SK/277/W | 13.1300 | ![]() |
981 | 0.00000000 | Recom Power | POWERLINE RAC05-K/277 (5W) | Tray | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.25" L x 1.05" W x 0.86" H (31.7mm x 26.7mm x 21.8mm) | Chassis Mount | Enclosed | Universal Input | RAC05-3.3 | CB, CE, cURus | 85 ~ 305 VAC, 120 ~ 430 VDC | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 20001187 | EAR99 | 8504.40.9580 | 24 | 5W | 1 | 77% | 3.3V | - | - | - | - | No | 3 kV | 1.51 A | ||||
![]() |
RAC05-24SK/C14 | 18.8200 | ![]() |
25 | 0.00000000 | Recom Power | POWERLINE RAC05-K/C14 (5W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 2.17" L x 1.12" W x 0.83" H (55.1mm x 28.5mm x 21.0mm) | Panel Mount | Enclosed | Universal Input | RAC05-24 | CB, CE, cURus, FCC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 5W | 1 | 84% | 24V | - | - | - | - | - | No | 3 kV | 210 mA | ||||
![]() |
RAC20-15SK/W | 15.6100 | ![]() |
2646 | 0.00000000 | Recom Power | POWERLINE RAC20-K | Tray | Active | -40°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial) | 2.07" L x 1.08" W x 0.91" H (52.5mm x 27.4mm x 23.0mm) | Chassis Mount | Enclosed | Universal Input | RAC20 | CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 20001197 | EAR99 | 8504.40.9510 | 20 | - | 1 | - | 15V | - | - | - | - | 4 kV | ||||||
![]() |
RACM550-36SG/OF | 140.4400 | ![]() |
5 | 0.00000000 | Recom Power | POWERLINE RACM550-G (550W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 5.00" L x 2.99" W x 1.50" H (127.0mm x 76.0mm x 38.0mm) | Chassis Mount | Open Frame | Adjustable Output, Baseplate, Remote On/Off, Remote Sense, Universal Input | RACM550-36 | CE, cURus | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 550W | 1 | 93% | 36V | - | - | - | - | - | - | 4 kV | 15.28 A | ||||
![]() |
RACM550-48SG/OF | 140.4400 | ![]() |
23 | 0.00000000 | Recom Power | POWERLINE RACM550-G (550W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 5.00" L x 2.99" W x 1.50" H (127.0mm x 76.0mm x 38.0mm) | Chassis Mount | Open Frame | Adjustable Output, Baseplate, Remote On/Off, Remote Sense, Universal Input | RACM550-48 | CE, cURus | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 550W | 1 | 93% | 48V | - | - | - | - | - | - | 4 kV | 11.46 A | ||||
![]() |
RACM60-15SK/OF-CTN | 19.5258 | ![]() |
7682 | 0.00000000 | Recom Power | POWERLINE RACM60-K/OF (60W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 3.09" L x 2.09" W x 1.24" H (78.4mm x 53.0mm x 31.5mm) | Chassis Mount | Open Frame | Universal Input | RACM60-15 | CB, CE, cURus | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 48 | 60W | 1 | 90% | 15V | - | - | - | - | - | No | 4 kV | 60335-1; 60601-1; 62368-1 | 4 A | |||
![]() |
RACM60-12SK/OF-CTN | 19.5258 | ![]() |
9482 | 0.00000000 | Recom Power | POWERLINE RACM60-K/OF (60W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 3.09" L x 2.09" W x 1.24" H (78.4mm x 53.0mm x 31.5mm) | Chassis Mount | Open Frame | Universal Input | RACM60-12 | CB, CE, cURus | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 48 | 60W | 1 | 90% | 12V | - | - | - | - | - | No | 4 kV | 60335-1; 60601-1; 62368-1 | 5 A | |||
![]() |
RACM90-12SK/ENC | 39.4600 | ![]() |
17 | 0.00000000 | Recom Power | RACM90-K (90W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.66" L x 2.47" W x 1.52" H (118.3mm x 62.7mm x 38.7mm) | Chassis Mount | Enclosed | Baseplate, DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 18 | 90W | 1 | 87% | 12V | - | - | - | - | - | No | 4 kV | - | 7.5 A | ||||
RACM130E-48SK/ENC | 38.6000 | ![]() |
4 | 0.00000000 | Recom Power | RACM130E-K (130W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.66" L x 2.47" W x 1.52" H (118.3mm x 62.7mm x 38.7mm) | Chassis Mount | Enclosed | Baseplate, DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 18 | 130W | 1 | 88% | 48V | - | - | - | - | - | No | 4 kV | - | 2.71 A |