Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NMP1K2-HCECCH-00 | 816.1200 | ![]() |
2094 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 5V | 12V | 5V | 5V | 24V | - | 4 kV | 60601-1; 62368-1 | 10 A | 36 A | 20 A | 36 A | 36 A | 10 A | |
![]() |
NMP1K2-HCEE#E-00 | 728.6700 | ![]() |
8119 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 5V | 12V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 36 A | 20 A | 20 A | 20 A | ||
![]() |
NMP1K2-H#ECCK-00 | 728.6700 | ![]() |
6844 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 12V | 5V | 5V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 36 A | 36 A | 5 A | ||
![]() |
NMP1K2-H#ECEE-00 | 728.6700 | ![]() |
8622 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 12V | 5V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 36 A | 20 A | 20 A | ||
![]() |
NMP1K2-H#ECEK-00 | 694.3000 | ![]() |
6739 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 12V | 5V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 36 A | 20 A | 5 A | ||
![]() |
NMP1K2-H#ECK#-00 | 610.9800 | ![]() |
6183 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 24V | 12V | 5V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 36 A | 5 A | ||||
![]() |
NMP1K2-H#EE#C-00 | 641.2200 | ![]() |
1968 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 24V | 12V | 12V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 36 A | ||||
![]() |
NMP1K2-H#EEC#-00 | 641.2200 | ![]() |
3267 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 24V | 12V | 12V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 36 A | ||||
![]() |
NMP1K2-H#EECH-00 | 728.6700 | ![]() |
2305 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 12V | 12V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 36 A | 10 A | ||
![]() |
NMP1K2-H#EEE#-00 | 641.2200 | ![]() |
9905 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 24V | 12V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 20 A | ||||
![]() |
NMP1K2-H#EEKC-00 | 728.6700 | ![]() |
7104 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 12V | 12V | 48V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 5 A | 36 A | ||
![]() |
NMP1K2-H#EHKC-00 | 728.6700 | ![]() |
7404 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 12V | 24V | 48V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 10 A | 5 A | 36 A | ||
![]() |
NMP1K2-H#EK##-00 | 553.7800 | ![]() |
1679 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 720W | 3 | 88.5% | 24V | 12V | 48V | - | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 5 A | |||||
![]() |
NMP1K2-H#EK#K-00 | 641.2200 | ![]() |
2083 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 24V | 12V | 48V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 5 A | 5 A | ||||
![]() |
NMP1K2-H#H#HC-00 | 641.2200 | ![]() |
7182 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 24V | 24V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 10 A | 36 A | ||||
![]() |
NMP1K2-H#H#HH-00 | 610.9800 | ![]() |
9012 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 24V | 24V | 24V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 10 A | 10 A | ||||
![]() |
NMP1K2-H#HC#H-00 | 641.2200 | ![]() |
5732 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 24V | 24V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 10 A | ||||
![]() |
NMP1K2-H#HC#K-00 | 610.9800 | ![]() |
5462 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 24V | 24V | 5V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 5 A | ||||
![]() |
NMP1K2-H#HCEK-00 | 728.6700 | ![]() |
2776 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 24V | 5V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 5 A | ||
![]() |
NMP1K2-H#HCKC-00 | 694.3000 | ![]() |
2090 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 24V | 5V | 48V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 5 A | 36 A | ||
![]() |
NMP1K2-H#HCKE-00 | 694.3000 | ![]() |
8280 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 24V | 5V | 48V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 5 A | 20 A | ||
![]() |
NMP1K2-H#HEKH-00 | 694.3000 | ![]() |
2302 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 24V | 12V | 48V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 20 A | 5 A | 10 A | ||
![]() |
NMP1K2-H#HH##-00 | 553.7800 | ![]() |
1290 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 720W | 3 | 88.5% | 24V | 24V | 24V | - | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 10 A | |||||
![]() |
NMP1K2-H#HHCC-00 | 694.3000 | ![]() |
3939 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 24V | 24V | 5V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 10 A | 36 A | 36 A | ||
![]() |
NMP1K2-H#HHCH-00 | 728.6700 | ![]() |
7787 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 24V | 24V | 5V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 10 A | 36 A | 10 A | ||
![]() |
NMP1K2-H#HHCK-00 | 728.6700 | ![]() |
5845 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 24V | 24V | 5V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 10 A | 36 A | 5 A | ||
![]() |
NMP1K2-H#HK#K-00 | 641.2200 | ![]() |
4288 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 24V | 24V | 48V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 5 A | 5 A | ||||
![]() |
NMP1K2-H#HKHC-00 | 694.3000 | ![]() |
2859 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 24V | 24V | 48V | 24V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 5 A | 10 A | 36 A | ||
![]() |
NMP1K2-H#K##K-00 | 553.7800 | ![]() |
1629 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 720W | 3 | 88.5% | 24V | 48V | 48V | - | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 5 A | |||||
![]() |
NMP1K2-H#K#HK-00 | 641.2200 | ![]() |
1164 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 4 | 88.5% | 24V | 48V | 24V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 10 A | 5 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse