Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-GAABBC-P-A-DK00000 Advanced Energy CX10S-GAABBC-P-A-DK00000 -
RFQ
ECAD 6208 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAABBC-P-A-DK00000 EAR99 8504.40.9540 1 890W 7 93% 24V 24V 5V 5V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 21 A 15 A 15 A
CX10S-DGA0HG-P-A-DK00000 Advanced Energy CX10S-DGA0HG-P-A-DK00000 -
RFQ
ECAD 9294 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGA0HG-P-A-DK00000 EAR99 8504.40.9540 1 645W 8 93% 48V 24V 24V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 21 A 6 A 3 A
CX10S-D0HCGG-P-A-DK00000 Advanced Energy CX10S-D0HCGG-P-A-DK00000 -
RFQ
ECAD 2389 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0HCGG-P-A-DK00000 EAR99 8504.40.9540 1 740W 8 93% 48V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 8.3 A 3 A 3 A
IMP4-3Q0-LLL-00-A Artesyn Embedded Power IMP4-3Q0-LLL-00-A -
RFQ
ECAD 6367 0.00000000 Artesyn Embedded Power iMP® (1158W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP4-3Q0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download RoHS Compliant 1 (Unlimited) EAR99 8504.40.9580 1 1100W 4 85% 24V 12V 12V 12V - - No 2 kV 30 A 1 A 1 A 1 A
NMP1K2-#KKHEH-00 MEAN WELL USA Inc. NMP1K2-#KKHEH-00 728.6700
RFQ
ECAD 6204 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 48V 48V 24V 12V 24V - - 4 kV 60601-1; 62368-1 5 A 5 A 10 A 20 A 10 A
CX10S-ACHDAB-P-A-DK00000 Advanced Energy CX10S-ACHDAB-P-A-DK00000 -
RFQ
ECAD 2342 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACHDAB-P-A-DK00000 EAR99 8504.40.9540 1 890W 7 93% 5V 24V 5V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 6 A 3 A 4.17 A 21 A
PMA100F-5-J1N Cosel USA, Inc. PMA100F-5-J1N 151.5300
RFQ
ECAD 7849 0.00000000 Cosel USA, Inc. PMA (100W) Box Active -10°C ~ 70°C Medical 6.61" L x 1.34" W x 3.66" H (167.9mm x 34.0mm x 93.0mm) Chassis Mount Enclosed PMA100F CE, cURus, TUV 85 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9520 1 1 83% 5V - - - - No 2 kV 20 A
CX10S-0BDCGH-P-A-DK00000 Advanced Energy CX10S-0BDCGH-P-A-DK00000 -
RFQ
ECAD 9622 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BDCGH-P-A-DK00000 EAR99 8504.40.9540 1 800W 7 93% 12V 48V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 8.3 A 3 A 3 A 6 A
CX10S-BDD0GC-P-A-DK00000 Advanced Energy CX10S-BDD0GC-P-A-DK00000 -
RFQ
ECAD 6151 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BDD0GC-P-A-DK00000 EAR99 8504.40.9540 1 900W 6 93% 12V 48V 48V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 4.17 A 3 A 3 A 8.3 A
CX10S-0GGGAG-P-A-DK00000 Advanced Energy CX10S-0GGGAG-P-A-DK00000 -
RFQ
ECAD 7226 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GGGAG-P-A-DK00000 EAR99 8504.40.9540 1 585W 9 93% 24V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 3 A 3 A
NMP1K2-HHEEEH-08 MEAN WELL USA Inc. NMP1K2-HHEEEH-08 823.3700
RFQ
ECAD 9045 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 4 88.5% 24V 24V 12V 24V - - 4 kV 60601-1; 62368-1 10 A 10 A 60 A 10 A
NMP1K2-KKKHEC-06 MEAN WELL USA Inc. NMP1K2-KKKHEC-06 823.3700
RFQ
ECAD 3354 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 4 88.5% 48V 24V 12V 5V - - 4 kV 60601-1; 62368-1 15 A 10 A 20 A 36 A
CX10S-HDCHAD-P-A-DK00000 Advanced Energy CX10S-HDCHAD-P-A-DK00000 -
RFQ
ECAD 1105 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDCHAD-P-A-DK00000 EAR99 8504.40.9540 1 905W 8 93% 5V 24V 48V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 8.3 A 6 A 3 A
CX10S-GA00CD-P-A-DK00000 Advanced Energy CX10S-GA00CD-P-A-DK00000 -
RFQ
ECAD 8185 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GA00CD-P-A-DK00000 EAR99 8504.40.9540 1 625W 5 93% 24V 24V 5V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 8.3 A 4.17 A
CX10S-HGAHH0-P-A-DK00000 Advanced Energy CX10S-HGAHH0-P-A-DK00000 -
RFQ
ECAD 9896 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGAHH0-P-A-DK00000 EAR99 8504.40.9540 1 525W 9 93% 5V 24V 24V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 21 A 6 A
CX10S-D0HHHG-P-A-DK00000 Advanced Energy CX10S-D0HHHG-P-A-DK00000 -
RFQ
ECAD 4896 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-D0HHHG-P-A-DK00000 EAR99 8504.40.9540 1 620W 9 93% 48V 5V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 6 A 3 A 6 A
CX10S-C00HBB-P-A-DK00000 Advanced Energy CX10S-C00HBB-P-A-DK00000 -
RFQ
ECAD 4619 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C00HBB-P-A-DK00000 EAR99 8504.40.9540 1 660W 5 93% 24V 5V 24V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 15 A 15 A
CX10S-HA0GHH-P-A-DK00000 Advanced Energy CX10S-HA0GHH-P-A-DK00000 -
RFQ
ECAD 2374 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HA0GHH-P-A-DK00000 EAR99 8504.40.9540 1 525W 9 93% 5V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 3 A 3 A 6 A
CX10S-A0GH00-P-A-DK00000 Advanced Energy CX10S-A0GH00-P-A-DK00000 -
RFQ
ECAD 8573 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0GH00-P-A-DK00000 EAR99 8504.40.9540 1 325W 5 93% 5V 24V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 6 A 3 A
CX10S-AGBACC-P-A-DK00000 Advanced Energy CX10S-AGBACC-P-A-DK00000 -
RFQ
ECAD 1908 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGBACC-P-A-DK00000 EAR99 8504.40.9540 1 910W 7 93% 5V 24V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 15 A 21 A 8.3 A
CX10S-DD0CDC-P-A-DK00000 Advanced Energy CX10S-DD0CDC-P-A-DK00000 -
RFQ
ECAD 8924 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DD0CDC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 5 93% 48V 48V 24V 48V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 8.3 A 4.17 A 8.3 A
CX10S-0HHHHA-P-A-DK00000 Advanced Energy CX10S-0HHHHA-P-A-DK00000 -
RFQ
ECAD 1872 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0HHHHA-P-A-DK00000 EAR99 8504.40.9540 1 505W 9 93% 5V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 6 A 3 A
CX10S-AHA0BD-P-A-DK00000 Advanced Energy CX10S-AHA0BD-P-A-DK00000 -
RFQ
ECAD 1600 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AHA0BD-P-A-DK00000 EAR99 8504.40.9540 1 690W 6 93% 5V 5V 24V 5V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 21 A 15 A 4.17 A
ZWS30B-3/A TDK-Lambda Americas Inc ZWS30B-3/A 51.1200
RFQ
ECAD 1351 0.00000000 TDK-Lambda Americas Inc ZWS30B (30W) Bulk Active -10°C ~ 70°C (With Derating) ITE (Commercial) 4.13" L x 1.97" W x 1.04" H (105.0mm x 50.0mm x 26.5mm) Chassis Mount Enclosed Adjustable Output, Universal Input ZWS30B CE 85 ~ 265 VAC, 120 ~ 370 VDC download RoHS Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9510 1 20W 1 77% 3.3V - - - - - - 3 kV 6 A
CX10S-DAA0AB-P-A-DK00000 Advanced Energy CX10S-DAA0AB-P-A-DK00000 -
RFQ
ECAD 3371 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DAA0AB-P-A-DK00000 EAR99 8504.40.9540 1 695W 5 93% 48V 5V 5V 5V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 21 A 21 A 15 A
CX10S-HGBBC0-P-A-DK00000 Advanced Energy CX10S-HGBBC0-P-A-DK00000 -
RFQ
ECAD 6942 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGBBC0-P-A-DK00000 EAR99 8504.40.9540 1 780W 7 93% 5V 24V 24V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 15 A 15 A
CX10S-C0G0BB-P-A-DK00000 Advanced Energy CX10S-C0G0BB-P-A-DK00000 -
RFQ
ECAD 6787 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0G0BB-P-A-DK00000 EAR99 8504.40.9540 1 680W 5 93% 24V 24V 24V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 15 A 15 A
AMES100-5S277NZ aimtec AMES100-5S277NZ 34.0200
RFQ
ECAD 2 0.00000000 aimtec AMES100-277NZ Box Active -30°C ~ 70°C (With Derating) Household Appliances, ITE (Commercial) 5.08" L x 3.82" W x 1.18" H (129.0mm x 97.0mm x 30.0mm) Chassis Mount Enclosed Adjustable Output AMES100 CB, CE, EN, IEC, UL 85 ~ 305 VAC, 120 ~ 430 VDC download ROHS3 Compliant 1 (Unlimited) REACH info available upon request 2721-AMES100-5S277NZ EAR99 8504.40.9582 1 90W 1 85.5% 5V - - - - - - 4 kV 60335-1; 62368-1 18 A
CX10S-GGCGCB-P-A-DK00000 Advanced Energy CX10S-GGCGCB-P-A-DK00000 -
RFQ
ECAD 1391 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGCGCB-P-A-DK00000 EAR99 8504.40.9540 1 940W 9 93% 24V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 8.3 A 3 A
CX10S-GHAHAH-P-A-DK00000 Advanced Energy CX10S-GHAHAH-P-A-DK00000 -
RFQ
ECAD 1419 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHAHAH-P-A-DK00000 EAR99 8504.40.9540 1 630W 10 93% 24V 24V 5V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 21 A 6 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2