SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-GHG0HD-P-A-DK00000 Advanced Energy CX10S-GHG0HD-P-A-DK00000 -
RFQ
ECAD 3905 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHG0HD-P-A-DK00000 EAR99 8504.40.9540 1 640W 9 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 3 A 3 A
CX10S-HA0HBG-P-A-DK00000 Advanced Energy CX10S-HA0HBG-P-A-DK00000 -
RFQ
ECAD 7082 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HA0HBG-P-A-DK00000 EAR99 8504.40.9540 1 605W 8 93% 5V 24V 5V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 6 A 3 A 15 A
CX10S-HDADHH-P-A-DK00000 Advanced Energy CX10S-HDADHH-P-A-DK00000 -
RFQ
ECAD 3936 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDADHH-P-A-DK00000 EAR99 8504.40.9540 1 805W 9 93% 5V 24V 48V 5V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 21 A 4.17 A 6 A
CX10S-AA0BAD-P-A-DK00000 Advanced Energy CX10S-AA0BAD-P-A-DK00000 -
RFQ
ECAD 5813 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AA0BAD-P-A-DK00000 EAR99 8504.40.9540 1 695W 5 93% 5V 5V 12V 5V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 15 A 21 A 4.17 A
MX1-7110194-G Vicor Corporation MX1-7110194-G -
RFQ
ECAD 7957 0.00000000 Vicor Corporation - Bulk Obsolete - RoHS Compliant Not Applicable 1102-MX1-7110194-G OBSOLETE 1
CX10S-CB0BCG-P-A-DK00000 Advanced Energy CX10S-CB0BCG-P-A-DK00000 -
RFQ
ECAD 8346 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CB0BCG-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 24V 12V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 15 A 8.3 A 3 A 3 A
NMP1K2-CEHEEE-09 MEAN WELL USA Inc. NMP1K2-CEHEEE-09 823.3700
RFQ
ECAD 3512 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 4 88.5% 5V 12V 24V 12V - - 4 kV 60601-1; 62368-1 36 A 20 A 10 A 60 A
CX10S-DA0BDG-P-A-DK00000 Advanced Energy CX10S-DA0BDG-P-A-DK00000 -
RFQ
ECAD 2805 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DA0BDG-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 48V 5V 12V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 15 A 4.17 A 3 A 3 A
CX10S-BC0A0H-P-A-DK00000 Advanced Energy CX10S-BC0A0H-P-A-DK00000 -
RFQ
ECAD 7643 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BC0A0H-P-A-DK00000 EAR99 8504.40.9540 1 585W 5 93% 12V 24V 5V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 21 A 6 A 3 A
CX10S-0GBCAD-P-A-DK00000 Advanced Energy CX10S-0GBCAD-P-A-DK00000 -
RFQ
ECAD 2936 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GBCAD-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 24V 24V 12V 24V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 8.3 A 21 A 4.17 A
CX10S-G0HGBB-P-A-DK00000 Advanced Energy CX10S-G0HGBB-P-A-DK00000 -
RFQ
ECAD 5716 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0HGBB-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 3 A 3 A
NEVO+600ML-1541-DK000 Vox Power Ltd. NEVO+600ML-1541-DK000 472.5500
RFQ
ECAD 5575 0.00000000 Vox Power Ltd. NEVO+600ML Box Active -20°C ~ 70°C Medical 5.27" L x 3.06" W x 1.61" H (133.8mm x 77.7mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input NEVO+600 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download Not Applicable REACH Unaffected 2050-NEVO+600ML-1541-DK000 EAR99 8504.40.9530 1 550W 5 86% 5V 12V 12V 48V 5V - No 4 kV 60601-1 25 A 5 A 5 A 3.75 A 25 A
VI-RU003-EYYX Vicor Corporation VI-RU003-EYYX -
RFQ
ECAD 3527 0.00000000 Vicor Corporation * Bulk Obsolete VI-RU003 - 1 (Unlimited) REACH Affected EAR99 8504.40.9510 1
VI-NUV-EM Vicor Corporation VI-NUV-EM -
RFQ
ECAD 4336 0.00000000 Vicor Corporation * Bulk Obsolete VI-NUV - 1 (Unlimited) REACH Affected EAR99 8504.40.9540 1
NMP1K2-HEKHEH-00 MEAN WELL USA Inc. NMP1K2-HEKHEH-00 816.1200
RFQ
ECAD 6614 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 6 88.5% 24V 12V 48V 24V 12V 24V - 4 kV 60601-1; 62368-1 10 A 20 A 5 A 10 A 20 A 10 A
CX10S-HBHDA0-P-A-DK00000 Advanced Energy CX10S-HBHDA0-P-A-DK00000 -
RFQ
ECAD 3328 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBHDA0-P-A-DK00000 EAR99 8504.40.9540 1 685W 7 93% 5V 24V 12V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 6 A 3 A 4.17 A
CX10S-DAC0DG-P-A-DK00000 Advanced Energy CX10S-DAC0DG-P-A-DK00000 -
RFQ
ECAD 6433 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DAC0DG-P-A-DK00000 EAR99 8504.40.9540 1 825W 6 93% 48V 5V 24V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 8.3 A 4.17 A 3 A 3 A
CX10S-BCABCG-P-A-DK00000 Advanced Energy CX10S-BCABCG-P-A-DK00000 -
RFQ
ECAD 6586 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCABCG-P-A-DK00000 EAR99 8504.40.9540 1 985W 7 93% 12V 24V 5V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 21 A 15 A 8.3 A 3 A
CX10S-AAA0DH-P-A-DK00000 Advanced Energy CX10S-AAA0DH-P-A-DK00000 -
RFQ
ECAD 9461 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAA0DH-P-A-DK00000 EAR99 8504.40.9540 1 615W 6 93% 5V 5V 5V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 21 A 4.17 A 6 A 3 A
CX10S-AHBGBB-P-A-DK00000 Advanced Energy CX10S-AHBGBB-P-A-DK00000 -
RFQ
ECAD 7873 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AHBGBB-P-A-DK00000 EAR99 8504.40.9540 1 865W 8 93% 5V 5V 24V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 15 A 3 A 3 A
NMP1K2-E#K#KK-00 MEAN WELL USA Inc. NMP1K2-E#K#KK-00 641.2200
RFQ
ECAD 4631 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 960W 4 88.5% 12V 48V 48V 48V - - 4 kV 60601-1; 62368-1 20 A 5 A 5 A 5 A
CX10S-BCHD0A-P-A-DK00000 Advanced Energy CX10S-BCHD0A-P-A-DK00000 -
RFQ
ECAD 7784 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCHD0A-P-A-DK00000 EAR99 8504.40.9540 1 785W 6 93% 12V 24V 5V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 6 A 3 A 4.17 A 21 A
CX10S-DC0BGC-P-A-DK00000 Advanced Energy CX10S-DC0BGC-P-A-DK00000 -
RFQ
ECAD 7327 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DC0BGC-P-A-DK00000 EAR99 8504.40.9540 1 700W 6 93% 48V 24V 12V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 15 A 3 A 3 A 8.3 A
CX10S-DCBADH-P-A-DK00000 Advanced Energy CX10S-DCBADH-P-A-DK00000 -
RFQ
ECAD 3951 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCBADH-P-A-DK00000 EAR99 8504.40.9540 1 985W 7 93% 48V 24V 12V 5V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 15 A 21 A 4.17 A 6 A
CX10S-HHDBCH-P-A-DK00000 Advanced Energy CX10S-HHDBCH-P-A-DK00000 -
RFQ
ECAD 2160 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHDBCH-P-A-DK00000 EAR99 8504.40.9540 1 880W 9 93% 5V 24V 5V 24V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 4.17 A 15 A
CX10S-G0BBCB-P-A-DK00000 Advanced Energy CX10S-G0BBCB-P-A-DK00000 -
RFQ
ECAD 9385 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0BBCB-P-A-DK00000 EAR99 8504.40.9540 1 860W 6 93% 24V 24V 12V 12V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 15 A 8.3 A 15 A
CX10S-GAAAHD-P-A-DK00000 Advanced Energy CX10S-GAAAHD-P-A-DK00000 -
RFQ
ECAD 7309 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAAAHD-P-A-DK00000 EAR99 8504.40.9540 1 735W 8 93% 24V 24V 5V 5V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 21 A 21 A 6 A
CX10S-BHABGH-P-A-DK00000 Advanced Energy CX10S-BHABGH-P-A-DK00000 -
RFQ
ECAD 3712 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BHABGH-P-A-DK00000 EAR99 8504.40.9540 1 785W 9 93% 12V 5V 24V 5V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 21 A 15 A 3 A
NMP1K2-HHEHCH-01 MEAN WELL USA Inc. NMP1K2-HHEHCH-01 821.0300
RFQ
ECAD 3423 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 24V 24V 12V 24V 5V 24V - 4 kV 60601-1; 62368-1 10 A 10 A 20 A 10 A 36 A 10 A
CX10S-0BCGCG-P-A-DK00000 Advanced Energy CX10S-0BCGCG-P-A-DK00000 -
RFQ
ECAD 8002 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BCGCG-P-A-DK00000 EAR99 8504.40.9540 1 820W 7 93% 12V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 3 A 3 A 8.3 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse