SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
VI-NUF-IM Vicor Corporation VI-NUF-IM -
RFQ
ECAD 6246 0.00000000 Vicor Corporation * Bulk Obsolete VI-NUF - 1 (Unlimited) REACH Affected EAR99 8504.40.9540 1
NEVO+600SL-3485-DK000 Vox Power Ltd. NEVO+600SL-3485-DK000 423.1673
RFQ
ECAD 9493 0.00000000 Vox Power Ltd. NEVO+600SL Box Active -20°C ~ 70°C ITE (Commercial) 3.06" L x 3.06" W x 1.61" H (77.7mm x 77.7mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input NEVO+600 CB, CE, CSA, IEC, UL 85 ~ 264 VAC, 120 ~ 370 VDC download Not Applicable REACH Unaffected 2050-NEVO+600SL-3485-DK000 EAR99 8504.40.9530 1 600W 6 86% 24V 48V 24V 24V 12V 12V No 4 kV 60950-1; 62368-1 7.5 A 3.75 A 3.125 A 3.125 A 5 A 5 A
CX10S-0DAAGD-P-A-DK00000 Advanced Energy CX10S-0DAAGD-P-A-DK00000 -
RFQ
ECAD 3632 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DAAGD-P-A-DK00000 EAR99 8504.40.9540 1 730W 6 93% 48V 5V 5V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 21 A 3 A 3 A 4.17 A
LD10-20B05A2 Mornsun America, LLC LD10-20B05A2 -
RFQ
ECAD 2515 0.00000000 Mornsun America, LLC LD10-20Bxx (10W) Tray Obsolete -25°C ~ 70°C (With Derating) ITE (Commercial), Medical 3.78" L x 2.13" W x 1.08" H (96.0mm x 54.1mm x 27.4mm) Chassis Mount Enclosed Adjustable Output, DC Input Capable, Universal Input CE, cURus, UL 85 ~ 264 VAC, 100 ~ 370 VDC - ROHS3 Compliant 1 (Unlimited) 2725-LD10-20B05A2 EAR99 8504.40.9510 12 10W 1 76% 5V - - - - - - 4 kV 60601-1; 60950-1 2 A
MP8-1Q-1R-1W-4QQ-4NE-4NL-00 Artesyn Embedded Power MP8-1Q-1R-1W-4QQ-4NE-4NL-00 -
RFQ
ECAD 6340 0.00000000 Artesyn Embedded Power MP8 (1000W) Bulk Obsolete -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 7.00" W x 2.50" H (254.0mm x 177.8mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, PFC, Remote On/Off, Universal Input CB, CE, CSA, UL, VDE 85 ~ 264 VAC, 120 ~ 300 VDC download RoHS Compliant Not Applicable EAR99 8504.40.7018 1 1000W 9 85% 24V 28V 48V 24V 24V 15V - 8.5 A 6.7 A 4 A 4 A 2 A 8 A
NMP1K2-HHHCHH-01 MEAN WELL USA Inc. NMP1K2-HHHCHH-01 821.0300
RFQ
ECAD 8082 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 24V 24V 24V 5V 24V 24V - 4 kV 60601-1; 62368-1 10 A 10 A 10 A 36 A 10 A 10 A
NEVO+600M-2438-DK000 Vox Power Ltd. NEVO+600M-2438-DK000 441.6493
RFQ
ECAD 3674 0.00000000 Vox Power Ltd. NEVO+600M Box Active -20°C ~ 70°C Medical 5.27" L x 3.06" W x 1.61" H (133.8mm x 77.7mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input NEVO+600 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download Not Applicable REACH Unaffected 2050-NEVO+600M-2438-DK000 EAR99 8504.40.9540 1 450W 4 86% 12V 48V 24V 24V 24V - No 4 kV 60601-1 15 A 3.75 A 7.5 A 3.125 A 3.125 A
FL2-11-11376-MC Vicor Corporation FL2-11-11376-MC -
RFQ
ECAD 9973 0.00000000 Vicor Corporation * Bulk Obsolete - Not Applicable 1102-FL2-11-11376-MC OBSOLETE 1
FL3-21-209 Vicor Corporation FL3-21-209 -
RFQ
ECAD 4673 0.00000000 Vicor Corporation * Bulk Obsolete - Not Applicable 1102-FL3-21-209 OBSOLETE 1
CX10S-DBHGCB-P-A-DK00000 Advanced Energy CX10S-DBHGCB-P-A-DK00000 -
RFQ
ECAD 1408 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBHGCB-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 48V 12V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 6 A 3 A 3 A 3 A
CX10S-0DACDC-P-A-DK00000 Advanced Energy CX10S-0DACDC-P-A-DK00000 -
RFQ
ECAD 6408 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DACDC-P-A-DK00000 EAR99 8504.40.9540 1 905W 5 93% 48V 5V 24V 48V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 8.3 A 4.17 A 8.3 A
CX10S-DH000A-P-A-DK00000 Advanced Energy CX10S-DH000A-P-A-DK00000 -
RFQ
ECAD 1144 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DH000A-P-A-DK00000 EAR99 8504.40.9540 1 405W 4 93% 48V 5V 24V 5V - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 21 A
CX10S-0G0ACD-P-A-DK00000 Advanced Energy CX10S-0G0ACD-P-A-DK00000 -
RFQ
ECAD 3492 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0G0ACD-P-A-DK00000 EAR99 8504.40.9540 1 625W 5 93% 24V 24V 5V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 8.3 A 4.17 A
CX10S-GDADGD-P-A-DK00000 Advanced Energy CX10S-GDADGD-P-A-DK00000 -
RFQ
ECAD 2060 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GDADGD-P-A-DK00000 EAR99 8504.40.9540 1 945W 8 93% 24V 24V 48V 5V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 21 A 4.17 A 3 A
CX10S-C0ABB0-P-A-DK00000 Advanced Energy CX10S-C0ABB0-P-A-DK00000 -
RFQ
ECAD 5016 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0ABB0-P-A-DK00000 EAR99 8504.40.9540 1 665W 4 93% 24V 5V 12V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 15 A 15 A
GPM80D SL Power Electronics Manufacture of Condor/Ault Brands GPM80D -
RFQ
ECAD 9231 0.00000000 SL Power Electronics Manufacture of Condor/Ault Brands GPM80 (80W) Bulk Obsolete 0°C ~ 50°C (With Derating) Medical 7.00" L x 4.25" W x 1.86" H (177.8mm x 108.0mm x 47.2mm) Chassis Mount Open Frame Adjustable Output, Remote Sense, Universal Input CE, cURus, TUV 85 ~ 264 VAC download RoHS non-compliant Not Applicable 271-1049 EAR99 8504.40.6007 10 80W (110W Forced Air) 4 70% 5V 24V -12V 12V - Yes 12 A 2 A 1 A 1 A
CX10S-00CBDH-P-A-DK00000 Advanced Energy CX10S-00CBDH-P-A-DK00000 -
RFQ
ECAD 4268 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00CBDH-P-A-DK00000 EAR99 8504.40.9540 1 680W 5 93% 24V 12V 48V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 4.17 A 6 A 3 A
CX10S-0CHDDA-P-A-DK00000 Advanced Energy CX10S-0CHDDA-P-A-DK00000 -
RFQ
ECAD 9132 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0CHDDA-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 24V 5V 24V 48V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 4.17 A 4.17 A 21 A
CX10S-BH0CHD-P-A-DK00000 Advanced Energy CX10S-BH0CHD-P-A-DK00000 -
RFQ
ECAD 9947 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BH0CHD-P-A-DK00000 EAR99 8504.40.9540 1 780W 7 93% 12V 5V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 8.3 A 6 A 3 A
CX10S-CCACGC-P-A-DK00000 Advanced Energy CX10S-CCACGC-P-A-DK00000 -
RFQ
ECAD 1627 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CCACGC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 21 A 8.3 A 3 A 3 A
NMP1K2-#KH#K#-00 MEAN WELL USA Inc. NMP1K2-#KH#K#-00 553.7800
RFQ
ECAD 2279 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 720W 3 88.5% 48V 24V 48V - - - 4 kV 60601-1; 62368-1 5 A 10 A 5 A
CX10S-0BCDDA-P-A-DK00000 Advanced Energy CX10S-0BCDDA-P-A-DK00000 -
RFQ
ECAD 7635 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BCDDA-P-A-DK00000 EAR99 8504.40.9540 1 885W 5 93% 12V 24V 48V 48V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 4.17 A 4.17 A 21 A
NMP1K2-HHCC#H-03 MEAN WELL USA Inc. NMP1K2-HHCC#H-03 733.5900
RFQ
ECAD 5049 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1080W 4 88.5% 24V 24V 5V 24V - - 4 kV 60601-1; 62368-1 10 A 10 A 72 A 10 A
CX10S-HBD00B-P-A-DK00000 Advanced Energy CX10S-HBD00B-P-A-DK00000 -
RFQ
ECAD 8418 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HBD00B-P-A-DK00000 EAR99 8504.40.9540 1 660W 5 93% 5V 24V 12V 48V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 15 A 4.17 A 15 A
CX10S-BGHDCH-P-A-DK00000 Advanced Energy CX10S-BGHDCH-P-A-DK00000 -
RFQ
ECAD 8267 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BGHDCH-P-A-DK00000 EAR99 8504.40.9540 1 900W 9 93% 12V 24V 24V 5V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 6 A 3 A 4.17 A
CX10S-0BG0GA-P-A-DK00000 Advanced Energy CX10S-0BG0GA-P-A-DK00000 -
RFQ
ECAD 8913 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BG0GA-P-A-DK00000 EAR99 8504.40.9540 1 525W 6 93% 12V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 3 A 3 A 3 A 3 A 21 A
CX10S-DBHBBD-P-A-DK00000 Advanced Energy CX10S-DBHBBD-P-A-DK00000 -
RFQ
ECAD 9152 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DBHBBD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 12V 5V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 6 A 3 A 15 A 15 A
MBC150-1024G Bel Power Solutions MBC150-1024G 90.2700
RFQ
ECAD 68 0.00000000 Bel Power Solutions MBC150 (150W) Box Not For New Designs -20°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Standby Output, Universal Input MBC150 - 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 24 110W (150W Forced Air) 1 86% 24V - - - - No 5.9 kV 4.17 A
NEVO+600SL-2888-DK000 Vox Power Ltd. NEVO+600SL-2888-DK000 423.1673
RFQ
ECAD 9499 0.00000000 Vox Power Ltd. NEVO+600SL Box Active -20°C ~ 70°C ITE (Commercial) 3.06" L x 3.06" W x 1.61" H (77.7mm x 77.7mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input NEVO+600 CB, CE, CSA, IEC, UL 85 ~ 264 VAC, 120 ~ 370 VDC download Not Applicable REACH Unaffected 2050-NEVO+600SL-2888-DK000 EAR99 8504.40.9530 1 600W 7 86% 12V 24V 24V 24V 24V 24V No 4 kV 60950-1; 62368-1 15 A 3.125 A 3.125 A 3.125 A 3.125 A 3.125 A
CX10S-CC0CH0-P-A-DK00000 Advanced Energy CX10S-CC0CH0-P-A-DK00000 -
RFQ
ECAD 7558 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CC0CH0-P-A-DK00000 EAR99 8504.40.9540 1 700W 5 93% 24V 24V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 8.3 A 6 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2