SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-BHBDDA-P-A-DK00000 Advanced Energy CX10S-BHBDDA-P-A-DK00000 -
RFQ
ECAD 9642 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BHBDDA-P-A-DK00000 EAR99 8504.40.9540 1 965W 7 93% 12V 5V 24V 12V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 15 A 4.17 A 4.17 A
CX10S-CHGA0D-P-A-DK00000 Advanced Energy CX10S-CHGA0D-P-A-DK00000 -
RFQ
ECAD 3087 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHGA0D-P-A-DK00000 EAR99 8504.40.9540 1 725W 7 93% 24V 5V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 3 A 3 A 21 A
CX10S-CHGHGH-P-A-DK00000 Advanced Energy CX10S-CHGHGH-P-A-DK00000 -
RFQ
ECAD 1061 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHGHGH-P-A-DK00000 EAR99 8504.40.9540 1 740W 11 93% 24V 5V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 3 A 3 A 6 A
CX10S-00HA00-P-A-DK00000 Advanced Energy CX10S-00HA00-P-A-DK00000 -
RFQ
ECAD 1308 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00HA00-P-A-DK00000 EAR99 8504.40.9540 1 205W 3 93% 5V 24V 5V - - - No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A
CX10S-GHG0GC-P-A-DK00000 Advanced Energy CX10S-GHG0GC-P-A-DK00000 -
RFQ
ECAD 7835 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHG0GC-P-A-DK00000 EAR99 8504.40.9540 1 660W 9 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 3 A 3 A
CX10S-CGHHHG-P-A-DK00000 Advanced Energy CX10S-CGHHHG-P-A-DK00000 -
RFQ
ECAD 6341 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGHHHG-P-A-DK00000 EAR99 8504.40.9540 1 740W 11 93% 24V 24V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 6 A 3 A 6 A
CX10S-BACGHG-P-A-DK00000 Advanced Energy CX10S-BACGHG-P-A-DK00000 -
RFQ
ECAD 4156 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BACGHG-P-A-DK00000 EAR99 8504.40.9540 1 825W 9 93% 12V 5V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 8.3 A 3 A 3 A 6 A
CX10S-BC0GAH-P-A-DK00000 Advanced Energy CX10S-BC0GAH-P-A-DK00000 -
RFQ
ECAD 8290 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BC0GAH-P-A-DK00000 EAR99 8504.40.9540 1 505W 7 93% 12V 24V 24V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 3 A 3 A 21 A 6 A
CX10S-GHAACA-P-A-DK00000 Advanced Energy CX10S-GHAACA-P-A-DK00000 -
RFQ
ECAD 1240 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHAACA-P-A-DK00000 EAR99 8504.40.9540 1 735W 8 93% 24V 24V 5V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 21 A 21 A
CX10S-00CADD-P-A-DK00000 Advanced Energy CX10S-00CADD-P-A-DK00000 -
RFQ
ECAD 1335 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00CADD-P-A-DK00000 EAR99 8504.40.9540 1 705W 4 93% 24V 5V 48V 48V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 4.17 A 4.17 A
CX10S-AHC0GB-P-A-DK00000 Advanced Energy CX10S-AHC0GB-P-A-DK00000 -
RFQ
ECAD 4995 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AHC0GB-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 5V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 8.3 A 3 A 3 A
1010933CH Integrated Power Designs 1010933CH 477.6400
RFQ
ECAD 50 0.00000000 Integrated Power Designs NXT-400 (400W) Box Active 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 8.28" L x 4.00" W x 1.80" H (210.4mm x 101.6mm x 45.7mm) Chassis Mount Chassis Adjustable Output, Remote Sense, Universal Input 1010933 CE, cURus, TUV, UKCA 100 ~ 240 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6007 1 400W 1 85% 28V - - - - - - 60601-1; 62368-1 14.3 A
CX10S-GBG000-P-A-DK00000 Advanced Energy CX10S-GBG000-P-A-DK00000 -
RFQ
ECAD 6796 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBG000-P-A-DK00000 EAR99 8504.40.9540 1 420W 5 93% 24V 24V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 3 A 3 A
CX10S-GGB0BA-P-A-DK00000 Advanced Energy CX10S-GGB0BA-P-A-DK00000 -
RFQ
ECAD 4982 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGB0BA-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 24V 24V 24V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 15 A 15 A
CX10S-BGCCGG-P-A-DK00000 Advanced Energy CX10S-BGCCGG-P-A-DK00000 -
RFQ
ECAD 1854 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BGCCGG-P-A-DK00000 EAR99 8504.40.9540 1 940W 9 93% 12V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 8.3 A 8.3 A 3 A
SPN100-15S Kaga Electronics USA SPN100-15S -
RFQ
ECAD 8190 0.00000000 Kaga Electronics USA SPN100 (100W) Bulk Obsolete 0°C ~ 60°C (With Derating) ITE (Commercial) 7.36" L x 3.66" W x 1.54" H (187.0mm x 93.0mm x 39.0mm) Chassis Mount Enclosed Adjustable Output, DC Input Capable, PFC, Universal Input CE, CSA, cUL, UL 85 ~ 264 VAC download RoHS Compliant Not Applicable EAR99 8504.40.9580 10 100W 1 86% 15V - - - - - 3 kV 7 A
CX10S-BCA0CD-P-A-DK00000 Advanced Energy CX10S-BCA0CD-P-A-DK00000 -
RFQ
ECAD 9155 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCA0CD-P-A-DK00000 EAR99 8504.40.9540 1 685W 5 93% 12V 24V 5V 24V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 21 A 8.3 A 4.17 A
LEA75F-48-S Cosel USA, Inc. LEA75F-48-S -
RFQ
ECAD 6719 0.00000000 Cosel USA, Inc. LEA (75W) Box Obsolete -20°C ~ 70°C (With Derating) ITE (Commercial) 8.74" L x 2.17" W x 1.14" H (222.0mm x 55.0mm x 29.0mm) Chassis Mount Open Frame PFC, Universal Input LEA75F CE, cURus, TUV 85 ~ 264 VAC download ROHS3 Compliant Not Applicable EAR99 8504.40.9520 1 75W 1 86% 48V - - - - - 3 kV 1.6 A
VI-PU01-IUY Vicor Corporation VI-PU01-IUY 1.0000
RFQ
ECAD 2663 0.00000000 Vicor Corporation * Bulk Active VI-PU01 - RoHS non-compliant 1 (Unlimited) REACH Affected EAR99 8504.40.9530 1
CX10S-CC0CBB-P-A-DK00000 Advanced Energy CX10S-CC0CBB-P-A-DK00000 -
RFQ
ECAD 2005 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CC0CBB-P-A-DK00000 EAR99 8504.40.9540 1 760W 5 93% 24V 24V 24V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 8.3 A 15 A 15 A
NMP1K2-KKKKKC-00 MEAN WELL USA Inc. NMP1K2-KKKKKC-00 816.1200
RFQ
ECAD 5945 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 6 88.5% 48V 48V 48V 48V 48V 5V - 4 kV 60601-1; 62368-1 5 A 5 A 5 A 5 A 5 A 36 A
NLP250N-99S12J Artesyn Embedded Power NLP250N-99S12J -
RFQ
ECAD 9696 0.00000000 Artesyn Embedded Power NLP250-M (250W) Bulk Obsolete 0°C ~ 70°C (With Derating) ITE (Commercial), Medical 7.00" L x 4.00" W x 1.50" H (177.8mm x 101.6mm x 38.1mm) Chassis Mount Open Frame Adjustable Output, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NLP250 CB 85 ~ 264 VAC download RoHS Compliant 1 (Unlimited) EAR99 8504.40.6018 30 175W (250W Forced Air) 1 86% 12V - - - - No 3 kV 14.6 A
CX10S-H0ACDG-P-A-DK00000 Advanced Energy CX10S-H0ACDG-P-A-DK00000 -
RFQ
ECAD 2961 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H0ACDG-P-A-DK00000 EAR99 8504.40.9540 1 725W 7 93% 5V 24V 5V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 8.3 A 4.17 A 3 A
CX10S-HDBHGG-P-A-DK00000 Advanced Energy CX10S-HDBHGG-P-A-DK00000 -
RFQ
ECAD 7044 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDBHGG-P-A-DK00000 EAR99 8504.40.9540 1 820W 10 93% 5V 24V 48V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 15 A 6 A 3 A
CX10S-BHD0DH-P-A-DK00000 Advanced Energy CX10S-BHD0DH-P-A-DK00000 -
RFQ
ECAD 7715 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BHD0DH-P-A-DK00000 EAR99 8504.40.9540 1 780W 7 93% 12V 5V 24V 48V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 4.17 A 4.17 A 6 A
VI-PU44-EUU Vicor Corporation VI-PU44-EUU 1.0000
RFQ
ECAD 4350 0.00000000 Vicor Corporation * Bulk Active VI-PU44 - RoHS non-compliant 1 (Unlimited) REACH Affected EAR99 8504.40.9530 1
IMP4-2E0-1N0-1N0-1P0-00-A Artesyn Embedded Power IMP4-2E0-1N0-1N0-1P0-00-A -
RFQ
ECAD 2119 0.00000000 Artesyn Embedded Power iMP® (1158W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP4-2E0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download RoHS Compliant Not Applicable EAR99 8504.40.9540 1 930W 4 85% 5V 15V 15V 20V - - No 2 kV 60 A 14 A 14 A 10.5 A
NMP1K2-EEECCC-04 MEAN WELL USA Inc. NMP1K2-EEECCC-04 821.0300
RFQ
ECAD 5426 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 12V 12V 12V 5V 5V 5V - 4 kV 60601-1; 62368-1 20 A 20 A 20 A 36 A 36 A 36 A
DG200M-3EU Tri-Mag, LLC DG200M-3EU 124.9760
RFQ
ECAD 2852 0.00000000 Tri-Mag, LLC Tri-Mag, DG200 (200W) Box Active -20°C ~ 65°C (With Derating) Medical 5.00" L x 3.00" W x 1.42" H (127.0mm x 76.2mm x 36.1mm) Chassis Mount Open Frame PFC, Standby Output, Universal Input DG200 CB, CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) DG200M3EU EAR99 8504.40.6018 1 200W (300W Forced Air) 1 90% 18V - - - - No 4 kV 11.1 A
VI-QA23-EQV Vicor Corporation VI-QA23-EQV -
RFQ
ECAD 1720 0.00000000 Vicor Corporation * Bulk Obsolete VI-QA23 - Not Applicable REACH Affected EAR99 8504.40.9540 1
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse