SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-D0HBAB-P-A-DK00000 Advanced Energy CX10S-D0HBAB-P-A-DK00000 -
RFQ
ECAD 2097 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0HBAB-P-A-DK00000 EAR99 8504.40.9540 1 765W 6 93% 48V 5V 24V 12V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 15 A 21 A 15 A
NMP1K2-EC#CC#-00 MEAN WELL USA Inc. NMP1K2-EC#CC#-00 641.2200
RFQ
ECAD 2814 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 780W 4 88.5% 12V 5V 5V 5V - - 4 kV 60601-1; 62368-1 20 A 36 A 36 A 36 A
CX10S-00CAH0-P-A-DK00000 Advanced Energy CX10S-00CAH0-P-A-DK00000 -
RFQ
ECAD 9264 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00CAH0-P-A-DK00000 EAR99 8504.40.9540 1 405W 4 93% 24V 5V 5V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 6 A 3 A
CX10S-ADG0AG-P-A-DK00000 Advanced Energy CX10S-ADG0AG-P-A-DK00000 -
RFQ
ECAD 1382 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADG0AG-P-A-DK00000 EAR99 8504.40.9540 1 650W 7 93% 5V 48V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 3 A 3 A 21 A 3 A
CX10S-CCDCHH-P-A-DK00000 Advanced Energy CX10S-CCDCHH-P-A-DK00000 -
RFQ
ECAD 4803 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CCDCHH-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 24V 48V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 4.17 A 8.3 A 6 A 3 A
CX10S-HDCADD-P-A-DK00000 Advanced Energy CX10S-HDCADD-P-A-DK00000 -
RFQ
ECAD 5126 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDCADD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 5V 24V 48V 24V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 8.3 A 21 A 4.17 A
NEVO+600M-3854-DK000 Vox Power Ltd. NEVO+600M-3854-DK000 441.6493
RFQ
ECAD 6420 0.00000000 Vox Power Ltd. NEVO+600M Box Active -20°C ~ 70°C Medical 5.27" L x 3.06" W x 1.61" H (133.8mm x 77.7mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input NEVO+600 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download Not Applicable REACH Unaffected 2050-NEVO+600M-3854-DK000 EAR99 8504.40.9540 1 450W 5 86% 24V 24V 24V 12V 12V 48V No 4 kV 60601-1 7.5 A 3.125 A 3.125 A 5 A 5 A 3.75 A
CX10S-AGGAHB-P-A-DK00000 Advanced Energy CX10S-AGGAHB-P-A-DK00000 -
RFQ
ECAD 5128 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGGAHB-P-A-DK00000 EAR99 8504.40.9540 1 730W 9 93% 5V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 3 A 3 A 21 A
CX10S-0HCBBG-P-A-DK00000 Advanced Energy CX10S-0HCBBG-P-A-DK00000 -
RFQ
ECAD 7614 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HCBBG-P-A-DK00000 EAR99 8504.40.9540 1 780W 7 93% 5V 24V 24V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 8.3 A 15 A 15 A 3 A
TXR3026 TDK-Lambda Americas Inc TXR3026 -
RFQ
ECAD 8516 0.00000000 TDK-Lambda Americas Inc - Bulk Obsolete -40°C ~ 65°C ITE (Commercial) 20.70" L x 16.00" W x 3.49" H (526.00mm x 406.00mm x 88.6mm) Rack Mount Front End Adjustable Output, Hot Swappable, Remote On/Off CE 180 ~ 264 VAC - Not Applicable EAR99 8504.40.9540 1 - 1 - - - - - - - -
CX10S-DDHA0G-P-A-DK00000 Advanced Energy CX10S-DDHA0G-P-A-DK00000 -
RFQ
ECAD 4499 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDHA0G-P-A-DK00000 EAR99 8504.40.9540 1 725W 7 93% 48V 48V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 6 A 3 A 21 A 3 A
CX10S-ABHHDC-P-A-DK00000 Advanced Energy CX10S-ABHHDC-P-A-DK00000 -
RFQ
ECAD 1723 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABHHDC-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 5V 12V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 6 A 3 A 6 A 3 A
CX10S-GDDHCA-P-A-DK00000 Advanced Energy CX10S-GDDHCA-P-A-DK00000 -
RFQ
ECAD 1790 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDDHCA-P-A-DK00000 EAR99 8504.40.9540 1 925W 8 93% 24V 24V 48V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 4.17 A 6 A 3 A
NMP1K2-EK#EEK-00 MEAN WELL USA Inc. NMP1K2-EK#EEK-00 728.6700
RFQ
ECAD 4661 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 12V 48V 12V 12V 48V - - 4 kV 60601-1; 62368-1 20 A 5 A 20 A 20 A 5 A
CX10S-BAC0DG-P-A-DK00000 Advanced Energy CX10S-BAC0DG-P-A-DK00000 -
RFQ
ECAD 2260 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BAC0DG-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 12V 5V 24V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 8.3 A 4.17 A 3 A 3 A
CX10S-A00HCA-P-A-DK00000 Advanced Energy CX10S-A00HCA-P-A-DK00000 -
RFQ
ECAD 1162 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A00HCA-P-A-DK00000 EAR99 8504.40.9540 1 510W 5 93% 5V 5V 24V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 8.3 A 21 A
VI-RU002-EYYV Vicor Corporation VI-RU002-EYYV -
RFQ
ECAD 3680 0.00000000 Vicor Corporation * Bulk Obsolete VI-RU002 - 1 (Unlimited) REACH Affected EAR99 8504.40.9510 1
WM5-15635 Vicor Corporation WM5-15635 -
RFQ
ECAD 7586 0.00000000 Vicor Corporation * Bulk Obsolete - Not Applicable 1102-WM5-15635 OBSOLETE 1
NMP1K2-ECHHHK-00 MEAN WELL USA Inc. NMP1K2-ECHHHK-00 816.1200
RFQ
ECAD 2431 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 6 88.5% 12V 5V 24V 24V 24V 48V - 4 kV 60601-1; 62368-1 20 A 36 A 10 A 10 A 10 A 5 A
CX10S-GGCHHH-P-A-DK00000 Advanced Energy CX10S-GGCHHH-P-A-DK00000 -
RFQ
ECAD 6438 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGCHHH-P-A-DK00000 EAR99 8504.40.9540 1 740W 11 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 8.3 A 6 A
ZWS100BAF-24 TDK-Lambda Americas Inc ZWS100BAF-24 102.7100
RFQ
ECAD 1512 0.00000000 TDK-Lambda Americas Inc ZWS100BAF (100W) Bulk Active -10°C ~ 70°C (With Derating) ITE (Commercial) 6.10" L x 2.44" W x 1.30" H (155.0mm x 62.0mm x 33.0mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Load Sharing, PFC, Universal Input ZWS100 CE 85 ~ 265 VAC download RoHS Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 1 100W 1 87% 24V - - - - - 3 kV 4.3 A
IMP4-1E0-1N0-1Q0-00 Artesyn Embedded Power IMP4-1E0-1N0-1Q0-00 -
RFQ
ECAD 6260 0.00000000 Artesyn Embedded Power iMP® (1158W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP4-1E0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC - RoHS Compliant Not Applicable EAR99 8504.40.9540 1 589W 3 85% 5V 15V 24V - - - No 2 kV 35 A 14 A 8.5 A
CX10S-HBDHHG-P-A-DK00000 Advanced Energy CX10S-HBDHHG-P-A-DK00000 -
RFQ
ECAD 9469 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBDHHG-P-A-DK00000 EAR99 8504.40.9540 1 800W 10 93% 5V 24V 12V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 4.17 A 6 A 3 A
CX10S-AAHDBH-P-A-DK00000 Advanced Energy CX10S-AAHDBH-P-A-DK00000 -
RFQ
ECAD 7827 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAHDBH-P-A-DK00000 EAR99 8504.40.9540 1 790W 8 93% 5V 5V 5V 24V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 6 A 3 A 4.17 A 15 A
CX10S-DHGH0G-P-A-DK00000 Advanced Energy CX10S-DHGH0G-P-A-DK00000 -
RFQ
ECAD 3142 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHGH0G-P-A-DK00000 EAR99 8504.40.9540 1 640W 9 93% 48V 5V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 3 A 3 A 6 A
CX10S-BCHGDA-P-A-DK00000 Advanced Energy CX10S-BCHGDA-P-A-DK00000 -
RFQ
ECAD 6299 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCHGDA-P-A-DK00000 EAR99 8504.40.9540 1 905W 8 93% 12V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 6 A 3 A 3 A 3 A
CX10S-CAHGBG-P-A-DK00000 Advanced Energy CX10S-CAHGBG-P-A-DK00000 -
RFQ
ECAD 7815 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CAHGBG-P-A-DK00000 EAR99 8504.40.9540 1 825W 9 93% 24V 5V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 6 A 3 A 3 A 3 A
CX10S-GBDGB0-P-A-DK00000 Advanced Energy CX10S-GBDGB0-P-A-DK00000 -
RFQ
ECAD 9929 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBDGB0-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 24V 24V 12V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 4.17 A 3 A 3 A
CX10S-GAABHD-P-A-DK00000 Advanced Energy CX10S-GAABHD-P-A-DK00000 -
RFQ
ECAD 2447 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAABHD-P-A-DK00000 EAR99 8504.40.9540 1 810W 8 93% 24V 24V 5V 5V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 21 A 15 A 6 A
CX10S-AACCGA-P-A-DK00000 Advanced Energy CX10S-AACCGA-P-A-DK00000 -
RFQ
ECAD 1775 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AACCGA-P-A-DK00000 EAR99 8504.40.9540 1 835W 7 93% 5V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 8.3 A 8.3 A 3 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse