Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TPI 50-124A-J | 41.6900 | ![]() |
17 | 0.00000000 | Traco Power | TPI 50A-J (50W) | Box | Active | -40°C ~ 85°C | ITE (Commercial) | 3.00" L x 1.50" W x 1.30" H (76.2mm x 38.1mm x 33.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI50-124A-J | EAR99 | 8504.40.9510 | 1 | 50W | 1 | 93% | 24V | - | - | - | - | - | No | 3 kV | 62368-1 | 2.085 A | ||||
![]() |
TPI 50-153A-J | 40.2600 | ![]() |
20 | 0.00000000 | Traco Power | TPI 50A-J (50W) | Box | Active | -40°C ~ 85°C | ITE (Commercial) | 3.00" L x 1.50" W x 1.30" H (76.2mm x 38.1mm x 33.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI50-153A-J | EAR99 | 8504.40.9510 | 1 | 50W | 1 | 92% | 53V | - | - | - | - | - | No | 3 kV | 62368-1 | 950 mA | ||||
![]() |
TPI 180-136A-M | 100.1300 | ![]() |
1866 | 0.00000000 | Traco Power | TPI 180A-M (180W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 3.00" L x 2.00" W x 1.24" H (76.2mm x 50.8mm x 31.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, PFC, Standby Output, Universal Input | CB, CE, cURus, EAC, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPI180-136A-M | EAR99 | 8504.40.9520 | 1 | 150W (180W Forced Air) | 1 | 93% | 36V | - | - | - | - | - | No | 3 kV | 62368-1 | 5 A | ||||
![]() |
TPP 65-115E-J | 75.3800 | ![]() |
10 | 0.00000000 | Traco Power | TPP 65E-J (65W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 4.30" L x 2.20" W x 1.20" H (109.2mm x 55.9mm x 30.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP65-115E-J | EAR99 | 8504.40.9520 | 1 | 65W | 1 | 94% | 15V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 4.34 A | ||||
![]() |
TXL 060-0512DI | - | ![]() |
1436 | 0.00000000 | Traco Power | TXL 060 (60W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 6.26" L x 3.74" W x 1.50" H (159.0mm x 95.0mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1215 | EAR99 | 8504.40.9520 | 5 | 60W | 2 | 84% | 5V | 12V | - | - | - | - | - | 3 kV | 8 A | 4 A | ||||
![]() |
TOP 60318 | - | ![]() |
7532 | 0.00000000 | Traco Power | TOP 60 (60W) | Box | Obsolete | -10°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.18" H (101.6mm x 50.8mm x 30.0mm) | Chassis Mount | Open Frame | Universal Input | CB, cTUVus | 90 ~ 264 VAC, 110 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TOP60318 | EAR99 | 8504.40.9520 | 2 | 72W | 3 | 88% | 5V | 24V | -12V | - | - | - | Yes | 4 kV | 6 A | 1.5 A | 500 mA | |||
![]() |
TML 30115C | - | ![]() |
6305 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 4.41" L x 2.55" W x 1.22" H (112.0mm x 64.8mm x 31.0mm) | Chassis Mount | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 100 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML30115C | EAR99 | 8504.40.9510 | 10 | 30W | 1 | 80% | 15V | - | - | - | - | - | No | 3 kV | 60950-1 | 2 A | ||||
![]() |
TPI 30-124A-JP | 29.5800 | ![]() |
12 | 0.00000000 | Traco Power | TPI 30A-J (30W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 3.34" L x 1.36" W x 0.77" H (84.8mm x 34.5mm x 19.6mm) | Chassis Mount | Open Frame | Adjustable Output, Universal Input | TPI 30 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TPI30-124A-JP | EAR99 | 8504.40.9510 | 1 | 30W (40W Forced Air) | 1 | 88% | 24V | - | - | - | - | - | No | 3 kV | 62368-1 | 1.25 A | |||
![]() |
TOP 200-148C | - | ![]() |
1212 | 0.00000000 | Traco Power | TOP 200 (200W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 5.00" L x 3.00" W x 1.34" H (127.0mm x 76.2mm x 34.0mm) | Chassis Mount | Open Frame | Universal Input | TOP 200 | CB, CE, CSAus, GS, SIQ | 85 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TOP200-148C | EAR99 | 8504.40.9530 | 10 | 202W | 1 | 95% | 48V | - | - | - | - | - | - | 3 kV | 4.2 A | ||||
![]() |
TXH 480-148 | - | ![]() |
3289 | 0.00000000 | Traco Power | TXH 480 (480W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 7.98" L x 4.19" W x 1.77" H (202.8mm x 106.5mm x 45.0mm) | Chassis Mount | Enclosed | Adjustable Output, Remote On/Off, Universal Input | CB, CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 480W | 1 | 91% | 48V | - | - | - | - | - | No | 3 kV | 10 A | ||||||
![]() |
TXL 100-0524DI | - | ![]() |
8261 | 0.00000000 | Traco Power | TXL 100 (100W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 7.80" L x 3.74" W x 1.50" H (198.1mm x 95.0mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1220 | EAR99 | 8504.40.9520 | 2 | 144W | 2 | 84% | 5V | 24V | - | - | - | - | - | 3 kV | 12 A | 3.5 A | ||||
![]() |
TXL 025-48S | 41.2800 | ![]() |
10 | 0.00000000 | Traco Power | TXL 025 (25W) | Box | Active | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 3.11" L x 2.01" W x 1.12" H (79.0mm x 51.1mm x 28.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXL 025 | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 27W | 1 | 84% | 48V | - | - | - | - | - | Yes | 3 kV | 570 mA | |||||
![]() |
TMPW 25-112-J | 33.2900 | ![]() |
48 | 0.00000000 | Traco Power | TMPW 25-J (25W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 3.48" L x 1.50" W x 0.95" H (88.4mm x 38.1mm x 24.1mm) | Chassis Mount | Enclosed | - | TMPW 25 | CB, cURus | 90 ~ 305 VAC, 100 ~ 250 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW25-112-J | EAR99 | 8504.40.9510 | 10 | 25W | 1 | 88% | 12V | - | - | - | - | - | No | 4 kV | 60335-1; 62368-1 | 2.083 A | |||
![]() |
TXL 060-3.3S | - | ![]() |
7463 | 0.00000000 | Traco Power | TXL 060 (60W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 6.26" L x 3.74" W x 1.50" H (159.0mm x 95.0mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXL 060 | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 50W | 1 | 84% | 3.3V | - | - | - | - | - | Yes | 3 kV | 15 A | |||||
![]() |
TML 30112C | - | ![]() |
8287 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 4.41" L x 2.55" W x 1.22" H (112.0mm x 64.8mm x 31.0mm) | Chassis Mount | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 100 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML30112C | EAR99 | 8504.40.9510 | 10 | 30W | 1 | 80% | 12V | - | - | - | - | - | No | 3 kV | 60950-1 | 2.5 A | ||||
![]() |
TPP 100-112 | 108.6500 | ![]() |
153 | 0.00000000 | Traco Power | TPP 100 (100W) | Box | Active | -25°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.60" L x 2.44" W x 1.54" H (91.4mm x 62.0mm x 39.1mm) | Chassis Mount | Enclosed | Adjustable Output, IP20, Universal Input | TPP 100 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1180 | EAR99 | 8504.40.9520 | 1 | 100W | 1 | 91% | 12V | - | - | - | - | - | No | 4 kV | 8.34 A | ||||
![]() |
TMT 30124C | - | ![]() |
5078 | 0.00000000 | Traco Power | TMT (30W) | Box | Obsolete | -25°C ~ 50°C (With Derating) | Industrial, ITE (Commercial), Medical | 3.78" L x 2.01" W x 1.16" H (96.0mm x 51.0mm x 29.5mm) | Chassis Mount | Enclosed | Universal Input | TMT 30124 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 85 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | TMT30124C | EAR99 | 8504.40.9510 | 5 | 30W | 1 | 83% | 24V | - | - | - | - | - | - | 4 kV | 1.25 A | ||||
![]() |
TPP 150-112A-J | 90.6600 | ![]() |
7 | 0.00000000 | Traco Power | TPP 150A-J (150W) | Box | Active | -25°C ~ 80°C (With Derating) | ITE (Commercial), Medical | 4.00" L x 2.00" W x 1.16" H (101.6mm x 50.8mm x 29.5mm) | Chassis Mount | Open Frame | Adjustable Output, PFC, Universal Input | TPP 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-2842 | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 91% | 12V | - | - | - | - | - | No | 4 kV | 12.5 A | ||||
![]() |
TPP 15-115-J | 42.3900 | ![]() |
1 | 0.00000000 | Traco Power | TPP 15-J (15W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.82" L x 1.14" W x 0.82" H (71.6mm x 28.9mm x 20.9mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TPP 15 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-2876 | EAR99 | 8504.40.9510 | 1 | 15W | 1 | 87% | 15V | - | - | - | - | - | No | 4 kV | 1 A | ||||
![]() |
TMPW 5-124-J | 19.3300 | ![]() |
10 | 0.00000000 | Traco Power | TMPW 5-J (5W) | Box | Active | -40°C ~ 70°C (With Derating) | Household Appliances, ITE (Commercial) | 2.17" L x 1.70" W x 0.91" H (55.1mm x 43.2mm x 23.1mm) | Chassis Mount | Enclosed | - | TMPW 5 | CB, cURus | 90 ~ 305 VAC, 100 ~ 250 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TMPW5-124-J | EAR99 | 8504.40.9510 | 10 | 5W | 1 | 83% | 24V | - | - | - | - | - | No | 4 kV | 60335-1; 62368-1 | 210 mA | |||
![]() |
TIW 06-105 | 45.3300 | ![]() |
6 | 0.00000000 | Traco Power | TIW (6W) | Box | Active | -25°C ~ 50°C | Household Appliances, ITE (Commercial) | 2.17" L x 0.93" W x 1.89" H (55.0mm x 23.6mm x 48.0mm) | Chassis Mount | Enclosed | IP67, Universal Input | TIW 06 | CB, CE, cCSAus | 93 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1224 | EAR99 | 8504.40.9510 | 10 | 5W | 1 | 75% | 5V | - | - | - | - | - | - | 1 A | |||||
![]() |
TPI 150-148A-J | 83.4100 | ![]() |
293 | 0.00000000 | Traco Power | TPI 150A (150W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.16" H (101.6mm x 50.8mm x 29.5mm) | Chassis Mount | Open Frame | Adjustable Output, PFC, Universal Input | TPI 150 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 92% | 48V | - | - | - | - | - | No | 3 kV | 3.13 A | |||||
![]() |
TPI 65-105A-JP | 47.5500 | ![]() |
1036 | 0.00000000 | Traco Power | TPI 65A-J (65W) | Box | Active | -40°C ~ 85°C | ITE (Commercial) | 3.00" L x 2.00" W x 0.94" H (76.2mm x 50.8mm x 23.9mm) | Chassis Mount | Open Frame | Universal Input | TPI 65 | - | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TPI65-105A-JP | EAR99 | 8504.40.9520 | 1 | 50W | 1 | 90% | 5V | - | - | - | - | - | No | 3 kV | 62368-1 | 10 A | |||
![]() |
TXLN 960-148 | 384.4000 | ![]() |
67 | 0.00000000 | Traco Power | TXLN 960 (960W) | Box | Active | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 10.83" L x 4.92" W x 2.48" H (275.0mm x 125.0mm x 63.0mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | TXLN 960 | CB, CE, cURus | 90 ~ 264 VAC, 127 ~ 375 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TXLN960-148 | EAR99 | 8504.40.9540 | 1 | 960W | 1 | 89% | 48V | - | - | - | - | - | No | 3 kV | 62368-1 | 20 A | |||
![]() |
TMP 30522C | 88.4500 | ![]() |
4 | 0.00000000 | Traco Power | TMP (30W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.41" L x 2.51" W x 1.01" H (112.0mm x 63.8mm x 25.7mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMP 30522 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 30W | 3 | 76% | 5V | 12V | -12V | - | - | - | Yes | 3 kV | 3 A | 1 A | 250 mA | |||
![]() |
TXLN 035-22M2 | 52.8600 | ![]() |
54 | 0.00000000 | Traco Power | TXLN 035 (35W) | Box | Active | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 3.90" L x 3.23" W x 1.38" H (99.0mm x 82.0mm x 35.0mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXLN 035 | CB, CE, cURus | 88 ~ 264 VAC, 125 ~ 375 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 1951-TXLN035-22M2 | EAR99 | 8504.40.9520 | 5 | 54W | 2 | 83% | 12V | -12V | - | - | - | - | Yes | 3 kV | 62368-1 | 3 A | 1.5 A | ||
![]() |
TPP 65-148E-J | 72.9400 | ![]() |
10 | 0.00000000 | Traco Power | TPP 65E-J (65W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 4.30" L x 2.20" W x 1.20" H (109.2mm x 55.9mm x 30.5mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | CB, CE, CSA, cURus, UKCA | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TPP65-148E-J | EAR99 | 8504.40.9520 | 1 | 65W | 1 | 93% | 48V | - | - | - | - | - | No | 4 kV | 60601-1; 62368-1 | 1.36 A | ||||
![]() |
TML 15105C | - | ![]() |
5554 | 0.00000000 | Traco Power | TML | Box | Obsolete | -25°C ~ 60°C (With Derating) | ITE (Commercial) | 3.78" L x 2.13" W x 1.08" H (96.0mm x 54.1mm x 27.4mm) | Chassis Mount | Enclosed | Universal Input | CE, cURus | 90 ~ 264 VAC, 85 ~ 370 VDC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-TML15105C | EAR99 | 8504.40.9510 | 10 | 15W | 1 | 80% | 5V | - | - | - | - | - | No | 3 kV | 60950-1 | 3 A | ||||
![]() |
TML 100-148C | 165.4500 | ![]() |
1 | 0.00000000 | Traco Power | TML 100C (85-100W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 5.60" L x 2.48" W x 1.46" H (142.2mm x 63.0mm x 37.1mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Remote On/Off, Universal Input | TML 100 | CB, CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 101W | 1 | 93% | 48V | - | - | - | - | - | Yes | 3 kV | 2.1 A | |||||
![]() |
TEX 120-112 | 388.1800 | ![]() |
9404 | 0.00000000 | Traco Power | TEX (120W) | Box | Active | -40°C ~ 85°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial), Laboratory | 6.85" L x 3.66" W x 2.20" H (174.0mm x 93.0mm x 55.9mm) | Chassis Mount | Enclosed | Adjustable Output, IP67, Universal Input | TEX 120 | CB, CE, cCSAus, cULus, SIQ | 85 ~ 264 VAC, 85 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 10 | 96W | 1 | - | 12V | - | - | - | - | - | - | 8 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse