Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Ratings | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | Termination Style | Voltage - Input (Max) | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Topology | Dimming | Voltage - Output | Current - Output (Max) | Voltage - Input (Min) | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | SIC Programmable |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NMP1K2-CC#C##-01 | 558.7000 | ![]() |
1922 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 540W | 2 | 88.5% | 5V | 5V | - | - | - | - | 4 kV | 60601-1; 62368-1 | 72 A | 36 A | |||||||||||||||
![]() |
NMP1K2-HKKKCE-03 | 821.0300 | ![]() |
8415 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 48V | 48V | 48V | 5V | 12V | - | 4 kV | 60601-1; 62368-1 | 10 A | 5 A | 5 A | 5 A | 36 A | 20 A | ||||||||||
![]() |
RSP-150-7.5 | 48.0200 | ![]() |
35 | 0.00000000 | MEAN WELL USA Inc. | RSP-150 (150W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial) | 7.83" L x 3.90" W x 1.18" H (199.0mm x 99.0mm x 30.0mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Remote On/Off, Universal Input | RSP-150 | CB, CCC, CE, cURus, TUV | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 24 | 150W | 1 | 88.5% | 7.5V | - | - | - | - | No | 4 kV | 20 A | |||||||||||||||||
![]() |
NMP1K2-K#KK#E-03 | 646.1400 | ![]() |
7173 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 3 | 88.5% | 48V | 48V | 12V | - | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 10 A | 20 A | ||||||||||||||
![]() |
NMP1K2-CHK##C-00 | 641.2200 | ![]() |
1657 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 840W | 4 | 88.5% | 5V | 24V | 48V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 10 A | 5 A | 36 A | |||||||||||||
![]() |
NMP1K2-HEE#EE-05 | 733.5900 | ![]() |
1102 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 24V | 12V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 20 A | 40 A | |||||||||||||
![]() |
NMP1K2-HHCEHC-00 | 816.1200 | ![]() |
1491 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 24V | 24V | 5V | 12V | 24V | 5V | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 36 A | 20 A | 10 A | 36 A | ||||||||||
![]() |
NMP1K2-CCCK#E-06 | 701.2100 | ![]() |
3073 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1020W | 3 | 88.5% | 5V | 48V | 12V | - | - | - | 4 kV | 60601-1; 62368-1 | 108 A | 5 A | 20 A | ||||||||||||||
![]() |
NMP1K2-HHEEEE-08 | 823.3700 | ![]() |
1154 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 24V | 24V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 60 A | 20 A | |||||||||||||
![]() |
NMP1K2-#CHEHK-00 | 728.6700 | ![]() |
2230 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 5V | 24V | 12V | 24V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 10 A | 20 A | 10 A | 5 A | |||||||||||
![]() |
HLG-40H-42B | 41.8300 | ![]() |
28 | 0.00000000 | MEAN WELL USA Inc. | HLG-40H (40W) | Box | Active | -40°C ~ 80°C | IP67 | 5.80" L x 2.42" W x 1.45" H (147.2mm x 61.5mm x 36.8mm) | Chassis Mount | Constant Current, Voltage | OCP, OTP, OVP, SCP | HLG-40H | CB, CCC, CE, cURus, PSE, RCM, TUV | Wire Leads | 305VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 20 | 40 W | 1 | AC DC Converter | Analog, PWM | 25.2 ~ 42V | 960mA | 90VAC | 88.5% | 3.75 kV | Not Verified | |||||||||||||||||
![]() |
PLC-45-20 | 38.2740 | ![]() |
2161 | 0.00000000 | MEAN WELL USA Inc. | PLC-45 (45W) | Box | Not For New Designs | -30°C ~ 50°C | - | 7.15" L x 2.44" W x 1.38" H (181.5mm x 62.0mm x 35.0mm) | Chassis Mount | Constant Current | OCP, OTP, OVP, SCP | PLC-45 | CB, CCC, CE, cURus, ENEC, PSE, TUV | Terminal Block | 264VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 30 | 46 W | 1 | AC DC Converter | - | 15 ~ 20V | 2.3A | 90VAC | 86.5% | 3.75 kV | Not Verified | |||||||||||||||||
![]() |
NMP1K2-#HCCHE-03 | 733.5900 | ![]() |
4640 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 4 | 88.5% | 24V | 5V | 24V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 72 A | 10 A | 20 A | |||||||||||||
![]() |
NMP1K2-HCCHEK-02 | 821.0300 | ![]() |
2179 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 5V | 5V | 24V | 12V | 48V | - | 4 kV | 60601-1; 62368-1 | 10 A | 36 A | 36 A | 10 A | 20 A | 5 A | ||||||||||
![]() |
NMP1K2-HHHCKH-06 | 823.3700 | ![]() |
4513 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 24V | 5V | 48V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 30 A | 36 A | 5 A | 10 A | |||||||||||||
![]() |
NMP1K2-HECCHH-05 | 821.0300 | ![]() |
9334 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 24V | 12V | 5V | 5V | 24V | 24V | - | 4 kV | 60601-1; 62368-1 | 10 A | 20 A | 36 A | 36 A | 10 A | 10 A | ||||||||||
![]() |
NMP1K2-EC#CEK-00 | 728.6700 | ![]() |
3561 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 12V | 5V | 5V | 12V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 36 A | 36 A | 20 A | 5 A | |||||||||||
![]() |
NMP1K2-KKHH#H-03 | 733.5900 | ![]() |
8860 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 4 | 88.5% | 48V | 48V | 24V | 24V | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 5 A | 20 A | 10 A | |||||||||||||
![]() |
NMP1K2-##KKK#-04 | 558.7000 | ![]() |
1757 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 720W | 2 | 88.5% | 48V | 48V | - | - | - | - | 4 kV | 60601-1; 62368-1 | 5 A | 10 A | |||||||||||||||
![]() |
NMP1K2-CEKKK#-04 | 733.5900 | ![]() |
1893 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 4 | 88.5% | 5V | 12V | 48V | 48V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 20 A | 5 A | 10 A | |||||||||||||
![]() |
NMP1K2-CKEEEH-04 | 821.0300 | ![]() |
8541 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 5 | 88.5% | 5V | 48V | 12V | 12V | 12V | 24V | - | 4 kV | 60601-1; 62368-1 | 36 A | 5 A | 20 A | 20 A | 20 A | 10 A | ||||||||||
![]() |
NMP1K2-EECCHK-00 | 816.1200 | ![]() |
6909 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 12V | 12V | 5V | 5V | 24V | 48V | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 36 A | 36 A | 10 A | 5 A | ||||||||||
![]() |
NMP1K2-HHCCC#-01 | 733.5900 | ![]() |
1308 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1020W | 4 | 88.5% | 24V | 5V | 5V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 36 A | 36 A | 36 A | |||||||||||||
![]() |
NMP1K2-#H#KKH-04 | 646.1400 | ![]() |
4764 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 960W | 3 | 88.5% | 24V | 48V | 24V | - | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 10 A | 10 A | ||||||||||||||
![]() |
NMP1K2-ECCHHK-00 | 816.1200 | ![]() |
1353 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1200W | 6 | 88.5% | 12V | 5V | 5V | 24V | 24V | 48V | - | 4 kV | 60601-1; 62368-1 | 20 A | 36 A | 36 A | 10 A | 10 A | 5 A | ||||||||||
![]() |
NMP1K2-C#CK#C-00 | 641.2200 | ![]() |
6996 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 780W | 4 | 88.5% | 5V | 5V | 48V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 36 A | 5 A | 36 A | |||||||||||||
![]() |
NFM-10-15 | - | ![]() |
7461 | 0.00000000 | MEAN WELL USA Inc. | NFM-10 (10W) | Tray | Obsolete | -20°C ~ 70°C (With Derating) | Medical | 2.56" L x 1.77" W x 0.87" H (65.0mm x 45.0mm x 22.0mm) | Chassis Mount | Open Frame | Adjustable Output, Universal Input | CB, CE, cURus, TUV | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 10W | 1 | 79% | 15V | - | - | - | - | No | 4 kV | 670 mA | ||||||||||||||||||
![]() |
NMP1K2-E#EEC#-00 | 610.9800 | ![]() |
9566 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 900W | 4 | 88.5% | 12V | 12V | 12V | 5V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 20 A | 36 A | |||||||||||||
![]() |
NMP1K2-ECCEE#-02 | 733.5900 | ![]() |
6900 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 4 | 88.5% | 12V | 5V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 72 A | 20 A | 20 A | |||||||||||||
![]() |
NMP1K2-HCC#KE-00 | 728.6700 | ![]() |
7551 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1080W | 5 | 88.5% | 24V | 5V | 5V | 48V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 10 A | 36 A | 36 A | 5 A | 20 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse