Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
WP3-779300-EL Vicor Corporation WP3-779300-EL -
RFQ
ECAD 4290 0.00000000 Vicor Corporation - Bulk Obsolete - Not Applicable 1102-WP3-779300-EL OBSOLETE 1
AME2-3.3SJZ-ST aimtec AME2-3.3SJZ-ST 17.1500
RFQ
ECAD 6237 0.00000000 aimtec AME2-JZ (2W) Box Active -25°C ~ 70°C (With Derating) ITE (Commercial) 2.99" L x 1.24" W x 1.06" H (75.9mm x 31.5mm x 26.9mm) Chassis Mount Enclosed - AME2 cURus 85 ~ 305 VAC, 120 ~ 430 VDC download ROHS3 Compliant 1 (Unlimited) 2721-AME2-3.3SJZ-ST EAR99 8504.40.9510 24 2W 1 65% 3.3V - - - - - Yes 3 kV 60950-1 600 mA
CX10S-0GGDGA-P-A-DK00000 Advanced Energy CX10S-0GGDGA-P-A-DK00000 -
RFQ
ECAD 1052 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GGDGA-P-A-DK00000 EAR99 8504.40.9540 1 665W 8 93% 24V 24V 24V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 4.17 A 3 A
CX10S-0HBBDB-P-A-DK00000 Advanced Energy CX10S-0HBBDB-P-A-DK00000 -
RFQ
ECAD 8294 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HBBDB-P-A-DK00000 EAR99 8504.40.9540 1 840W 6 93% 5V 24V 12V 12V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 15 A 4.17 A 15 A
CX10S-CAHGCH-P-A-DK00000 Advanced Energy CX10S-CAHGCH-P-A-DK00000 -
RFQ
ECAD 3950 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CAHGCH-P-A-DK00000 EAR99 8504.40.9540 1 825W 9 93% 24V 5V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 6 A 3 A 3 A 3 A
NEVO+600ML-1222-DK000 Vox Power Ltd. NEVO+600ML-1222-DK000 472.5500
RFQ
ECAD 9511 0.00000000 Vox Power Ltd. NEVO+600ML Box Active -20°C ~ 70°C Medical 5.27" L x 3.06" W x 1.61" H (133.8mm x 77.7mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input NEVO+600 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download Not Applicable REACH Unaffected 2050-NEVO+600ML-1222-DK000 EAR99 8504.40.9530 1 575W 4 86% 5V 12V 12V 12V - - No 4 kV 60601-1 25 A 15 A 15 A 15 A
CX10S-A0D0AA-P-A-DK00000 Advanced Energy CX10S-A0D0AA-P-A-DK00000 -
RFQ
ECAD 1768 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0D0AA-P-A-DK00000 EAR99 8504.40.9540 1 515W 4 93% 5V 48V 5V 5V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 21 A 21 A
CX10S-CBAB0H-P-A-DK00000 Advanced Energy CX10S-CBAB0H-P-A-DK00000 -
RFQ
ECAD 7875 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBAB0H-P-A-DK00000 EAR99 8504.40.9540 1 765W 6 93% 24V 12V 5V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 21 A 15 A 6 A 3 A
CX10S-00HHCG-P-A-DK00000 Advanced Energy CX10S-00HHCG-P-A-DK00000 -
RFQ
ECAD 7658 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00HHCG-P-A-DK00000 EAR99 8504.40.9540 1 520W 7 93% 5V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 8.3 A 3 A
CX10S-DCADGB-P-A-DK00000 Advanced Energy CX10S-DCADGB-P-A-DK00000 -
RFQ
ECAD 2914 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCADGB-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 24V 5V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 21 A 4.17 A 3 A 3 A
WM1-135797 Vicor Corporation WM1-135797 -
RFQ
ECAD 4457 0.00000000 Vicor Corporation * Bulk Obsolete - Not Applicable 1102-WM1-135797 OBSOLETE 1
NMP1K2-C#CEKH-00 MEAN WELL USA Inc. NMP1K2-C#CEKH-00 728.6700
RFQ
ECAD 2069 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1080W 5 88.5% 5V 5V 12V 48V 24V - - 4 kV 60601-1; 62368-1 36 A 36 A 20 A 5 A 10 A
CX10S-DB0HHA-P-A-DK00000 Advanced Energy CX10S-DB0HHA-P-A-DK00000 -
RFQ
ECAD 2684 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DB0HHA-P-A-DK00000 EAR99 8504.40.9540 1 685W 7 93% 48V 12V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 6 A 3 A 6 A 3 A
CX10S-GCDBGC-P-A-DK00000 Advanced Energy CX10S-GCDBGC-P-A-DK00000 -
RFQ
ECAD 1890 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCDBGC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 24V 24V 48V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 4.17 A 15 A 3 A
CX10S-GCBB0C-P-A-DK00000 Advanced Energy CX10S-GCBB0C-P-A-DK00000 -
RFQ
ECAD 1439 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCBB0C-P-A-DK00000 EAR99 8504.40.9540 1 680W 6 93% 24V 24V 24V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 15 A 15 A 8.3 A
CX10S-C0CCBA-P-A-DK00000 Advanced Energy CX10S-C0CCBA-P-A-DK00000 -
RFQ
ECAD 9719 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0CCBA-P-A-DK00000 EAR99 8504.40.9540 1 885W 5 93% 24V 24V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 8.3 A 15 A 21 A
IMP4-1E0-4NL-4NQ-00 Artesyn Embedded Power IMP4-1E0-4NL-4NQ-00 -
RFQ
ECAD 7445 0.00000000 Artesyn Embedded Power iMP® (1158W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP4-1E0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC - RoHS Compliant Not Applicable EAR99 8504.40.9540 1 511W 5 85% 5V 15V 12V 15V 24V 24V No 2 kV 35 A 8 A 4 A 8 A 2 A
MX8-7814759-2-EL Vicor Corporation MX8-7814759-2-EL -
RFQ
ECAD 5366 0.00000000 Vicor Corporation - Bulk Obsolete - Not Applicable 1102-MX8-7814759-2-EL OBSOLETE 1
CX10S-BCBHHD-P-A-DK00000 Advanced Energy CX10S-BCBHHD-P-A-DK00000 -
RFQ
ECAD 4732 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCBHHD-P-A-DK00000 EAR99 8504.40.9540 1 960W 8 93% 12V 24V 12V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 15 A 6 A 3 A 6 A
FL4-13-12087-MI Vicor Corporation FL4-13-12087-MI -
RFQ
ECAD 2917 0.00000000 Vicor Corporation * Bulk Obsolete - Not Applicable 1102-FL4-13-12087-MI OBSOLETE 1
CX10S-DDHCHC-P-A-DK00000 Advanced Energy CX10S-DDHCHC-P-A-DK00000 -
RFQ
ECAD 7758 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDHCHC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 48V 48V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 6 A 3 A 8.3 A 6 A
NMP1K2-EHHEC#-00 MEAN WELL USA Inc. NMP1K2-EHHEC#-00 728.6700
RFQ
ECAD 1507 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1140W 5 88.5% 12V 24V 24V 12V 5V - - 4 kV 60601-1; 62368-1 20 A 10 A 10 A 20 A 36 A
CX10S-BB0AAA-P-A-DK00000 Advanced Energy CX10S-BB0AAA-P-A-DK00000 -
RFQ
ECAD 4762 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BB0AAA-P-A-DK00000 EAR99 8504.40.9540 1 675W 5 93% 12V 12V 5V 5V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 21 A 21 A 21 A
NMP1K2-K#KCHK-00 MEAN WELL USA Inc. NMP1K2-K#KCHK-00 728.6700
RFQ
ECAD 4201 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1140W 5 88.5% 48V 48V 5V 24V 48V - - 4 kV 60601-1; 62368-1 5 A 5 A 36 A 10 A 5 A
CX10S-GCHCBB-P-A-DK00000 Advanced Energy CX10S-GCHCBB-P-A-DK00000 -
RFQ
ECAD 4161 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCHCBB-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 24V 24V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 6 A 3 A 8.3 A
CX10S-DHC0G0-P-A-DK00000 Advanced Energy CX10S-DHC0G0-P-A-DK00000 -
RFQ
ECAD 5930 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHC0G0-P-A-DK00000 EAR99 8504.40.9540 1 620W 6 93% 48V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 8.3 A 3 A 3 A
BSM550-480-BET-S00 Astrodyne TDI BSM550-480-BET-S00 215.0600
RFQ
ECAD 52 0.00000000 Astrodyne TDI BSM550 (550W) Box Active -20°C ~ 70°C (With Derating) Medical 7.00" L x 4.36" W x 1.58" H (177.8mm x 110.7mm x 40.1mm) Chassis Mount Enclosed Standby Output, Universal Input BSM550 CB, CE, cTUVus, TUV 80 ~ 275 VAC, 110 ~ 380 VDC download ROHS3 Compliant 1 (Unlimited) 2622-BSM550-480-BET-S00 EAR99 8504.40.9530 1 552W 1 92% 48V - - - - - No 4 kV 60601-1 11.5 A
CX10S-GHAAGC-P-A-DK00000 Advanced Energy CX10S-GHAAGC-P-A-DK00000 -
RFQ
ECAD 7949 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHAAGC-P-A-DK00000 EAR99 8504.40.9540 1 750W 9 93% 24V 24V 5V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 21 A 21 A
CX10S-HGC00D-P-A-DK00000 Advanced Energy CX10S-HGC00D-P-A-DK00000 -
RFQ
ECAD 7419 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGC00D-P-A-DK00000 EAR99 8504.40.9540 1 620W 6 93% 5V 24V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 8.3 A 4.17 A
CX10S-GAGAAH-P-A-DK00000 Advanced Energy CX10S-GAGAAH-P-A-DK00000 -
RFQ
ECAD 5018 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAGAAH-P-A-DK00000 EAR99 8504.40.9540 1 655W 9 93% 24V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 3 A 3 A 21 A