SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Control Features Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation Standard Number Line Regulation Load Regulation
TMR 3-0512 Traco Power TMR 3-0512 21.5200
RFQ
ECAD 438 0.00000000 Traco Power TMR 3 (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 9V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2362 EAR99 8504.40.9580 10 3 W 1 250mA 4.5V 81% 12V - - - 1.6 kV
TEP 100-7215WIR Traco Power TEP 100-7215WIR 199.4500
RFQ
ECAD 5571 0.00000000 Traco Power TEP 100WIR (100W) Box Active -40°C ~ 75°C (With Derating) ITE (Commercial), Railway 2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP, UVLO TEP 100 160V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 101 W 1 4.2A 43V 90% 24V - - - 3 kV
TMR 3-4811E Traco Power TMR 3-4811E 16.8400
RFQ
ECAD 10 0.00000000 Traco Power TMR 3E (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.37" W x 0.44" H (21.8mm x 9.3mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 1 600mA 36V 78% 5V - - - 1.5 kV
TMV 2-1205DHI Traco Power TMV 2-1205DHI 12.6090
RFQ
ECAD 7136 0.00000000 Traco Power TMV 2HI (2W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.5mm x 10.2mm) Through Hole 7-SIP Module, 5 Leads Isolated Module SCP TMV 2 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 2 200mA, 200mA 10.8V 79% 5V -5V - - 5.2 kV
TDR 2-2412SM Traco Power TDR 2-2412SM 27.2000
RFQ
ECAD 192 0.00000000 Traco Power TDR 2SM (2W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.74" L x 0.50" W x 0.34" H (18.9mm x 12.8mm x 8.7mm) Surface Mount 14-SMD Module, 7 Leads Isolated Module Remote On/Off, SCP TDR 2 36V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected EAR99 8504.40.9580 10 2 W 1 167mA 18V 84% 12V - - - 1.6 kV
THM 15-1213 Traco Power THM 15-1213 59.7900
RFQ
ECAD 8385 0.00000000 Traco Power THM 15 (15W) Tube Active -40°C ~ 85°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 15 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1628 EAR99 8504.40.9580 10 15 W 1 1A 9V 89% 15V - - - 5 kV
TMR 2-2423WI Traco Power TMR 2-2423WI 20.4500
RFQ
ECAD 50 0.00000000 Traco Power TMR 2WI (2W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.02" L x 0.37" W x 0.49" H (26.0mm x 9.3mm x 12.5mm) Through Hole 9-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 2 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2355 EAR99 8504.40.9580 10 2 W 2 65mA, 65mA 9V 79% 15V -15V - - 1.5 kV
TMPW 25-124 Traco Power TMPW 25-124 25.8500
RFQ
ECAD 20 0.00000000 Traco Power TMPW 25 (25W) Box Active -40°C ~ 70°C (With Derating) Household Appliances, ITE (Commercial) 2.07" L x 1.08" W x 0.93" H (52.5mm x 27.5mm x 23.5mm) Through Hole 4-DIP Module Enclosed - TMPW 25 CB, cURus 90 ~ 305 VAC, 100 ~ 250 VDC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-TMPW25-124 EAR99 8504.40.9510 10 25 W 1 1.042A 87% 24V - - - - -
TPP 15-103A-D Traco Power TPP 15-103A-D 39.5600
RFQ
ECAD 11 0.00000000 Traco Power TPP 15A-D (15W) Box Active -40°C ~ 85°C (With Derating) Household Appliances, ITE (Commercial), Medical 1.50" L x 1.00" W x 0.82" H (38.1mm x 25.4mm x 20.8mm) Through Hole 5-DIP Module Open Frame Adjustable Output, Universal Input TPP 15 CB, CE, cURus 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2880 EAR99 8504.40.9510 1 13 W 1 4A 84% 3.3V - - - - 0.70%
TEN 8-2421 Traco Power TEN 8-2421 33.2900
RFQ
ECAD 479 0.00000000 Traco Power TEN 8 (8W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.26" L x 0.80" W x 0.40" H (32.0mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, SCP TEN 8 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2570 EAR99 8504.40.9580 10 8 W 2 800mA, 800mA 18V 82% 5V -5V - - 1.5 kV
TEC 2-0919 Traco Power TEC 2-0919 10.7900
RFQ
ECAD 11 0.00000000 Traco Power TEC 2 (2W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TEC 2 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1386 EAR99 8504.40.9580 10 2 W 1 222mA 4.5V 84% 9V - - - 1.6 kV
TSR 3-24150A Traco Power TSR 3-24150A 32.4000
RFQ
ECAD 1 0.00000000 Traco Power TSR-3 Box Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.65" L x 0.41" W x 0.24" H (16.5mm x 10.4mm x 6.2mm) Through Hole 5-SIP Module Linear Regulator Replacement Remote On/Off, SCP TSR 3 30V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 45 W 1 3A 10V 95% 5 ~ 15V - - -
THD 15-4811WIN Traco Power THD 15-4811WIN 55.2400
RFQ
ECAD 200 0.00000000 Traco Power THD 15WIN (15W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 8 Leads Isolated Module Remote On/Off, OVP, SCP THD 15 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 15 W 1 3A 18V 89% 5.1V - - - 1.5 kV
TRN 1-4823 Traco Power TRN 1-4823 11.5850
RFQ
ECAD 5638 0.00000000 Traco Power TRN 1 (1W) Tube Active -40°C ~ 90°C ITE (Commercial) 0.47" L x 0.30" W x 0.43" H (11.9mm x 7.7mm x 11.0mm) Through Hole 5-SIP Module Isolated Module SCP TRN 1 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 1.1 W 2 35mA, 35mA 36V 79% 15V -15V - - 1.6 kV
THL 30-4810WI Traco Power THL 30-4810WI 57.6900
RFQ
ECAD 10 0.00000000 Traco Power THL 30WI (30W) Tube Active -40°C ~ 80°C ITE (Commercial) 1.00" L x 1.00" W x 0.40" H (25.4mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Adjustable Output, Remote On/Off CB, cURus 75V - download ROHS3 Compliant 1 (Unlimited) 1951-THL30-4810WI EAR99 8504.40.9580 10 23 W 1 - 7A 18V 87% 3.3V - - - 1.8 kV 62368-1
TEN 40-7215WIR Traco Power TEN 40-7215WIR 112.7900
RFQ
ECAD 156 0.00000000 Traco Power TEN 40WIR (40W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO TEN 40 160V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2187 EAR99 8504.40.9580 10 40 W 1 1.666A 43V 90% 24V - - - 1.6 kV
TMV 2-1212SHI Traco Power TMV 2-1212SHI 11.6800
RFQ
ECAD 2834 0.00000000 Traco Power TMV 2HI (2W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.5mm x 10.2mm) Through Hole 7-SIP Module, 4 Leads Isolated Module SCP TMV 2 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 1 168mA 10.8V 83% 12V - - - 5.2 kV
THM 3-1223 Traco Power THM 3-1223 43.3600
RFQ
ECAD 4971 0.00000000 Traco Power THM 3 (3W) Tube Active -40°C ~ 90°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module OCP, OVP, SCP THM 3 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 9V 86.5% 15V -15V - - 5 kV
THD 10-2413WIN Traco Power THD 10-2413WIN 30.8100
RFQ
ECAD 10 0.00000000 Traco Power THD 10WIN (10W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, SCP THD 10 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 10 W 1 666mA 9V 87% 15V - - - 1.5 kV
TMR 9-2419 Traco Power TMR 9-2419 37.8300
RFQ
ECAD 80 0.00000000 Traco Power TMR 9 (9W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module, 6 Leads Isolated Module Remote On/Off, SCP TMR 9 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 9 W 1 1A 18V 88% 9V - - - 1.6 kV
THM 30-4822 Traco Power THM 30-4822 91.7260
RFQ
ECAD 1376 0.00000000 Traco Power THM 30 (30W) Tube Active -40°C ~ 80°C (With Derating) Medical 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 30 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1687 EAR99 8504.40.9580 10 30 W 2 1.25A, 1.25A 36V 90% 12V -12V - - 5 kV
THM 10-2412WI Traco Power THM 10-2412WI 64.0600
RFQ
ECAD 821 0.00000000 Traco Power THM 10WI (10W) Tube Active -40°C ~ 90°C (With Derating) Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module OCP, OVP, SCP THM 10 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2276 EAR99 8504.40.9580 10 10 W 1 830mA 9V 89% 12V - - - 5 kV
TMR 6-2410 Traco Power TMR 6-2410 23.7400
RFQ
ECAD 16 0.00000000 Traco Power TMR 6 (6W) Tube Active -40°C ~ 65°C ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 6 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2394 EAR99 8504.40.9580 10 4.3 W 1 1.3A 18V 78% 3.3V - - - 1.6 kV
TRI 10-4812 Traco Power TRI 10-4812 60.3600
RFQ
ECAD 2 0.00000000 Traco Power TRI 10 (10W) Tube Active -40°C ~ 85°C ITE (Commercial) 1.25" L x 0.80" W x 0.47" H (31.8mm x 20.3mm x 12.0mm) Through Hole 24-DIP Module, 5 Leads Isolated Module - TRI 10 CB, cURus 75V - download ROHS3 Compliant Not Applicable REACH Unaffected TRI10-4812 EAR99 8504.40.9580 10 10 W 1 - 833mA 36V 87% 12V - - - 5 kV
TOS 06-12SM Traco Power TOS 06-12SM 22.4000
RFQ
ECAD 50 0.00000000 Traco Power TOS Tube Active -40°C ~ 85°C ITE (Commercial) 1.30" L x 0.53" W x 0.33" H (33.0mm x 13.5mm x 8.3mm) Surface Mount 5-SMD Module Non-Isolated PoL Module Remote On/Off, OCP, OTP, SCP TOS 06 14V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected 1951-2414 EAR99 8504.40.9580 10 30 W 1 6A 8.3V 89% 0.75 ~ 5V - - -
TIM 3.5-4812SM Traco Power TIM 3.5-4812SM 40.0100
RFQ
ECAD 16 0.00000000 Traco Power TIM 3.5SM (3.5W) Tube Active -40°C ~ 90°C (With Derating) Medical 0.96" L x 0.57" W x 0.41" H (24.3mm x 14.4mm x 10.5mm) Surface Mount 16-SMD Module, 7 Leads Isolated Module Remote On/Off, OVP, SCP TIM 3.5 75V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected 1951-1976 EAR99 8504.40.9580 10 3.5 W 1 292mA 36V 81% 12V - - - 5 kV
TEC 3-4812WI Traco Power TEC 3-4812WI 15.5100
RFQ
ECAD 3047 0.00000000 Traco Power TEC 3WI (3W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TEC 3 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1494 EAR99 8504.40.9580 10 3 W 1 250mA 18V 82% 12V - - - 1.6 kV
TRI 3-4811 Traco Power TRI 3-4811 39.7990
RFQ
ECAD 6082 0.00000000 Traco Power TRI 3 (3.5W) Tube Active -40°C ~ 96°C ITE (Commercial) 1.25" L x 0.80" W x 0.47" H (31.8mm x 20.3mm x 12.0mm) Through Hole 24-DIP Module, 5 Leads Isolated Module - TRI 3 CB, cURus 75V - download ROHS3 Compliant Not Applicable REACH Unaffected TRI3-4811 EAR99 8504.40.9580 10 3.5 W 1 - 700mA 36V 82% 5V - - - 9 kV
THN 20-4812 Traco Power THN 20-4812 46.6900
RFQ
ECAD 6820 0.00000000 Traco Power THN 20 (20W) Tube Active -40°C ~ 75°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP THN 20 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 20 W 1 1.67A 36V 90% 12V - - - 1.5 kV
TBA 1-0519HI Traco Power TBA 1-0519HI 4.0400
RFQ
ECAD 2 0.00000000 Traco Power TBA 1HI (1W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.24" W x 0.39" H (19.5mm x 6.0mm x 10.0mm) Through Hole 7-SIP Module, 4 Leads Isolated Module SCP TBA 1 - 5.5V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 999 mW 1 111mA 4.5V 80% 9V - - - 3 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse