Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Accessory Type For Use With/Related Products Approval Agency Voltage - Input Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Control Features Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation Standard Number Line Regulation Load Regulation
THN 30-4810WIR Traco Power THN 30-4810WIR 83.6000
RFQ
ECAD 7 0.00000000 Traco Power THN 30WIR (30W) Tube Active -40°C ~ 105°C ITE (Commercial), Railway 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Adjustable Output, Remote On/Off CB, cURus 75V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-THN30-4810WIR EAR99 8504.40.9580 10 23 W 1 - 7A 18V 88% 3.3V - - - 3 kV 62368-1
TMR 1-0522 Traco Power TMR 1-0522 11.2500
RFQ
ECAD 1351 0.00000000 Traco Power TMR 1 (1W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.67" L x 0.30" W x 0.43" H (17.0mm x 7.6mm x 11.0mm) Through Hole 6-SIP Module, 5 Leads Isolated Module OCP, SCP TMR 1 CB, CSA 9V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2335 EAR99 8504.40.9580 10 1 W 2 - 42mA, 42mA 4.5V 77% 12V -12V - - 1.5 kV
TMV 12159HI Traco Power TMV 12159HI 10.7660
RFQ
ECAD 9975 0.00000000 Traco Power TMV-HI (1W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.5mm x 10.2mm) Through Hole 7-SIP Module, 4 Leads Isolated Module SCP TMV 12159 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 990 mW 2 33mA, 55mA 10.8V 77% 15V -9V - - 5.2 kV
THM 30-2413 Traco Power THM 30-2413 88.7400
RFQ
ECAD 7486 0.00000000 Traco Power THM 30 (30W) Tube Active -40°C ~ 80°C (With Derating) Medical 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 30 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1677 EAR99 8504.40.9580 10 30 W 1 2A 18V 90% 15V - - - 5 kV
TEN 5-1211 Traco Power TEN 5-1211 27.6400
RFQ
ECAD 161 0.00000000 Traco Power TEN 5 (6W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module SCP TEN 5 18V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2558 EAR99 8504.40.9580 10 5 W 1 1A 9V 81% 5V - - - 1.5 kV
TEN 40-4813WIE Traco Power TEN 40-4813WIE 69.1600
RFQ
ECAD 6499 0.00000000 Traco Power TEN 40WIE (40W) Tube Active -40°C ~ 85°C ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Adjustable Output, Remote On/Off TEN 40 CB, cURus 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-TEN40-4813WIE EAR99 8504.40.9580 10 40 W 1 - 2.666A 18V 92% 15V - - - 1.6 kV
TRS 2-1221 Traco Power TRS 2-1221 17.9500
RFQ
ECAD 2229 0.00000000 Traco Power TRS 2 (2W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.47" L x 0.44" W x 0.31" H (11.9mm x 11.3mm x 8.0mm) Surface Mount 7-SMD Module Isolated Module SCP TRS 2 18V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected 1951-2054 EAR99 8504.40.9580 10 2 W 2 200mA, 200mA 9V 79% 5V -5V - - 1.6 kV
TIM 3.5-4811 Traco Power TIM 3.5-4811 37.5400
RFQ
ECAD 21 0.00000000 Traco Power TIM 3.5 (3.5W) Tube Active -40°C ~ 90°C (With Derating) Medical 0.96" L x 0.57" W x 0.40" H (24.3mm x 14.4mm x 10.2mm) Through Hole 16-DIP Module, 7 Leads Isolated Module Remote On/Off, OVP, SCP TIM 3.5 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1769 EAR99 8504.40.9580 10 3.5 W 1 700mA 36V 79% 5V - - - 5 kV
THN 20-2423WI Traco Power THN 20-2423WI 57.6200
RFQ
ECAD 193 0.00000000 Traco Power THN 20WI (20W) Tube Active -40°C ~ 75°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP THN 20 CB, cURus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1702 EAR99 8504.40.9580 10 20 W 2 667mA, 667mA 9V 89% 15V -15V - - 1.5 kV
TEN 15-1223 Traco Power TEN 15-1223 58.9100
RFQ
ECAD 5868 0.00000000 Traco Power TEN 15 (15W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OVP, SCP TEN 15 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 15 W 2 500mA, 500mA 9V 84% 15V -15V - - 1.6 kV
TDN 3-2412WI Traco Power TDN 3-2412WI 23.2900
RFQ
ECAD 7981 0.00000000 Traco Power TDN 3WI (3W) Tube Active -40°C ~ 70°C ITE (Commercial) 0.52" L x 0.36" W x 0.40" H (13.2mm x 9.1mm x 10.2mm) Through Hole 7-DIP Module, 6 Leads Isolated Module Remote On/Off, SCP TDN 3 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 1 250mA 9V 83% 12V - - - 1.6 kV
TEC 2-0923 Traco Power TEC 2-0923 11.6100
RFQ
ECAD 1 0.00000000 Traco Power TEC 2 (2W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TEC 2 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1389 EAR99 8504.40.9580 10 2 W 2 67mA, 67mA 4.5V 84% 15V -15V - - 1.6 kV
TMR 3-2423WISM Traco Power TMR 3-2423WISM 24.5800
RFQ
ECAD 10 0.00000000 Traco Power TMR 3WISM (3W) Tube Active -40°C ~ 80°C ITE (Commercial) 0.75" L x 0.59" W x 0.34" H (19.0mm x 14.9mm x 8.7mm) Surface Mount 14-SMD Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 36V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 9V 84% 15V -15V - - 1.5 kV
TMR 1-1222 Traco Power TMR 1-1222 11.1400
RFQ
ECAD 309 0.00000000 Traco Power TMR 1 (1W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.67" L x 0.30" W x 0.43" H (17.0mm x 7.6mm x 11.0mm) Through Hole 6-SIP Module, 5 Leads Isolated Module OCP, SCP TMR 1 CB, CSA 18V Module download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 1 W 2 - 42mA, 42mA 9V 79% 12V -12V - - 1.5 kV
TEN-HS2 Traco Power TEN-HS2 7.3600
RFQ
ECAD 55 0.00000000 Traco Power - Bag Active TEN-HS Heat Sink TEN20WI, TEN30WI Series Power Supplies download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1066 EAR99 8504.90.9690 5
TES 5-1222 Traco Power TES 5-1222 39.0600
RFQ
ECAD 10 0.00000000 Traco Power TES 5 (5W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 1.31" L x 0.81" W x 0.40" H (33.4mm x 20.6mm x 10.2mm) Surface Mount 24-SMD Module, 14 Leads Isolated Module Remote On/Off, SCP TES 5 18V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 5 W 2 210mA, 210mA 9V 83% 12V -12V - - 1.5 kV
TSR 0.5-2425SM Traco Power TSR 0.5-2425SM 8.5700
RFQ
ECAD 7 0.00000000 Traco Power TSR 0.5SM Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.60" L x 0.38" W x 0.36" H (15.3mm x 9.6mm x 9.2mm) Surface Mount 10-SMD Module Linear Regulator Replacement Remote On/Off, OTP, SCP TSR 0.5 32V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 1.3 W 1 500mA 4.75V 87% 2.5V - - -
TMR 2-1223WIN Traco Power TMR 2-1223WIN 16.7200
RFQ
ECAD 7163 0.00000000 Traco Power TMR 2WIN (2W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.86" L x 0.37" W x 0.44" H (21.8mm x 9.3mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, OCP, SCP TMR 2 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 2 67mA, 67mA 4.5V 82% 15V -15V - - 1.5 kV
TEC 2-0915 Traco Power TEC 2-0915 10.7900
RFQ
ECAD 2177 0.00000000 Traco Power TEC 2 (2W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TEC 2 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1385 EAR99 8504.40.9580 10 2 W 1 83mA 4.5V 85% 24V - - - 1.6 kV
TEN 60-2411WIR Traco Power TEN 60-2411WIR 136.0700
RFQ
ECAD 4737 0.00000000 Traco Power TEN 60WIR (60W) Box Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 2.00" L x 1.60" W x 1.00" H (50.8mm x 40.7mm x 25.4mm) Through Hole 8-DIP Module Isolated Module Adjustable Output, Remote On/Off TEN 60 - 36V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-TEN60-2411WIR EAR99 8504.40.9580 10 60 W 1 - 12A 9V 91% 5V - - - 3 kV
TML 30115 Traco Power TML 30115 -
RFQ
ECAD 4090 0.00000000 Traco Power TML Box Obsolete -25°C ~ 60°C (With Derating) ITE (Commercial) 3.50" L x 2.50" W x 0.98" H (88.9mm x 63.5mm x 25.0mm) Through Hole 7-DIP Module, 5 Leads Enclosed Universal Input CE, cURus 90 ~ 264 VAC, 100 ~ 370 VDC - ROHS3 Compliant Not Applicable REACH Unaffected 1951-TML30115 EAR99 8504.40.9510 10 30 W 1 2A 80% 15V - - - - -
TBA 2-2423 Traco Power TBA 2-2423 4.7300
RFQ
ECAD 8371 0.00000000 Traco Power TBA 2 (2W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.6mm x 7.6mm x 10.2mm) Through Hole 6-SIP Module, 5 Leads Isolated Module SCP TBA 2 - 26.4V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 2 65mA, 65mA 21.6V 84% 15V -15V - - 1.5 kV
THN 30-1223 Traco Power THN 30-1223 80.8000
RFQ
ECAD 249 0.00000000 Traco Power THN 30 (30W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP THN 30 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 30 W 2 1A, 1A 9V 90% 15V -15V - - 1.5 kV
THL 15-4815WI Traco Power THL 15-4815WI 30.2900
RFQ
ECAD 117 0.00000000 Traco Power THL 15WI (15W) Tube Active -40°C ~ 70°C ITE (Commercial) 1.00" L x 1.00" W x 0.40" H (25.4mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP THL 15 CB 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-3331 EAR99 8504.40.9580 10 15 W 1 625mA 18V 91% 24V - - - 1.8 kV
TSV 0512D Traco Power TSV 0512D 15.1860
RFQ
ECAD 9156 0.00000000 Traco Power TSV (1W) Tube Not For New Designs -40°C ~ 85°C ITE (Commercial) 0.60" L x 0.31" W x 0.27" H (15.2mm x 8.0mm x 7.0mm) Surface Mount 22-SMD Module, 10 Leads Isolated Module SCP TSV 0512 5.5V - download ROHS3 Compliant 3 (168 Hours) REACH Unaffected TSV0512D EAR99 8504.40.9580 10 960 mW 2 40mA, 40mA 4.5V 78% 12V -12V - - 3 kV
TMR 6-7223WIR Traco Power TMR 6-7223WIR 37.3300
RFQ
ECAD 10 0.00000000 Traco Power TMR 6WIR (6W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial), Railway 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module Isolated Module Remote On/Off, OCP, SCP TMR 6 160V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2039 EAR99 8504.40.9580 10 6 W 2 200mA, 200mA 43V 86% 15V -15V - - 3 kV
TMR 3-0512WISM Traco Power TMR 3-0512WISM 23.0500
RFQ
ECAD 6407 0.00000000 Traco Power TMR 3WISM (3W) Tube Active -40°C ~ 80°C ITE (Commercial) 0.75" L x 0.59" W x 0.34" H (19.0mm x 14.9mm x 8.7mm) Surface Mount 14-SMD Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 12V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 3 W 1 250mA 4.5V 84% 12V - - - 1.5 kV
TIM 2-2413SM Traco Power TIM 2-2413SM 32.0000
RFQ
ECAD 50 0.00000000 Traco Power TIM 2SM (2W) Tube Active -40°C ~ 95°C (With Derating) Medical 0.96" L x 0.57" W x 0.40" H (24.3mm x 14.4mm x 10.2mm) Surface Mount 16-SMD Module, 7 Leads Isolated Module Remote On/Off, OVP, SCP TIM 2 36V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected 1951-1941 EAR99 8504.40.9580 10 2 W 1 134mA 18V 81% 15V - - - 5 kV
THI 0511 Traco Power THI 0511 36.3300
RFQ
ECAD 10 0.00000000 Traco Power THI 2 (2W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.26" L x 0.79" W x 0.39" H (32.0mm x 20.0mm x 10.0mm) Through Hole 24-DIP Module, 6 Leads Isolated Module SCP THI 05 5.5V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2656 EAR99 8504.40.9580 10 2 W 1 400mA 4.5V 62% 5V - - - 2.5 kV
TMR 3-1210HI Traco Power TMR 3-1210HI 23.6700
RFQ
ECAD 5478 0.00000000 Traco Power TMR 3HI (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2.3 W 1 700mA 9V 77% 3.3V - - - 3 kV