SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-AG0GBH-P-A-DK00000 Advanced Energy CX10S-AG0GBH-P-A-DK00000 -
RFQ
ECAD 6889 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AG0GBH-P-A-DK00000 EAR99 8504.40.9540 1 625W 8 93% 5V 24V 24V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 3 A 3 A 15 A
SMP350PS48 XP Power SMP350PS48 127.9700
RFQ
ECAD 3504 0.00000000 XP Power SMP350 (350W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.00" L x 3.60" W x 1.70" H (177.8mm x 91.4mm x 43.2mm) Chassis Mount Enclosed Remote On/Off SMP350 CB, CE, TUV, UL 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) 1470-4451 EAR99 8504.40.6018 1 350W 1 93% 48V - - - - No 4 kV 62368-1 7.3 A
CX10S-CDHCDH-P-A-DK00000 Advanced Energy CX10S-CDHCDH-P-A-DK00000 -
RFQ
ECAD 4417 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDHCDH-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 48V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 6 A 3 A 8.3 A 4.17 A
CX10S-A0DDGG-P-A-DK00000 Advanced Energy CX10S-A0DDGG-P-A-DK00000 -
RFQ
ECAD 7385 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0DDGG-P-A-DK00000 EAR99 8504.40.9540 1 745W 7 93% 5V 48V 48V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 4.17 A 3 A 3 A 3 A
CX10S-CAADAB-P-A-DK00000 Advanced Energy CX10S-CAADAB-P-A-DK00000 -
RFQ
ECAD 9461 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CAADAB-P-A-DK00000 EAR99 8504.40.9540 1 895W 6 93% 24V 5V 5V 48V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 21 A 4.17 A 21 A 15 A
WP8-78584 Vicor Corporation WP8-78584 -
RFQ
ECAD 1887 0.00000000 Vicor Corporation - Bulk Obsolete - Not Applicable 1102-WP8-78584 OBSOLETE 1
CX10S-GCCHDD-P-A-DK00000 Advanced Energy CX10S-GCCHDD-P-A-DK00000 -
RFQ
ECAD 6383 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCCHDD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 8.3 A 6 A 3 A
CX10S-D0GDCB-P-A-DK00000 Advanced Energy CX10S-D0GDCB-P-A-DK00000 -
RFQ
ECAD 9742 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0GDCB-P-A-DK00000 EAR99 8504.40.9540 1 900W 6 93% 48V 24V 24V 48V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 4.17 A 8.3 A 15 A
CX10S-0BDH0B-P-A-DK00000 Advanced Energy CX10S-0BDH0B-P-A-DK00000 -
RFQ
ECAD 8472 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BDH0B-P-A-DK00000 EAR99 8504.40.9540 1 660W 5 93% 12V 48V 5V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 6 A 3 A 15 A
CX10S-0ADBHA-P-A-DK00000 Advanced Energy CX10S-0ADBHA-P-A-DK00000 -
RFQ
ECAD 2285 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0ADBHA-P-A-DK00000 EAR99 8504.40.9540 1 670W 6 93% 5V 48V 12V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 15 A 6 A 3 A 21 A
CX10S-G0ADCG-P-A-DK00000 Advanced Energy CX10S-G0ADCG-P-A-DK00000 -
RFQ
ECAD 7077 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0ADCG-P-A-DK00000 EAR99 8504.40.9540 1 745W 7 93% 24V 24V 5V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 4.17 A 8.3 A 3 A
CX10S-AGDGBB-P-A-DK00000 Advanced Energy CX10S-AGDGBB-P-A-DK00000 -
RFQ
ECAD 2660 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGDGBB-P-A-DK00000 EAR99 8504.40.9540 1 905W 8 93% 5V 24V 24V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 4.17 A 3 A 3 A
CX10S-DBBDDD-P-A-DK00000 Advanced Energy CX10S-DBBDDD-P-A-DK00000 -
RFQ
ECAD 5279 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBBDDD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 6 93% 48V 12V 12V 48V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 15 A 4.17 A 4.17 A 4.17 A
1011010CH Integrated Power Designs 1011010CH 348.1600
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-325 (350W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 6.20" L x 4.00" W x 1.75" H (157.5mm x 101.6mm x 44.5mm) Chassis Mount Chassis Adjustable Output, Remote Sense, Universal Input 1011010 CE, cURus, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 325W 1 85% 2.5V - - - - - - 60601-1; 62368-1 65 A
NMP1K2-CHEECK-03 MEAN WELL USA Inc. NMP1K2-CHEECK-03 821.0300
RFQ
ECAD 7212 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 5V 24V 12V 12V 5V 48V - 4 kV 60601-1; 62368-1 36 A 10 A 20 A 20 A 36 A 5 A
CX10S-AAA0AG-P-A-DK00000 Advanced Energy CX10S-AAA0AG-P-A-DK00000 -
RFQ
ECAD 8376 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAA0AG-P-A-DK00000 EAR99 8504.40.9540 1 540W 6 93% 5V 5V 5V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 21 A 21 A 3 A 3 A
VI-RU022-CVUU Vicor Corporation VI-RU022-CVUU -
RFQ
ECAD 3333 0.00000000 Vicor Corporation * Bulk Obsolete VI-RU022 - 1 (Unlimited) REACH Affected OBSOLETE 1
CX10S-HCA00D-P-A-DK00000 Advanced Energy CX10S-HCA00D-P-A-DK00000 -
RFQ
ECAD 9551 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HCA00D-P-A-DK00000 EAR99 8504.40.9540 1 605W 5 93% 5V 24V 24V 5V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 8.3 A 21 A 4.17 A
CX10S-00H0BH-P-A-DK00000 Advanced Energy CX10S-00H0BH-P-A-DK00000 -
RFQ
ECAD 6702 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00H0BH-P-A-DK00000 EAR99 8504.40.9540 1 380W 5 93% 5V 24V 12V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 6 A 3 A
CX10S-HHACDB-P-A-DK00000 Advanced Energy CX10S-HHACDB-P-A-DK00000 -
RFQ
ECAD 6095 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHACDB-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 5V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 21 A 8.3 A
CX10S-CHGCGH-P-A-DK00000 Advanced Energy CX10S-CHGCGH-P-A-DK00000 -
RFQ
ECAD 4488 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHGCGH-P-A-DK00000 EAR99 8504.40.9540 1 840W 10 93% 24V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 3 A 3 A 8.3 A
NMP1K2-KEKKHH-00 MEAN WELL USA Inc. NMP1K2-KEKKHH-00 816.1200
RFQ
ECAD 2793 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 6 88.5% 48V 12V 48V 48V 24V 24V - 4 kV 60601-1; 62368-1 5 A 20 A 5 A 5 A 10 A 10 A
NEVO+600M-0415-DK000 Vox Power Ltd. NEVO+600M-0415-DK000 420.2820
RFQ
ECAD 4820 0.00000000 Vox Power Ltd. NEVO+600M Box Active -20°C ~ 70°C Medical 5.27" L x 3.06" W x 1.61" H (133.8mm x 77.7mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input NEVO+600 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download Not Applicable REACH Unaffected 2050-NEVO+600M-0415-DK000 EAR99 8504.40.9530 1 425W 4 86% 48V 5V 12V 12V - - No 4 kV 60601-1 3.75 A 25 A 5 A 5 A
CX10S-DGCDA0-P-A-DK00000 Advanced Energy CX10S-DGCDA0-P-A-DK00000 -
RFQ
ECAD 9142 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGCDA0-P-A-DK00000 EAR99 8504.40.9540 1 825W 6 93% 48V 24V 24V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 8.3 A 4.17 A 21 A
CX10S-DCDBA0-P-A-DK00000 Advanced Energy CX10S-DCDBA0-P-A-DK00000 -
RFQ
ECAD 8034 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCDBA0-P-A-DK00000 EAR99 8504.40.9540 1 885W 5 93% 48V 24V 48V 12V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 4.17 A 15 A 21 A
CX10S-HHDBCB-P-A-DK00000 Advanced Energy CX10S-HHDBCB-P-A-DK00000 -
RFQ
ECAD 1406 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHDBCB-P-A-DK00000 EAR99 8504.40.9540 1 960W 8 93% 5V 24V 5V 24V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 4.17 A 15 A
NMP1K2-EKKEEE-04 MEAN WELL USA Inc. NMP1K2-EKKEEE-04 821.0300
RFQ
ECAD 7363 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 12V 48V 48V 12V 12V 12V - 4 kV 60601-1; 62368-1 20 A 5 A 5 A 20 A 20 A 20 A
CX10S-HACABC-P-A-DK00000 Advanced Energy CX10S-HACABC-P-A-DK00000 -
RFQ
ECAD 1492 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HACABC-P-A-DK00000 EAR99 8504.40.9540 1 890W 7 93% 5V 24V 5V 24V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 8.3 A 21 A 15 A
WX4-7711791-2-EL Vicor Corporation WX4-7711791-2-EL -
RFQ
ECAD 8707 0.00000000 Vicor Corporation - Bulk Obsolete - Not Applicable 1102-WX4-7711791-2-EL OBSOLETE 1
VP-D2364064 Vicor Corporation VP-D2364064 -
RFQ
ECAD 9318 0.00000000 Vicor Corporation * Bulk Obsolete VP-D - 1 (Unlimited) REACH Affected OBSOLETE 1
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse