SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-BB0CGD-P-A-DK00000 Advanced Energy CX10S-BB0CGD-P-A-DK00000 -
RFQ
ECAD 4733 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BB0CGD-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 12V 12V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 8.3 A 3 A 3 A 4.17 A
VI-MUL-CQ Vicor Corporation VI-MUL-CQ 1.0000
RFQ
ECAD 8072 0.00000000 Vicor Corporation * Bulk Active VI-MUL - RoHS non-compliant 1 (Unlimited) REACH Affected EAR99 8504.40.9530 1
CX10S-BD0DCB-P-A-DK00000 Advanced Energy CX10S-BD0DCB-P-A-DK00000 -
RFQ
ECAD 9407 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BD0DCB-P-A-DK00000 EAR99 8504.40.9540 1 960W 5 93% 12V 48V 48V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 4.17 A 8.3 A 15 A
MP8-3L2-03 Artesyn Embedded Power MP8-3L2-03 -
RFQ
ECAD 9949 0.00000000 Artesyn Embedded Power MP8 (1000W) Bulk Obsolete -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 7.00" W x 2.50" H (254.0mm x 177.8mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, PFC, Remote On/Off, Universal Input CB, CE, CSA, UL, VDE 85 ~ 264 VAC, 120 ~ 300 VDC download Not Applicable EAR99 8504.40.9580 1 1000W 2 85% - 24V - - - - - 15 A
VI-NF3-IS Vicor Corporation VI-NF3-IS -
RFQ
ECAD 9262 0.00000000 Vicor Corporation * Bulk Obsolete VI-NF3 - 1 (Unlimited) REACH Affected EAR99 8504.40.9530 1
LPS41 Artesyn Embedded Power LPS41 44.5975
RFQ
ECAD 3984 0.00000000 Artesyn Embedded Power LPS40 (40W) Bulk Last Time Buy 0°C ~ 70°C (With Derating) ITE (Commercial) 5.00" L x 3.00" W x 1.14" H (127.0mm x 76.2mm x 29.0mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Remote Sense, Universal Input CB, CE 85 ~ 264 VAC download RoHS Compliant 1 (Unlimited) EAR99 8504.40.6018 80 40W (55W Forced Air) 1 70% 3.3V - - - - No 8 A
1010563CHCO Integrated Power Designs 1010563CHCO 257.8000
RFQ
ECAD 50 0.00000000 Integrated Power Designs REL-185 (185W) Box Active 0°C ~ 70°C (With Derating) Industrial, ITE (Commercial), Laboratory, Medical 6.25" L x 3.96" W x 1.48" H (156.8mm x 100.5mm x 37.6mm) Chassis Mount Enclosed Adjustable Output, Remote Sense, Universal Input 1010563 CE, cURus, TUV, UKCA 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 185W 4 82% 5V -5V 12V -12V - - 60601-1; 62368-1 20 A 10 A 2 A 2 A
NMP1K2-H#CCCE-03 MEAN WELL USA Inc. NMP1K2-H#CCCE-03 698.9800
RFQ
ECAD 5070 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1020W 4 88.5% 24V 5V 5V 12V - - 4 kV 60601-1; 62368-1 10 A 72 A 36 A 20 A
CX10S-CCGDAA-P-A-DK00000 Advanced Energy CX10S-CCGDAA-P-A-DK00000 -
RFQ
ECAD 7522 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CCGDAA-P-A-DK00000 EAR99 8504.40.9540 1 930W 7 93% 24V 24V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 3 A 3 A 4.17 A 21 A
CX10S-AHHAAB-P-A-DK00000 Advanced Energy CX10S-AHHAAB-P-A-DK00000 -
RFQ
ECAD 6015 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AHHAAB-P-A-DK00000 EAR99 8504.40.9540 1 695W 8 93% 5V 5V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 6 A 3 A 21 A
CX10S-ABH0DB-P-A-DK00000 Advanced Energy CX10S-ABH0DB-P-A-DK00000 -
RFQ
ECAD 5368 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABH0DB-P-A-DK00000 EAR99 8504.40.9540 1 765W 6 93% 5V 12V 5V 24V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 6 A 3 A 4.17 A 15 A
CX10S-HHHD0G-P-A-DK00000 Advanced Energy CX10S-HHHD0G-P-A-DK00000 -
RFQ
ECAD 5692 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHHD0G-P-A-DK00000 EAR99 8504.40.9540 1 620W 9 93% 5V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 6 A 3 A
NMP1K2-CHHKCH-00 MEAN WELL USA Inc. NMP1K2-CHHKCH-00 816.1200
RFQ
ECAD 6352 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 6 88.5% 5V 24V 24V 48V 5V 24V - 4 kV 60601-1; 62368-1 36 A 10 A 10 A 5 A 36 A 10 A
CX10S-B0GBGG-P-A-DK00000 Advanced Energy CX10S-B0GBGG-P-A-DK00000 -
RFQ
ECAD 3155 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-B0GBGG-P-A-DK00000 EAR99 8504.40.9540 1 720W 8 93% 12V 24V 24V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 15 A 3 A 3 A
CX10S-0CDDAA-P-A-DK00000 Advanced Energy CX10S-0CDDAA-P-A-DK00000 -
RFQ
ECAD 1482 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0CDDAA-P-A-DK00000 EAR99 8504.40.9540 1 810W 5 93% 24V 48V 48V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 4.17 A 21 A 21 A
NEVO+600SL-2200-DK000 Vox Power Ltd. NEVO+600SL-2200-DK000 368.0387
RFQ
ECAD 6854 0.00000000 Vox Power Ltd. NEVO+600SL Box Active -20°C ~ 70°C ITE (Commercial) 3.06" L x 3.06" W x 1.61" H (77.7mm x 77.7mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input NEVO+600 CB, CE, CSA, IEC, UL 85 ~ 264 VAC, 120 ~ 370 VDC download Not Applicable REACH Unaffected 2050-NEVO+600SL-2200-DK000 EAR99 8504.40.9530 1 300W 2 86% 12V 12V - - - - No 4 kV 60950-1; 62368-1 15 A 15 A
CX10S-ACGBA0-P-A-DK00000 Advanced Energy CX10S-ACGBA0-P-A-DK00000 -
RFQ
ECAD 7580 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACGBA0-P-A-DK00000 EAR99 8504.40.9540 1 710W 6 93% 5V 24V 24V 24V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 3 A 3 A 15 A 21 A
CX10S-ADCAA0-P-A-DK00000 Advanced Energy CX10S-ADCAA0-P-A-DK00000 -
RFQ
ECAD 9117 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADCAA0-P-A-DK00000 EAR99 8504.40.9540 1 715W 5 93% 5V 48V 24V 5V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 8.3 A 21 A 21 A
CX10S-HGDABA-P-A-DK00000 Advanced Energy CX10S-HGDABA-P-A-DK00000 -
RFQ
ECAD 8584 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGDABA-P-A-DK00000 EAR99 8504.40.9540 1 810W 8 93% 5V 24V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 4.17 A 21 A
CX10S-GGB0CA-P-A-DK00000 Advanced Energy CX10S-GGB0CA-P-A-DK00000 -
RFQ
ECAD 6581 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGB0CA-P-A-DK00000 EAR99 8504.40.9540 1 725W 7 93% 24V 24V 24V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 15 A 8.3 A
CX10S-DGAGCC-P-A-DK00000 Advanced Energy CX10S-DGAGCC-P-A-DK00000 -
RFQ
ECAD 5691 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGAGCC-P-A-DK00000 EAR99 8504.40.9540 1 945W 8 93% 48V 24V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 21 A 3 A 3 A
CX10S-C0HCBA-P-A-DK00000 Advanced Energy CX10S-C0HCBA-P-A-DK00000 -
RFQ
ECAD 8216 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0HCBA-P-A-DK00000 EAR99 8504.40.9540 1 785W 6 93% 24V 5V 24V 24V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 8.3 A 15 A 21 A
CX10S-BC0H0G-P-A-DK00000 Advanced Energy CX10S-BC0H0G-P-A-DK00000 -
RFQ
ECAD 8805 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BC0H0G-P-A-DK00000 EAR99 8504.40.9540 1 600W 6 93% 12V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 6 A 3 A 3 A 3 A
LCW50US48 XP Power LCW50US48 15.7800
RFQ
ECAD 6 0.00000000 XP Power LCW50 (50W) Box Active -30°C ~ 70°C (With Derating) Household Appliances, ITE (Commercial), Industrial 3.90" L x 3.23" W x 1.18" H (99.0mm x 82.0mm x 30.0mm) Chassis Mount Enclosed Adjustable Output, DC Input Capable CE, EN, UKCA, UL 85 ~ 305 VAC, 120 ~ 430 VDC download ROHS3 Compliant Not Applicable 1470-LCW50US48 EAR99 8504.40.9520 1 53W 1 90% 48V - - - - - No 4 kV 60335-1; 62368-1 1.1 A
CX10S-CAB0GD-P-A-DK00000 Advanced Energy CX10S-CAB0GD-P-A-DK00000 -
RFQ
ECAD 4153 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CAB0GD-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 24V 5V 12V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 15 A 3 A 3 A 4.17 A
CX10S-0GBBDG-P-A-DK00000 Advanced Energy CX10S-0GBBDG-P-A-DK00000 -
RFQ
ECAD 8046 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GBBDG-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 24V 24V 12V 12V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 15 A 4.17 A 3 A
NMP1K2-KK#KHH-05 MEAN WELL USA Inc. NMP1K2-KK#KHH-05 698.9800
RFQ
ECAD 9588 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 4 88.5% 48V 48V 48V 24V - - 4 kV 60601-1; 62368-1 5 A 5 A 5 A 20 A
FLS250-2048 Bel Power Solutions FLS250-2048 235.0500
RFQ
ECAD 24 0.00000000 Bel Power Solutions FLS250 (250W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial) 4.50" L x 2.50" W x 1.58" H (114.3mm x 63.5mm x 40.1mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, PFC, Remote On/Off, Standby Output, Universal Input CB, CE, CSA, NEMKO, UL 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 179-FLS250-2048 EAR99 8504.40.9530 24 250W (346W Forced Air) 1 94% 48V - - - - - - 4 kV 62368-1 7.2 A
CX10S-BHABH0-P-A-DK00000 Advanced Energy CX10S-BHABH0-P-A-DK00000 -
RFQ
ECAD 8931 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BHABH0-P-A-DK00000 EAR99 8504.40.9540 1 665W 7 93% 12V 5V 24V 5V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 21 A 15 A 6 A
NMP1K2-#EEKKE-00 MEAN WELL USA Inc. NMP1K2-#EEKKE-00 728.6700
RFQ
ECAD 1824 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 12V 12V 48V 48V 12V - - 4 kV 60601-1; 62368-1 20 A 20 A 5 A 5 A 20 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse