Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
FL3-30-15668 | - | ![]() |
2129 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | - | Not Applicable | 1102-FL3-30-15668 | OBSOLETE | 1 | |||||||||||||||||||||||||||||||
![]() |
CX10S-AB00BC-P-A-DK00000 | - | ![]() |
6995 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AB00BC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 665W | 4 | 93% | 5V | 12V | 12V | 24V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 15 A | 15 A | 8.3 A | |||||
![]() |
CX10S-DH0BBA-P-A-DK00000 | - | ![]() |
5197 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-DH0BBA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 765W | 6 | 93% | 48V | 5V | 24V | 12V | 12V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 6 A | 3 A | 15 A | 15 A | 21 A | |||
![]() |
CX10S-GGDCBD-P-A-DK00000 | - | ![]() |
6610 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-GGDCBD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 8 | 93% | 24V | 24V | 24V | 24V | 48V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 3 A | 3 A | 4.17 A | 8.3 A | |||
![]() |
CX10S-0BHH0G-P-A-DK00000 | - | ![]() |
5895 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0BHH0G-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 500W | 7 | 93% | 12V | 5V | 24V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 6 A | 3 A | 6 A | 3 A | 3 A | |||
![]() |
CX10S-00CAHB-P-A-DK00000 | - | ![]() |
7128 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-00CAHB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 585W | 5 | 93% | 24V | 5V | 5V | 24V | 12V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 21 A | 6 A | 3 A | 15 A | ||||
![]() |
VP-A2535215E | - | ![]() |
7011 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VP-A | - | 1 (Unlimited) | REACH Affected | OBSOLETE | 1 | ||||||||||||||||||||||||||||||
![]() |
CX10S-AHCDAH-P-A-DK00000 | - | ![]() |
5086 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AHCDAH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 810W | 8 | 93% | 5V | 5V | 24V | 24V | 48V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 6 A | 3 A | 8.3 A | 4.17 A | 21 A | |||
![]() |
CX10S-BA0AAC-P-A-DK00000 | - | ![]() |
7407 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-BA0AAC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 695W | 5 | 93% | 12V | 5V | 5V | 5V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 21 A | 21 A | 21 A | 8.3 A | ||||
![]() |
VI-RU0MM-CYYY | - | ![]() |
2933 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-RU0MM | - | 1 (Unlimited) | REACH Affected | EAR99 | 8504.40.9510 | 1 | |||||||||||||||||||||||||||||
![]() |
CX10S-H00DCC-P-A-DK00000 | - | ![]() |
8817 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-H00DCC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 700W | 5 | 93% | 5V | 24V | 48V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 4.17 A | 8.3 A | 8.3 A | ||||
![]() |
CX10S-BHHC0C-P-A-DK00000 | - | ![]() |
6164 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-BHHC0C-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 780W | 7 | 93% | 12V | 5V | 24V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 6 A | 3 A | 6 A | 3 A | 8.3 A | |||
![]() |
CX10S-AGC0G0-P-A-DK00000 | - | ![]() |
1297 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AGC0G0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 545W | 6 | 93% | 5V | 24V | 24V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 3 A | 3 A | 8.3 A | 3 A | 3 A | |||
![]() |
CX10S-CADBAC-P-A-DK00000 | - | ![]() |
4080 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CADBAC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 990W | 6 | 93% | 24V | 5V | 48V | 12V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 21 A | 4.17 A | 15 A | 21 A | 8.3 A | |||
![]() |
NMP1K2-EHHH#H-02 | 733.5900 | ![]() |
7300 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 12V | 24V | 24V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 10 A | 10 A | |||||
![]() |
NMP1K2-CHKHEK-00 | 816.1200 | ![]() |
2001 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 5V | 24V | 48V | 24V | 12V | 48V | - | 4 kV | 60601-1; 62368-1 | 36 A | 10 A | 5 A | 10 A | 20 A | 5 A | ||
![]() |
CX10S-CHBHCC-P-A-DK00000 | - | ![]() |
8779 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CHBHCC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 980W | 8 | 93% | 24V | 5V | 24V | 12V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 6 A | 3 A | 15 A | 6 A | 3 A | |||
![]() |
ABC150-1012G | - | ![]() |
5150 | 0.00000000 | Bel Power Solutions | ABC150 (150W) | Box | Not For New Designs | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Standby Output, Universal Input | ABC150 | CE | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 24 | 110W (150W Forced Air) | 1 | 86% | 12V | - | - | - | - | No | 4.242 kV | 8.33 A | |||||||||
![]() |
CX10S-0GDB00-P-A-DK00000 | - | ![]() |
6591 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0GDB00-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 500W | 4 | 93% | 24V | 24V | 48V | 12V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 4.17 A | 15 A | |||||
![]() |
CX10S-ACGBCH-P-A-DK00000 | - | ![]() |
5023 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ACGBCH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 905W | 8 | 93% | 5V | 24V | 24V | 24V | 12V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 8.3 A | 3 A | 3 A | 15 A | 8.3 A | |||
![]() |
LFA150F-12-CJ1R2 | 101.5000 | ![]() |
2129 | 0.00000000 | Cosel USA, Inc. | LFA (150W) | Box | Active | -10°C ~ 70°C | ITE (Commercial) | 6.30" L x 2.95" W x 1.46" H (160.0mm x 74.9mm x 37.1mm) | Chassis Mount | Open Frame | LFA150F | CE, CSA, cURus, TUV, UL | 85 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | EAR99 | 8504.40.9520 | 1 | 1 | 85% | 12V | - | - | - | - | No | 3 kV | 60950-1; 62368-1 | 12.5 A | |||||||||||
![]() |
CX10S-G0HCBA-P-A-DK00000 | - | ![]() |
6110 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-G0HCBA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 705W | 7 | 93% | 24V | 24V | 5V | 24V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 6 A | 3 A | 8.3 A | 15 A | |||
![]() |
CX10S-HHAAAG-P-A-DK00000 | - | ![]() |
3923 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HHAAAG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 635W | 9 | 93% | 5V | 24V | 5V | 24V | 5V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 6 A | 3 A | 21 A | 21 A | |||
![]() |
NEVO+600ML-4054-DK000 | 420.2820 | ![]() |
7472 | 0.00000000 | Vox Power Ltd. | NEVO+600ML | Box | Active | -20°C ~ 70°C | Medical | 5.27" L x 3.06" W x 1.61" H (133.8mm x 77.7mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input | NEVO+600 | CB, CE, CSA, UL | 85 ~ 264 VAC, 120 ~ 300 VDC | download | Not Applicable | REACH Unaffected | 2050-NEVO+600ML-4054-DK000 | EAR99 | 8504.40.9530 | 1 | 450W | 4 | 86% | 48V | 12V | 12V | 48V | - | - | No | 4 kV | 60601-1 | 3.75 A | 5 A | 5 A | 3.75 A | ||||
![]() |
CX10S-CCBAA0-P-A-DK00000 | - | ![]() |
5608 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CCBAA0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 790W | 5 | 93% | 24V | 24V | 12V | 5V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 8.3 A | 15 A | 21 A | 21 A | ||||
![]() |
CX10S-GACBCG-P-A-DK00000 | - | ![]() |
7574 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-GACBCG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 925W | 8 | 93% | 24V | 24V | 5V | 24V | 12V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 21 A | 8.3 A | 15 A | 8.3 A | |||
![]() |
CX10S-GBC0BH-P-A-DK00000 | - | ![]() |
7277 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-GBC0BH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 780W | 7 | 93% | 24V | 24V | 12V | 24V | 12V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 15 A | 8.3 A | 15 A | 6 A | |||
![]() |
CX10S-DA0G0H-P-A-DK00000 | - | ![]() |
5456 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-DA0G0H-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 525W | 6 | 93% | 48V | 5V | 24V | 24V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 21 A | 3 A | 3 A | 6 A | 3 A | |||
![]() |
NMP1K2-CHKH#E-00 | 728.6700 | ![]() |
2353 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 5V | 24V | 48V | 24V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 10 A | 5 A | 10 A | 20 A | |||
![]() |
VI-QA01-EQW | - | ![]() |
6547 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-QA01 | - | Not Applicable | REACH Affected | EAR99 | 8504.40.9530 | 1 |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse