SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-ABABHG-P-A-DK00000 Advanced Energy CX10S-ABABHG-P-A-DK00000 -
RFQ
ECAD 9486 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABABHG-P-A-DK00000 EAR99 8504.40.9540 1 790W 8 93% 5V 12V 5V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 21 A 15 A 6 A 3 A
NMP1K2-CCKECE-01 MEAN WELL USA Inc. NMP1K2-CCKECE-01 821.0300
RFQ
ECAD 3499 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 5V 48V 12V 5V 12V - - 4 kV 60601-1; 62368-1 72 A 5 A 20 A 36 A 20 A
CX10S-DBHAHD-P-A-DK00000 Advanced Energy CX10S-DBHAHD-P-A-DK00000 -
RFQ
ECAD 2473 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBHAHD-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 48V 12V 5V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 6 A 3 A 21 A 6 A
CX10S-BGC0BG-P-A-DK00000 Advanced Energy CX10S-BGC0BG-P-A-DK00000 -
RFQ
ECAD 2598 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BGC0BG-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 12V 24V 24V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 8.3 A 15 A 3 A
CX10S-H0CHDG-P-A-DK00000 Advanced Energy CX10S-H0CHDG-P-A-DK00000 -
RFQ
ECAD 4507 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H0CHDG-P-A-DK00000 EAR99 8504.40.9540 1 720W 8 93% 5V 24V 24V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 8.3 A 6 A 3 A 4.17 A
CX10S-DGHBHA-P-A-DK00000 Advanced Energy CX10S-DGHBHA-P-A-DK00000 -
RFQ
ECAD 8976 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGHBHA-P-A-DK00000 EAR99 8504.40.9540 1 805W 9 93% 48V 24V 24V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 6 A 3 A 15 A
CX10S-DD0GDH-P-A-DK00000 Advanced Energy CX10S-DD0GDH-P-A-DK00000 -
RFQ
ECAD 7382 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DD0GDH-P-A-DK00000 EAR99 8504.40.9540 1 820W 7 93% 48V 48V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 3 A 3 A 4.17 A 6 A
NMP1K2-#HC#HH-05 MEAN WELL USA Inc. NMP1K2-#HC#HH-05 646.1400
RFQ
ECAD 3034 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 900W 3 88.5% 24V 5V 24V - - - 4 kV 60601-1; 62368-1 10 A 36 A 20 A
CX10S-G0HBCB-P-A-DK00000 Advanced Energy CX10S-G0HBCB-P-A-DK00000 -
RFQ
ECAD 8116 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0HBCB-P-A-DK00000 EAR99 8504.40.9540 1 780W 7 93% 24V 24V 5V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 15 A 8.3 A
CX10S-C0DCDH-P-A-DK00000 Advanced Energy CX10S-C0DCDH-P-A-DK00000 -
RFQ
ECAD 4508 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0DCDH-P-A-DK00000 EAR99 8504.40.9540 1 900W 6 93% 24V 48V 24V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 8.3 A 4.17 A 6 A 3 A
NMP1K2-C##CHC-00 MEAN WELL USA Inc. NMP1K2-C##CHC-00 641.2200
RFQ
ECAD 1811 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 780W 4 88.5% 5V 5V 24V 5V - - 4 kV 60601-1; 62368-1 36 A 36 A 10 A 36 A
CX10S-DAGGGA-P-A-DK00000 Advanced Energy CX10S-DAGGGA-P-A-DK00000 -
RFQ
ECAD 6827 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DAGGGA-P-A-DK00000 EAR99 8504.40.9540 1 770W 9 93% 48V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 3 A 3 A 3 A 3 A
CX10S-HGBBAD-P-A-DK00000 Advanced Energy CX10S-HGBBAD-P-A-DK00000 -
RFQ
ECAD 5351 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGBBAD-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 5V 24V 24V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 15 A 15 A
VI-RUVNN-EVVV-CC Vicor Corporation VI-RUVNN-EVVV-CC 2.0000
RFQ
ECAD 1618 0.00000000 Vicor Corporation * Bulk Active VI-RUVNN - RoHS non-compliant 1 (Unlimited) REACH Unaffected 1
CX10S-CC0HBC-P-A-DK00000 Advanced Energy CX10S-CC0HBC-P-A-DK00000 -
RFQ
ECAD 5043 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CC0HBC-P-A-DK00000 EAR99 8504.40.9540 1 680W 6 93% 24V 24V 5V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 6 A 3 A 15 A 8.3 A
CX10S-C00ACD-P-A-DK00000 Advanced Energy CX10S-C00ACD-P-A-DK00000 -
RFQ
ECAD 1011 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C00ACD-P-A-DK00000 EAR99 8504.40.9540 1 705W 4 93% 24V 5V 24V 48V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 8.3 A 4.17 A
CX10S-BCBCHD-P-A-DK00000 Advanced Energy CX10S-BCBCHD-P-A-DK00000 -
RFQ
ECAD 7649 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCBCHD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 12V 24V 12V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 15 A 8.3 A 6 A 3 A
NMP1K2-EEKEE#-04 MEAN WELL USA Inc. NMP1K2-EEKEE#-04 733.5900
RFQ
ECAD 9999 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 4 88.5% 12V 12V 48V 12V - - 4 kV 60601-1; 62368-1 20 A 20 A 5 A 40 A
CX10S-GGGDHH-P-A-DK00000 Advanced Energy CX10S-GGGDHH-P-A-DK00000 -
RFQ
ECAD 3460 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGGDHH-P-A-DK00000 EAR99 8504.40.9540 1 760W 11 93% 24V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 3 A 3 A
NMP650-CKHK-00 MEAN WELL USA Inc. NMP650-CKHK-00 561.0400
RFQ
ECAD 3230 0.00000000 MEAN WELL USA Inc. NMP (650W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 3.50" W x 1.61" H (250.0mm x 89.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP650 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 650W 4 88.5% 5V 48V 24V 48V - - 4 kV 60601-1; 62368-1 36 A 5 A 10 A 5 A
NMP1K2-#HEKKK-09 MEAN WELL USA Inc. NMP1K2-#HEKKK-09 735.9300
RFQ
ECAD 8261 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 3 88.5% 24V 12V 48V - - - 4 kV 60601-1; 62368-1 10 A 20 A 15 A
CX10S-GGCHBD-P-A-DK00000 Advanced Energy CX10S-GGCHBD-P-A-DK00000 -
RFQ
ECAD 3534 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGCHBD-P-A-DK00000 EAR99 8504.40.9540 1 920W 9 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 8.3 A 6 A
CX10S-AAA00A-P-A-DK00000 Advanced Energy CX10S-AAA00A-P-A-DK00000 -
RFQ
ECAD 4438 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAA00A-P-A-DK00000 EAR99 8504.40.9540 1 420W 4 93% 5V 5V 5V 5V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 21 A 21 A
MAP80-4003G Bel Power Solutions MAP80-4003G 352.2900
RFQ
ECAD 7154 0.00000000 Bel Power Solutions MAP80 (80W) Bulk Active 0°C ~ 70°C (With Derating) ITE (Commercial) 7.20" L x 4.20" W x 1.80" H (182.9mm x 106.7mm x 45.7mm) Chassis Mount Open Frame Adjustable Output, Universal Input MAP80 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.7007 10 80W 4 80% 5V 15V -5V -15V - Yes 2.6 kV 14 A 4 A 1 A 1 A
CX10S-0CB0AD-P-A-DK00000 Advanced Energy CX10S-0CB0AD-P-A-DK00000 -
RFQ
ECAD 4482 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0CB0AD-P-A-DK00000 EAR99 8504.40.9540 1 685W 4 93% 24V 12V 5V 48V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 21 A 4.17 A
VI-QU4L-CQY Vicor Corporation VI-QU4L-CQY -
RFQ
ECAD 7273 0.00000000 Vicor Corporation * Bulk Obsolete VI-QU4L - 1 (Unlimited) REACH Affected EAR99 8504.40.9530 1
AC3-RMVH-00 Cosel USA, Inc. AC3-RMVH-00 563.9000
RFQ
ECAD 5545 0.00000000 Cosel USA, Inc. ACE (300W) Box Active -20°C ~ 70°C ITE (Commercial), Medical 10.00" L x 4.06" W x 2.50" H (254.0mm x 103.1mm x 63.5mm) Chassis Mount Enclosed AC3-RMVH CE, CSA, cURus, TUV, UL 85 ~ 264 VAC download ROHS3 Compliant Not Applicable EAR99 8504.40.9530 1 5 78% 24V 5V 15V -15V - No 3 kV 60601-1; 60950-1; 62368-1 2.5 A 10 A 5.5 A 7 A 6.5 A
CX10S-HDCDCH-P-A-DK00000 Advanced Energy CX10S-HDCDCH-P-A-DK00000 -
RFQ
ECAD 1355 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDCDCH-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 5V 24V 48V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 8.3 A 4.17 A 8.3 A
VI-RUF30-EWUY Vicor Corporation VI-RUF30-EWUY -
RFQ
ECAD 5692 0.00000000 Vicor Corporation * Bulk Obsolete VI-RUF30 - 1 (Unlimited) OBSOLETE 1
CX10S-0GGAAG-P-A-DK00000 Advanced Energy CX10S-0GGAAG-P-A-DK00000 -
RFQ
ECAD 2251 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GGAAG-P-A-DK00000 EAR99 8504.40.9540 1 570W 8 93% 24V 24V 24V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 21 A 21 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse