SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-0BAGC0-P-A-DK00000 Advanced Energy CX10S-0BAGC0-P-A-DK00000 -
RFQ
ECAD 8223 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BAGC0-P-A-DK00000 EAR99 8504.40.9540 1 605W 5 93% 12V 5V 24V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 3 A 3 A 8.3 A
CX10S-CDA0HD-P-A-DK00000 Advanced Energy CX10S-CDA0HD-P-A-DK00000 -
RFQ
ECAD 8307 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDA0HD-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 24V 48V 5V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 21 A 6 A 3 A 4.17 A
NMP1K2-HKEEKE-00 MEAN WELL USA Inc. NMP1K2-HKEEKE-00 816.1200
RFQ
ECAD 4702 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 6 88.5% 24V 48V 12V 12V 48V 12V - 4 kV 60601-1; 62368-1 10 A 5 A 20 A 20 A 5 A 20 A
CX10S-HDADAH-P-A-DK00000 Advanced Energy CX10S-HDADAH-P-A-DK00000 -
RFQ
ECAD 4740 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDADAH-P-A-DK00000 EAR99 8504.40.9540 1 810W 8 93% 5V 24V 48V 5V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 21 A 4.17 A 21 A
CX10S-CDBCDA-P-A-DK00000 Advanced Energy CX10S-CDBCDA-P-A-DK00000 -
RFQ
ECAD 6250 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDBCDA-P-A-DK00000 EAR99 8504.40.9540 1 1000W 6 93% 24V 48V 12V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 15 A 8.3 A 4.17 A 21 A
MS1024 TDK-Lambda Americas Inc MS1024 -
RFQ
ECAD 3118 0.00000000 TDK-Lambda Americas Inc MS Bulk Obsolete -10°C ~ 71°C (With Derating) ITE (Commercial) 7.09" L x 3.82" W x 1.69" H (180.0mm x 97.0mm x 43.0mm) Chassis Mount Enclosed Adjustable Output, DC Input Capable, Remote On/Off, Universal Input CSA, UR 85 ~ 132 VAC download Not Applicable EAR99 8504.40.9580 1 72W 1 70% 24V - - - - - 2 kV 3 A
CX10S-CDCDH0-P-A-DK00000 Advanced Energy CX10S-CDCDH0-P-A-DK00000 -
RFQ
ECAD 4285 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDCDH0-P-A-DK00000 EAR99 8504.40.9540 1 900W 6 93% 24V 48V 24V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 8.3 A 4.17 A 6 A 3 A
CX10S-0AGAAG-P-A-DK00000 Advanced Energy CX10S-0AGAAG-P-A-DK00000 -
RFQ
ECAD 4359 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0AGAAG-P-A-DK00000 EAR99 8504.40.9540 1 555W 7 93% 5V 24V 24V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 21 A 21 A 3 A
CX10S-BCCHDD-P-A-DK00000 Advanced Energy CX10S-BCCHDD-P-A-DK00000 -
RFQ
ECAD 4564 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCCHDD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 12V 24V 24V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 8.3 A 6 A 3 A 4.17 A
IMP4-2L0-1Q0-4EE-00-A Artesyn Embedded Power IMP4-2L0-1Q0-4EE-00-A -
RFQ
ECAD 8824 0.00000000 Artesyn Embedded Power iMP® (1158W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP4-2L0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download RoHS Compliant Not Applicable EAR99 8504.40.9540 1 664W 4 85% 12V 24V 5V 5V - - No 2 kV 30 A 8.5 A 10 A 10 A
CX10S-0GGG00-P-A-DK00000 Advanced Energy CX10S-0GGG00-P-A-DK00000 -
RFQ
ECAD 5882 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GGG00-P-A-DK00000 EAR99 8504.40.9540 1 360W 6 93% 24V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 3 A 3 A
CX10S-HCCAGH-P-A-DK00000 Advanced Energy CX10S-HCCAGH-P-A-DK00000 -
RFQ
ECAD 5580 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HCCAGH-P-A-DK00000 EAR99 8504.40.9540 1 825W 9 93% 5V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 8.3 A 8.3 A 21 A 3 A
CX10S-CBGDGG-P-A-DK00000 Advanced Energy CX10S-CBGDGG-P-A-DK00000 -
RFQ
ECAD 8401 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBGDGG-P-A-DK00000 EAR99 8504.40.9540 1 940W 9 93% 24V 12V 24V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 3 A 3 A 4.17 A 3 A
CX10S-AA0ADC-P-A-DK00000 Advanced Energy CX10S-AA0ADC-P-A-DK00000 -
RFQ
ECAD 3505 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AA0ADC-P-A-DK00000 EAR99 8504.40.9540 1 715W 5 93% 5V 5V 5V 48V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 21 A 4.17 A 8.3 A
CX10S-GDHHA0-P-A-DK00000 Advanced Energy CX10S-GDHHA0-P-A-DK00000 -
RFQ
ECAD 3771 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDHHA0-P-A-DK00000 EAR99 8504.40.9540 1 625W 8 93% 24V 24V 48V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 6 A 3 A 6 A
VP-D2098219 Vicor Corporation VP-D2098219 -
RFQ
ECAD 7515 0.00000000 Vicor Corporation * Bulk Obsolete VP-D - 1 (Unlimited) OBSOLETE 1
NMP1K2-#K#HK#-00 MEAN WELL USA Inc. NMP1K2-#K#HK#-00 553.7800
RFQ
ECAD 3251 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 720W 3 88.5% 48V 24V 48V - - - 4 kV 60601-1; 62368-1 5 A 10 A 5 A
CX10S-D0BGDH-P-A-DK00000 Advanced Energy CX10S-D0BGDH-P-A-DK00000 -
RFQ
ECAD 5894 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0BGDH-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 48V 12V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 3 A 3 A 4.17 A 6 A
CUS150M-48 TDK-Lambda Americas Inc CUS150M-48 76.7700
RFQ
ECAD 2832 0.00000000 TDK-Lambda Americas Inc CUS150M (150W) Box Active -20°C ~ 85°C (With Derating) ITE (Commercial), Medical 4.00" L x 2.00" W x 1.24" H (101.6mm x 50.8mm x 31.5mm) Chassis Mount Open Frame Standby Output, Universal Input CUS150 - 85 ~ 264 VAC download RoHS Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 1 120W (150W Forced Air) 1 94% 48V - - - - - 3.12 A
CX10S-GGGHCH-P-A-DK00000 Advanced Energy CX10S-GGGHCH-P-A-DK00000 -
RFQ
ECAD 1776 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGGHCH-P-A-DK00000 EAR99 8504.40.9540 1 760W 11 93% 24V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 3 A 3 A
CX10S-CGDGG0-P-A-DK00000 Advanced Energy CX10S-CGDGG0-P-A-DK00000 -
RFQ
ECAD 5542 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGDGG0-P-A-DK00000 EAR99 8504.40.9540 1 760W 8 93% 24V 24V 24V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 4.17 A 3 A 3 A
HB28-1-A+G SL Power Electronics Manufacture of Condor/Ault Brands HB28-1-A+G 87.0700
RFQ
ECAD 141 0.00000000 SL Power Electronics Manufacture of Condor/Ault Brands Linear B Bulk Active 0°C ~ 70°C (With Derating) ITE (Commercial) 4.88" L x 4.00" W x 1.80" H (124.0mm x 101.6mm x 45.7mm) Chassis Mount Linear Adjustable Output, Remote Sense, Universal Input HB28-1 CE, cURus, TUV 100 ~ 240 VAC download RoHS Compliant Not Applicable EAR99 8504.40.6018 20 28W 1 - 28V - - - - - 1 A
NMP1K2-KHKKCE-03 MEAN WELL USA Inc. NMP1K2-KHKKCE-03 782.3100
RFQ
ECAD 3182 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 48V 24V 48V 48V 5V 12V - 4 kV 60601-1; 62368-1 5 A 10 A 5 A 5 A 36 A 20 A
CX10S-AC0AAD-P-A-DK00000 Advanced Energy CX10S-AC0AAD-P-A-DK00000 -
RFQ
ECAD 3495 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AC0AAD-P-A-DK00000 EAR99 8504.40.9540 1 515W 5 93% 5V 24V 5V 5V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 21 A 21 A 4.17 A
CX10S-ACAHAA-P-A-DK00000 Advanced Energy CX10S-ACAHAA-P-A-DK00000 -
RFQ
ECAD 9101 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACAHAA-P-A-DK00000 EAR99 8504.40.9540 1 720W 7 93% 5V 24V 5V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 21 A 6 A 3 A 21 A
CX10S-AACCGC-P-A-DK00000 Advanced Energy CX10S-AACCGC-P-A-DK00000 -
RFQ
ECAD 1200 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AACCGC-P-A-DK00000 EAR99 8504.40.9540 1 930W 7 93% 5V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 8.3 A 8.3 A 3 A 3 A
AMES350-48SNZ aimtec AMES350-48SNZ 55.1300
RFQ
ECAD 10 0.00000000 aimtec AMES350-NZ Box Active -30°C ~ 70°C (With Derating) Household Appliances, ITE (Commercial) 8.46" L x 4.53" W x 1.18" H (215.0mm x 115.0mm x 30.0mm) Chassis Mount Enclosed Adjustable Output AMES350 CB, CE, EN, IEC, UL 90 ~ 264 VAC, 240 ~ 373 VDC download ROHS3 Compliant 1 (Unlimited) REACH info available upon request 2721-AMES350-48SNZ EAR99 8504.40.9582 1 350W 1 88.5% 48V - - - - - - 3 kV 60335-1; 62368-1 7.3 A
LDA50F-12-C Cosel USA, Inc. LDA50F-12-C -
RFQ
ECAD 7062 0.00000000 Cosel USA, Inc. LDA (50W) Box Obsolete -10°C ~ 60°C (With Derating) ITE (Commercial) 7.68" L x 2.17" W x 1.02" H (195.0mm x 55.0mm x 26.0mm) Chassis Mount Open Frame Adjustable Output, Universal Input LDA50F cCSAus, CE, cURus, TUV 85 ~ 264 VAC, 110 ~ 370 VDC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9510 1 52W 1 80% 12V - - - - - - 60950-1 4.3 A
NMP1K2-K#CCCK-03 MEAN WELL USA Inc. NMP1K2-K#CCCK-03 733.5900
RFQ
ECAD 2488 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1020W 4 88.5% 48V 5V 5V 48V - - 4 kV 60601-1; 62368-1 5 A 72 A 36 A 5 A
CX10S-DBHHCD-P-A-DK00000 Advanced Energy CX10S-DBHHCD-P-A-DK00000 -
RFQ
ECAD 2597 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBHHCD-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 48V 12V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 6 A 3 A 6 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse