Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-BADCCD-P-A-DK00000 | - | ![]() |
6152 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-BADCCD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 6 | 93% | 12V | 5V | 48V | 24V | 24V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 21 A | 4.17 A | 8.3 A | 8.3 A | 4.17 A | |||
![]() |
CX10S-CB00HA-P-A-DK00000 | - | ![]() |
3323 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CB00HA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 585W | 5 | 93% | 24V | 12V | 5V | 24V | 5V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 15 A | 6 A | 3 A | 21 A | ||||
![]() |
NMP1K2-#CEKEE-00 | 728.6700 | ![]() |
4200 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 5 | 88.5% | 5V | 12V | 48V | 12V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 36 A | 20 A | 5 A | 20 A | 20 A | |||
![]() |
LDA150W-24-R | - | ![]() |
1376 | 0.00000000 | Cosel USA, Inc. | LDA (150W) | Box | Obsolete | -10°C ~ 60°C (With Derating) | ITE (Commercial) | 8.74" L x 2.95" W x 1.46" H (222.0mm x 75.0mm x 37.0mm) | Chassis Mount | Open Frame | Adjustable Output, Remote On/Off, Universal Input | LDA150W | cCSAus, CE, cURus, TUV | 85 ~ 132 VAC, 170 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | EAR99 | 8504.40.9520 | 1 | 151W | 1 | 85% | 24V | - | - | - | - | - | - | 60950-1 | 6.3 A | |||||||||
![]() |
CX10S-0GDHAA-P-A-DK00000 | - | ![]() |
1608 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0GDHAA-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 630W | 7 | 93% | 24V | 24V | 48V | 5V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 4.17 A | 6 A | 3 A | 21 A | |||
![]() |
NMP1K2-EEC#EE-05 | 698.9800 | ![]() |
2412 | 0.00000000 | MEAN WELL USA Inc. | NMP (1200W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial), Medical | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | NMP1K2 | CB, CE, cURus, EAC, TUV | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9540 | 1 | 1140W | 4 | 88.5% | 12V | 12V | 5V | 12V | - | - | 4 kV | 60601-1; 62368-1 | 20 A | 20 A | 36 A | 40 A | |||||
![]() |
CX10S-AHBG0B-P-A-DK00000 | - | ![]() |
3718 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-AHBG0B-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 685W | 7 | 93% | 5V | 5V | 24V | 12V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 6 A | 3 A | 15 A | 3 A | 3 A | |||
![]() |
CX10S-0CGACC-P-A-DK00000 | - | ![]() |
8451 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0CGACC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 825W | 6 | 93% | 24V | 24V | 24V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 3 A | 3 A | 21 A | 8.3 A | 8.3 A | |||
![]() |
CX10S-GAH0BH-P-A-DK00000 | - | ![]() |
3785 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-GAH0BH-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 605W | 8 | 93% | 24V | 24V | 5V | 5V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 3 A | 3 A | 21 A | 6 A | 3 A | 15 A | |||
![]() |
AC220S24ZB-60WH2 | 41.5000 | ![]() |
20 | 0.00000000 | HenLv Power | - | Case | Active | - | - | 85 ~ 305 VAC, 120 ~ 430 VDC | - | Vendor Undefined | 3986-AC220S24ZB-60WH2 | 1 | 60W | 80% | 24V | 4000 V | |||||||||||||||||||||||||
![]() |
CX10S-DCCCDC-P-A-DK00000 | - | ![]() |
9160 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-DCCCDC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 6 | 93% | 48V | 24V | 24V | 24V | 48V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 8.3 A | 8.3 A | 8.3 A | 4.17 A | 8.3 A | |||
![]() |
CX10S-CBCDDD-P-A-DK00000 | - | ![]() |
2940 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CBCDDD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 6 | 93% | 24V | 12V | 24V | 48V | 48V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 15 A | 8.3 A | 4.17 A | 4.17 A | 4.17 A | |||
![]() |
CX10S-B0CADC-P-A-DK00000 | - | ![]() |
4540 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-B0CADC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 885W | 5 | 93% | 12V | 24V | 5V | 48V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 8.3 A | 21 A | 4.17 A | 8.3 A | ||||
![]() |
CX10S-00ADBC-P-A-DK00000 | - | ![]() |
4129 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-00ADBC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 685W | 4 | 93% | 5V | 48V | 12V | 24V | - | - | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 4.17 A | 15 A | 8.3 A | |||||
![]() |
CX10S-0BD0GG-P-A-DK00000 | - | ![]() |
9817 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0BD0GG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 620W | 6 | 93% | 12V | 48V | 24V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 4.17 A | 3 A | 3 A | 3 A | 3 A | |||
![]() |
CX10S-CCDHAD-P-A-DK00000 | - | ![]() |
5205 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CCDHAD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 7 | 93% | 24V | 24V | 48V | 5V | 24V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 8.3 A | 4.17 A | 6 A | 3 A | 21 A | |||
![]() |
CX10S-0HBBGC-P-A-DK00000 | - | ![]() |
1192 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-0HBBGC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 780W | 7 | 93% | 5V | 24V | 12V | 12V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 15 A | 15 A | 3 A | 3 A | |||
![]() |
CX10S-CGCBHG-P-A-DK00000 | - | ![]() |
2560 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CGCBHG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 920W | 9 | 93% | 24V | 24V | 24V | 24V | 12V | 5V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 3 A | 3 A | 8.3 A | 15 A | 6 A | |||
![]() |
CX10S-BAD0AG-P-A-DK00000 | - | ![]() |
6728 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-BAD0AG-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 710W | 6 | 93% | 12V | 5V | 48V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 15 A | 21 A | 4.17 A | 21 A | 3 A | 3 A | |||
![]() |
CX10S-HACGD0-P-A-DK00000 | - | ![]() |
1296 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-HACGD0-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 725W | 7 | 93% | 5V | 24V | 5V | 24V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 6 A | 3 A | 21 A | 8.3 A | 3 A | 3 A | |||
![]() |
VI-RU410-IUYY | - | ![]() |
7496 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-RU410 | - | 1 (Unlimited) | REACH Affected | OBSOLETE | 1 | ||||||||||||||||||||||||||||||
![]() |
LDA300W-30-GT | - | ![]() |
1811 | 0.00000000 | Cosel USA, Inc. | LDA (300W) | Box | Obsolete | -10°C ~ 70°C (With Derating) | ITE (Commercial) | 10.04" L x 4.25" W x 1.85" H (255.0mm x 108.0mm x 47.0mm) | Chassis Mount | Open Frame | Adjustable Output, Universal Input | LDA300W | cCSAus, CE, cURus, TUV | 85 ~ 132 VAC, 170 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | EAR99 | 8504.40.9530 | 1 | 300W | 1 | 86% | 30V | - | - | - | - | - | - | 60950-1 | 10 A | |||||||||
![]() |
RTW05-30R | 387.4500 | ![]() |
1623 | 0.00000000 | TDK-Lambda Americas Inc | RTW | Bulk | Not For New Designs | -10°C ~ 71°C (With Derating) | ITE (Commercial) | 7.09" L x 1.15" W x 3.62" H (180.0mm x 29.2mm x 92.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Remote On/Off, Remote Sense, Universal Input | RTW05 | CE, cURus, TUV | 85 ~ 265 VAC | download | RoHS Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 150W | 1 | 86% | 5V | - | - | - | - | No | 3 kV | 30 A | |||||||||
![]() |
VI-RU011-EUWY | - | ![]() |
8297 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-RU011 | - | 1 (Unlimited) | OBSOLETE | 1 | |||||||||||||||||||||||||||||||
![]() |
NEVO+600ML-4085-DK000 | 385.7493 | ![]() |
6959 | 0.00000000 | Vox Power Ltd. | NEVO+600ML | Box | Active | -20°C ~ 70°C | Medical | 5.27" L x 3.06" W x 1.61" H (133.8mm x 77.7mm x 41.0mm) | Chassis Mount | Enclosed | Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input | NEVO+600 | CB, CE, CSA, UL | 85 ~ 264 VAC, 120 ~ 300 VDC | download | Not Applicable | REACH Unaffected | 2050-NEVO+600ML-4085-DK000 | EAR99 | 8504.40.9530 | 1 | 450W | 5 | 86% | 48V | 24V | 24V | 12V | 12V | - | No | 4 kV | 60601-1 | 3.75 A | 3.125 A | 3.125 A | 5 A | 5 A | |||
![]() |
CX10S-DHAGGC-P-A-DK00000 | - | ![]() |
6056 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-DHAGGC-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 845W | 9 | 93% | 48V | 5V | 24V | 5V | 24V | 24V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 4.17 A | 6 A | 3 A | 21 A | 3 A | 3 A | |||
![]() |
VI-RU034-EYYX | - | ![]() |
6661 | 0.00000000 | Vicor Corporation | * | Bulk | Obsolete | VI-RU034 | - | 1 (Unlimited) | REACH Affected | EAR99 | 8504.40.9510 | 1 | |||||||||||||||||||||||||||||
![]() |
CX10S-CBCDAD-P-A-DK00000 | - | ![]() |
5958 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-CBCDAD-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 6 | 93% | 24V | 12V | 24V | 48V | 5V | 48V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 8.3 A | 15 A | 8.3 A | 4.17 A | 21 A | 4.17 A | |||
![]() |
LPS113-B | - | ![]() |
6075 | 0.00000000 | Artesyn Embedded Power | LPS110 (110W) | Bulk | Obsolete | 0°C ~ 70°C (With Derating) | ITE (Commercial) | 4.28" L x 7.30" W x 2.20" H (108.6mm x 185.5mm x 56.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Remote Sense, Universal Input | CB, CE | 85 ~ 264 VAC | download | RoHS non-compliant | 1 (Unlimited) | EAR99 | 8504.40.6018 | 60 | 80W (110W Forced Air) | 1 | 70% | 12V | - | - | - | - | No | 9.2 A | ||||||||||||
![]() |
CX10S-ABDDCB-P-A-DK00000 | - | ![]() |
4107 | 0.00000000 | Advanced Energy | COOLX®1000 | Box | Active | -40°C ~ 85°C | ITE (Commercial), Medical | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) | Chassis Mount | Enclosed | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | CX10S | CSA, EN, IEC, UL | 85 ~ 264 VAC | download | REACH Affected | 633-CX10S-ABDDCB-P-A-DK00000 | EAR99 | 8504.40.9540 | 1 | 1000W | 6 | 93% | 5V | 12V | 48V | 48V | 24V | 12V | No | 4 kV | 60601-1; 60950-1; 62368-1 | 21 A | 15 A | 4.17 A | 4.17 A | 8.3 A | 15 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse