Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NMP1K2-HEECEK-00 | 816.1200 | ![]() |
6711 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 12V | 12V | 5V | 12V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 36 A | 20 A | 5 A | |
![]() |
NMP1K2-HEECH#-00 | 694.3000 | ![]() |
8125 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 12V | 12V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 36 A | 10 A | ||
![]() |
NMP1K2-HEECHK-00 | 777.6200 | ![]() |
9323 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 12V | 12V | 5V | 24V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 36 A | 10 A | 5 A | |
![]() |
NMP1K2-HEEEE#-00 | 728.6700 | ![]() |
3482 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 12V | 12V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 20 A | 20 A | ||
![]() |
NMP1K2-HK#HC#-00 | 641.2200 | ![]() |
3285 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 24V | 48V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 10 A | 36 A | ||||
![]() |
NMP1K2-HK#HKK-00 | 728.6700 | ![]() |
7523 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 48V | 24V | 48V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 10 A | 5 A | 5 A | ||
![]() |
NMP1K2-HK#K#H-00 | 641.2200 | ![]() |
3919 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 24V | 48V | 48V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 5 A | 10 A | ||||
![]() |
NMP1K2-HK#KEC-00 | 694.3000 | ![]() |
3200 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 48V | 48V | 12V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 5 A | 20 A | 36 A | ||
![]() |
NMP1K2-HK#KHC-00 | 728.6700 | ![]() |
7126 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 48V | 48V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 5 A | 10 A | 36 A | ||
![]() |
NMP1K2-HKC#HC-00 | 728.6700 | ![]() |
4136 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 48V | 5V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 10 A | 36 A | ||
![]() |
NMP1K2-HKCC#E-00 | 728.6700 | ![]() |
2990 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 48V | 5V | 5V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 36 A | 20 A | ||
![]() |
NMP1K2-HKCCCK-00 | 816.1200 | ![]() |
6266 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 5V | 5V | 5V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 36 A | 36 A | 5 A | |
![]() |
NMP1K2-HKCCHK-00 | 816.1200 | ![]() |
2667 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 5V | 5V | 24V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 36 A | 10 A | 5 A | |
![]() |
NMP1K2-HKCECC-00 | 816.1200 | ![]() |
1996 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 5V | 12V | 5V | 5V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 20 A | 36 A | 36 A | |
![]() |
NMP1K2-HKCECE-00 | 816.1200 | ![]() |
7021 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 5V | 12V | 5V | 12V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 20 A | 36 A | 20 A | |
![]() |
NMP1K2-HKCEHE-00 | 816.1200 | ![]() |
7295 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 5V | 12V | 24V | 12V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 20 A | 10 A | 20 A | |
![]() |
NMP1K2-HKCEKK-00 | 816.1200 | ![]() |
4680 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 5V | 12V | 48V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 20 A | 5 A | 5 A | |
![]() |
NMP1K2-HKCHC#-00 | 728.6700 | ![]() |
5287 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 48V | 5V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 10 A | 36 A | ||
![]() |
NMP1K2-HKCHE#-00 | 694.3000 | ![]() |
5360 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 48V | 5V | 24V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 10 A | 20 A | ||
![]() |
NMP1K2-HKCHEH-00 | 816.1200 | ![]() |
4550 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 5V | 24V | 12V | 24V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 10 A | 20 A | 10 A | |
![]() |
NMP1K2-HKCHEK-00 | 816.1200 | ![]() |
8857 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 5V | 24V | 12V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 10 A | 20 A | 5 A | |
![]() |
NMP1K2-HKCK#K-00 | 728.6700 | ![]() |
1954 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 48V | 5V | 48V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 5 A | 5 A | ||
![]() |
NMP1K2-HKCKEC-00 | 816.1200 | ![]() |
4497 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 5V | 48V | 12V | 5V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 5 A | 20 A | 36 A | |
![]() |
NMP1K2-HKCKKK-00 | 816.1200 | ![]() |
3173 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 5V | 48V | 48V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 36 A | 5 A | 5 A | 5 A | |
![]() |
NMP1K2-HKE#CC-00 | 694.3000 | ![]() |
9002 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 48V | 12V | 5V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 20 A | 36 A | 36 A | ||
![]() |
NMP1K2-HKE#HE-00 | 694.3000 | ![]() |
3517 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 48V | 12V | 24V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 20 A | 10 A | 20 A | ||
![]() |
NMP1K2-HKE#KE-00 | 728.6700 | ![]() |
7571 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 48V | 12V | 48V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 20 A | 5 A | 20 A | ||
![]() |
NMP1K2-HKECHK-00 | 816.1200 | ![]() |
4861 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 12V | 5V | 24V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 20 A | 36 A | 10 A | 5 A | |
![]() |
NMP1K2-HKEEEK-00 | 816.1200 | ![]() |
5561 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 48V | 12V | 12V | 12V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 20 A | 20 A | 20 A | 5 A | |
![]() |
NMP1K2-HKEEK#-00 | 694.3000 | ![]() |
5939 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 48V | 12V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 20 A | 20 A | 5 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse