SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation Line Regulation Load Regulation
TMLM 10124 Traco Power TMLM 10124 -
RFQ
ECAD 7769 0.00000000 Traco Power TMLM (10W) Box Obsolete -25°C ~ 60°C (With Derating) ITE (Commercial) 2.06" L x 1.07" W x 0.93" H (52.4mm x 27.2mm x 23.5mm) Through Hole 4-DIP Module Enclosed Universal Input CE, cURus 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1291 EAR99 8504.40.9510 10 10 W 1 417mA 80% 24V - - - 0.3% ±0.5%
TRN 3-1211SM Traco Power TRN 3-1211SM 22.1800
RFQ
ECAD 4 0.00000000 Traco Power TRN 3SM (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.47" L x 0.44" W x 0.31" H (11.9mm x 11.3mm x 8.0mm) Surface Mount 7-SMD Module, 6 Leads Isolated Module SCP TRN 3 18V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 3 W 1 600mA 9V 79% 5V - - - 1.6 kV
TOS 10-12SM Traco Power TOS 10-12SM 31.2000
RFQ
ECAD 22 0.00000000 Traco Power TOS Tube Active -40°C ~ 85°C ITE (Commercial) 1.30" L x 0.53" W x 0.33" H (33.0mm x 13.5mm x 8.3mm) Surface Mount 5-SMD Module Non-Isolated PoL Module Remote On/Off, OCP, OTP, SCP TOS 10 14V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected 1951-1811 EAR99 8504.40.9580 10 50 W 1 10A 8.3V 93% 0.75 ~ 5V - - -
TDL 2-0511 Traco Power TDL 2-0511 18.9500
RFQ
ECAD 4920 0.00000000 Traco Power TDL 2 (2W) Tube Not For New Designs -40°C ~ 70°C ITE (Commercial) 0.55" L x 0.55" W x 0.31" H (14.0mm x 14.0mm x 8.0mm) Through Hole 7-DIP Module, 4 Leads Isolated Module SCP TDL 2 10V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 1 400mA 4.5V 81% 5V - - - 1.5 kV
THL 3-4812WISM Traco Power THL 3-4812WISM 22.7980
RFQ
ECAD 3336 0.00000000 Traco Power THL 3WISM (3W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 0.94" L x 0.54" W x 0.32" H (24.0mm x 13.7mm x 8.3mm) Surface Mount 16-SMD Module, 7 Leads Isolated Module Remote On/Off, SCP THL 3 75V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected EAR99 8504.40.9580 10 3 W 1 250mA 18V 80% 12V - - - 1.5 kV
TMR 3-1222E Traco Power TMR 3-1222E 17.1800
RFQ
ECAD 2 0.00000000 Traco Power TMR 3E (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.37" W x 0.44" H (21.8mm x 9.3mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 2 125mA, 125mA 9V 83% 12V -12V - - 1.5 kV
TSR 0.5-2418 Traco Power TSR 0.5-2418 6.8600
RFQ
ECAD 10 0.00000000 Traco Power TSR 0.5 Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.45" L x 0.30" W x 0.40" H (11.5mm x 7.6mm x 10.2mm) Through Hole 3-SIP Module Linear Regulator Replacement OTP, SCP TSR 0.5 32V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 900 mW 1 500mA 4.75V 82% 1.8V - - -
TEL 5-2422 Traco Power TEL 5-2422 21.7400
RFQ
ECAD 188 0.00000000 Traco Power TEL 5 (5W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 23-DIP Module, 8 Leads Isolated Module SCP TEL 5 36V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2544 EAR99 8504.40.9580 10 6 W 2 250mA, 250mA 18V 86% 12V -12V - - 1.5 kV
THM 3-2412 Traco Power THM 3-2412 42.0200
RFQ
ECAD 15 0.00000000 Traco Power THM 3 (3W) Tube Active -40°C ~ 90°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module OCP, OVP, SCP THM 3 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 1 250mA 9V 87% 12V - - - 5 kV
TEN 15-1211 Traco Power TEN 15-1211 52.4000
RFQ
ECAD 4228 0.00000000 Traco Power TEN 15 (15W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module, 4 Leads Isolated Module OCP, OVP, SCP TEN 15 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 15 W 1 3A 9V 82% 5V - - - 1.6 kV
TMR 9-2422WI Traco Power TMR 9-2422WI 44.5700
RFQ
ECAD 10 0.00000000 Traco Power TMR 9WI (9W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module, 6 Leads Isolated Module Remote On/Off, SCP TMR 9 CB, cURus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 9 W 2 375mA, 375mA 9V 88% 12V -12V - - 1.6 kV
TEN 20-2410WIN Traco Power TEN 20-2410WIN 58.7000
RFQ
ECAD 59 0.00000000 Traco Power TEN 20WIN (20W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP TEN 20 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2122 EAR99 8504.40.9580 10 18 W 1 5.5A 9V 85% 3.3V - - - 1.5 kV
TSR 1-2450 Traco Power TSR 1-2450 6.1500
RFQ
ECAD 22 0.00000000 Traco Power TSR 1 Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.46" L x 0.30" W x 0.40" H (11.7mm x 7.5mm x 10.1mm) Through Hole 3-SIP Module Linear Regulator Replacement SCP TSR 1 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2747 EAR99 8504.40.9580 10 5 W 1 1A 6.5V 94% 5V - - -
THM 10-4812 Traco Power THM 10-4812 52.4300
RFQ
ECAD 26 0.00000000 Traco Power THM 10 (10W) Tube Active -40°C ~ 90°C (With Derating) Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module OCP, OVP, SCP THM 10 CB, cURus 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 10 W 1 830mA 36V 89% 12V - - - 5 kV
TEN 20-2412 Traco Power TEN 20-2412 65.4200
RFQ
ECAD 39 0.00000000 Traco Power TEN 20 (20W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module SCP TEN 20 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2124 EAR99 8504.40.9580 10 20 W 1 1.67A 18V 89% 12V - - - 1.5 kV
TES 1-0522V Traco Power TES 1-0522V 11.5500
RFQ
ECAD 10 0.00000000 Traco Power TES 1V (1W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.64" L x 0.31" W x 0.31" H (16.3mm x 8.0mm x 8.0mm) Surface Mount 12-SMD Module, 10 Leads Isolated Module SCP TES 1 5.5V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 1 W 2 42mA, 42mA 4.5V 79% 12V -12V - - 3 kV
TEN 8-4813 Traco Power TEN 8-4813 32.6600
RFQ
ECAD 15 0.00000000 Traco Power TEN 8 (8W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.26" L x 0.80" W x 0.40" H (32.0mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, SCP TEN 8 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2229 EAR99 8504.40.9580 10 8 W 1 535mA 36V 86% 15V - - - 1.5 kV
TSR 0.5-2490 Traco Power TSR 0.5-2490 6.7900
RFQ
ECAD 13 0.00000000 Traco Power TSR 0.5 Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.45" L x 0.30" W x 0.40" H (11.5mm x 7.6mm x 10.2mm) Through Hole 3-SIP Module Linear Regulator Replacement OTP, SCP TSR 0.5 32V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2522 EAR99 8504.40.9580 10 4.5 W 1 500mA 11V 96% 9V - - -
TMM 60105C Traco Power TMM 60105C 110.0600
RFQ
ECAD 5 0.00000000 Traco Power TMM 60 (60W) Box Active -40°C ~ 75°C (With Derating) Industrial, ITE (Commercial), Medical 4.41" L x 2.57" W x 1.50" H (112.0mm x 65.3mm x 38.1mm) Through Hole Enclosed Adjustable Output, Universal Input TMM 60105 CB, CE, cULus, cURus 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9520 5 1 84% 5.1V - - -
TEC 2-4822WI Traco Power TEC 2-4822WI 12.7700
RFQ
ECAD 9 0.00000000 Traco Power TEC 2WI (2W) Tube Active -40°C ~ 93°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TEC 2 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1441 EAR99 8504.40.9580 10 2 W 2 83mA, 83mA 18V 81% 12V -12V - - 1.6 kV
TMP 60136 Traco Power TMP 60136 76.8240
RFQ
ECAD 4906 0.00000000 Traco Power TMP (60W) Box Active -25°C ~ 70°C (With Derating) ITE (Commercial) 3.50" L x 2.66" W x 1.35" H (88.9mm x 67.5mm x 34.2mm) Through Hole 6-DIP Module, 4 Leads Enclosed Universal Input TMP 60 CB, CE, cULus, cURus 85 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9520 5 60 W 1 1.665A 84% 36V - - - - -
TMA 1505D Traco Power TMA 1505D 5.7700
RFQ
ECAD 7 0.00000000 Traco Power TMA (1W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.77" L x 0.24" W x 0.40" H (19.5mm x 6.1mm x 10.2mm) Through Hole 6-SIP Module, 5 Leads Isolated Module SCP TMA 1505 16.5V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 1 W 2 100mA, 100mA 13.5V 72% 5V -5V - - 1 kV
TDR 2-1211 Traco Power TDR 2-1211 27.3000
RFQ
ECAD 10 0.00000000 Traco Power TDR 2 (2W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.74" L x 0.50" W x 0.34" H (18.9mm x 12.8mm x 8.7mm) Through Hole 14-DIP Module, 7 Leads Isolated Module Remote On/Off, SCP TDR 2 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 1 400mA 9V 81% 5V - - - 1.6 kV
THN 30-4810WI Traco Power THN 30-4810WI 83.9000
RFQ
ECAD 2511 0.00000000 Traco Power THN 30WI (30W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP, UVLO THN 30 CB, cURus 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2311 EAR99 8504.40.9580 10 23 W 1 7A 18V 87% 3.3V - - - 1.5 kV
TEN 30-2411WI Traco Power TEN 30-2411WI 86.4200
RFQ
ECAD 2806 0.00000000 Traco Power TEN 30WI (30W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.60" W x 0.40" H (50.8mm x 40.6mm x 10.2mm) Through Hole 7-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 30 40V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 30 W 1 6A 10V 87% 5V - - - 1.5 kV
TEN 3-2410WI Traco Power TEN 3-2410WI 22.5600
RFQ
ECAD 40 0.00000000 Traco Power TEN 3WI (3W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 1.26" L x 0.79" W x 0.40" H (32.0mm x 20.0mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module SCP TEN 3 CB, cCSAus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1552 EAR99 8504.40.9580 10 2.5 W 1 750mA 9V 75% 3.3V - - - 1.5 kV
THL 3-4815WISM Traco Power THL 3-4815WISM 23.0150
RFQ
ECAD 3021 0.00000000 Traco Power THL 3WISM (3W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 0.94" L x 0.54" W x 0.32" H (24.0mm x 13.7mm x 8.3mm) Surface Mount 16-SMD Module, 7 Leads Isolated Module Remote On/Off, SCP THL 3 75V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected EAR99 8504.40.9580 10 3 W 1 125mA 18V 80% 24V - - - 1.5 kV
TEN 8-4812WI Traco Power TEN 8-4812WI 37.7400
RFQ
ECAD 63 0.00000000 Traco Power TEN 8WI (8W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 1.26" L x 0.80" W x 0.40" H (32.0mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO TEN 8 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2228 EAR99 8504.40.9580 10 8 W 1 666mA 18V 87% 12V - - - 1.5 kV
TDN 1-2421WISM Traco Power TDN 1-2421WISM 22.1500
RFQ
ECAD 1 0.00000000 Traco Power TDN 1WISM (1W) Tube Active -40°C ~ 90°C ITE (Commercial) 0.52" L x 0.36" W x 0.40" H (13.2mm x 9.1mm x 10.2mm) Surface Mount 7-SMD Module, 6 Leads Isolated Module Remote On/Off, SCP TDN 1 36V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected 1951-1883 EAR99 8504.40.9580 10 1 W 2 100mA, 100mA 9V 77% 5V -5V - - 1.6 kV
TRA 3-1213 Traco Power TRA 3-1213 11.9780
RFQ
ECAD 1968 0.00000000 Traco Power TRA 3 (3W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.6mm x 10.2mm) Through Hole 6-SIP Module, 4 Leads Isolated Module SCP TRA 3 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 1 200mA 10.8V 89% 15V - - - 1 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse