SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-CAHDHG-P-A-DK00000 Advanced Energy CX10S-CAHDHG-P-A-DK00000 -
RFQ
ECAD 1590 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CAHDHG-P-A-DK00000 EAR99 8504.40.9540 1 825W 9 93% 24V 5V 5V 24V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 6 A 3 A 4.17 A 6 A
IMP4-3N0-LLE-NNE-00-A Artesyn Embedded Power IMP4-3N0-LLE-NNE-00-A -
RFQ
ECAD 3918 0.00000000 Artesyn Embedded Power iMP® (1158W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP4-3N0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download RoHS Compliant Not Applicable EAR99 8504.40.9540 1 779W 7 85% 15V 12V 12V 5V 15V 15V No 2 kV 50 A 1 A 1 A 2 A 1 A 1 A
PMT-D1V100W1AH Delta Electronics PMT-D1V100W1AH 43.0510
RFQ
ECAD 5946 0.00000000 Delta Electronics PMT (99W) Bulk Active -10°C ~ 70°C (With Derating) ITE (Commercial) 7.01" L x 3.82" W x 1.50" H (178.0mm x 97.0mm x 38.0mm) Chassis Mount Enclosed Adjustable Output PMT-D1 CB, CCC, CE, cURus, TUVgs 88 ~ 132 VAC, 176 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018 20 100W 2 82% 12V 5V - - - - 3 kV 7 A 3 A
WX5-4113470-G Vicor Corporation WX5-4113470-G -
RFQ
ECAD 5577 0.00000000 Vicor Corporation - Bulk Obsolete - Not Applicable 1102-WX5-4113470-G OBSOLETE 1
MP8-2U-2U-1N-1N-03 Artesyn Embedded Power MP8-2U-2U-1N-1N-03 -
RFQ
ECAD 2566 0.00000000 Artesyn Embedded Power MP8 (1000W) Bulk Obsolete -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 7.00" W x 2.50" H (254.0mm x 177.8mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, PFC, Remote On/Off, Universal Input CB, CE, CSA, UL, VDE 85 ~ 264 VAC, 120 ~ 300 VDC download Not Applicable EAR99 8504.40.7018 1 1000W 4 85% 36V 36V 15V 15V - - - 10 A 10 A 14 A 14 A
CX10S-C0GDCA-P-A-DK00000 Advanced Energy CX10S-C0GDCA-P-A-DK00000 -
RFQ
ECAD 2980 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0GDCA-P-A-DK00000 EAR99 8504.40.9540 1 825W 6 93% 24V 24V 24V 48V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 4.17 A 8.3 A 21 A
CX10S-GCGA0G-P-A-DK00000 Advanced Energy CX10S-GCGA0G-P-A-DK00000 -
RFQ
ECAD 7251 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCGA0G-P-A-DK00000 EAR99 8504.40.9540 1 465W 8 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 3 A 3 A 21 A
LPS55-M Artesyn Embedded Power LPS55-M -
RFQ
ECAD 6729 0.00000000 Artesyn Embedded Power LPS50-M (60W) Bulk Obsolete 0°C ~ 70°C (With Derating) Medical 4.00" L x 2.00" W x 1.30" H (101.6mm x 50.8mm x 33.0mm) Chassis Mount Open Frame Adjustable Output, DC Input Capable, Remote Sense, Universal Input CE 90 ~ 264 VAC - 1 (Unlimited) EAR99 8504.40.6018 200 55W 1 85% 24V - - - - No 2.5 A
NMP1K2-EKCHEC-00 MEAN WELL USA Inc. NMP1K2-EKCHEC-00 816.1200
RFQ
ECAD 3742 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 6 88.5% 12V 48V 5V 24V 12V 5V - 4 kV 60601-1; 62368-1 20 A 5 A 36 A 10 A 20 A 36 A
CX10S-HCC0GC-P-A-DK00000 Advanced Energy CX10S-HCC0GC-P-A-DK00000 -
RFQ
ECAD 2098 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HCC0GC-P-A-DK00000 EAR99 8504.40.9540 1 620W 7 93% 5V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 8.3 A 8.3 A 3 A 3 A
CX10S-BADBCH-P-A-DK00000 Advanced Energy CX10S-BADBCH-P-A-DK00000 -
RFQ
ECAD 7119 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BADBCH-P-A-DK00000 EAR99 8504.40.9540 1 965W 7 93% 12V 5V 48V 12V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 4.17 A 15 A 8.3 A 6 A
CX10S-AHBHCH-P-A-DK00000 Advanced Energy CX10S-AHBHCH-P-A-DK00000 -
RFQ
ECAD 1587 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AHBHCH-P-A-DK00000 EAR99 8504.40.9540 1 785W 9 93% 5V 5V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 15 A 6 A 3 A
CX10S-BBGHDH-P-A-DK00000 Advanced Energy CX10S-BBGHDH-P-A-DK00000 -
RFQ
ECAD 2111 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BBGHDH-P-A-DK00000 EAR99 8504.40.9540 1 880W 9 93% 12V 12V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 3 A 3 A 6 A 3 A
CX10S-GCDHGD-P-A-DK00000 Advanced Energy CX10S-GCDHGD-P-A-DK00000 -
RFQ
ECAD 6932 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCDHGD-P-A-DK00000 EAR99 8504.40.9540 1 940W 9 93% 24V 24V 24V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 4.17 A 6 A 3 A
IVS6-2E0-00-A Artesyn Embedded Power IVS6-2E0-00-A -
RFQ
ECAD 6233 0.00000000 Artesyn Embedded Power iVS™ 6 (3120W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 11.00" L x 5.00" W x 5.00" H (279.4mm x 127.0mm x 127.0mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, Remote Sense, Universal Input IVS6-2E0 CB, CE, CSA, UL 170 ~ 264 VAC (3 Phase) download RoHS Compliant 1 (Unlimited) EAR99 8504.40.9540 1 300W 1 85% 5V - - - - No 2 kV 60 A
GSM28-24 SL Power Electronics Manufacture of Condor/Ault Brands GSM28-24 -
RFQ
ECAD 7369 0.00000000 SL Power Electronics Manufacture of Condor/Ault Brands GSM28 (28W) Bulk Obsolete 0°C ~ 50°C Medical 4.00" L x 2.59" W x 0.92" H (101.6mm x 65.8mm x 23.4mm) Chassis Mount Open Frame Universal Input CE, cURus, TUV 85 ~ 264 VAC download RoHS non-compliant Not Applicable 271-1123 EAR99 8504.40.6018 1 28W 1 70% 24V - - - - Yes 1.2 A
CX10S-CG0ACH-P-A-DK00000 Advanced Energy CX10S-CG0ACH-P-A-DK00000 -
RFQ
ECAD 9661 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CG0ACH-P-A-DK00000 EAR99 8504.40.9540 1 725W 7 93% 24V 24V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 21 A 8.3 A 6 A
CX10S-HGHD0G-P-A-DK00000 Advanced Energy CX10S-HGHD0G-P-A-DK00000 -
RFQ
ECAD 2367 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGHD0G-P-A-DK00000 EAR99 8504.40.9540 1 640W 9 93% 5V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 6 A 3 A
CX10S-CGDBCG-P-A-DK00000 Advanced Energy CX10S-CGDBCG-P-A-DK00000 -
RFQ
ECAD 7634 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGDBCG-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 24V 24V 24V 48V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 4.17 A 15 A 8.3 A
GLC75D SL Power Electronics Manufacture of Condor/Ault Brands GLC75D -
RFQ
ECAD 8602 0.00000000 SL Power Electronics Manufacture of Condor/Ault Brands GLC75 (75W) Bulk Obsolete 0°C ~ 50°C ITE (Commercial) 5.75" L x 3.40" W x 1.56" H (146.0mm x 86.4mm x 39.7mm) Chassis Mount Open Frame Universal Input CE 90 ~ 264 VAC download RoHS non-compliant Not Applicable EAR99 8504.40.6007 15 75W 4 85% 5.1V 24V -12V 12V - No 8 A 3 A 1 A 3 A
CX10S-GCC0HA-P-A-DK00000 Advanced Energy CX10S-GCC0HA-P-A-DK00000 -
RFQ
ECAD 7563 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCC0HA-P-A-DK00000 EAR99 8504.40.9540 1 725W 7 93% 24V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 8.3 A 6 A 3 A
CX10S-GCC0DC-P-A-DK00000 Advanced Energy CX10S-GCC0DC-P-A-DK00000 -
RFQ
ECAD 3287 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCC0DC-P-A-DK00000 EAR99 8504.40.9540 1 720W 6 93% 24V 24V 24V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 8.3 A 4.17 A 8.3 A
CX10S-CDHDBC-P-A-DK00000 Advanced Energy CX10S-CDHDBC-P-A-DK00000 -
RFQ
ECAD 8081 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CDHDBC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 48V 5V 24V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 6 A 3 A 4.17 A 15 A
CX10S-HDACHH-P-A-DK00000 Advanced Energy CX10S-HDACHH-P-A-DK00000 -
RFQ
ECAD 8179 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDACHH-P-A-DK00000 EAR99 8504.40.9540 1 805W 9 93% 5V 24V 48V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 21 A 8.3 A 6 A
IMP4-1D0-1H0-1H0-1Q0-00-A Artesyn Embedded Power IMP4-1D0-1H0-1H0-1Q0-00-A -
RFQ
ECAD 2098 0.00000000 Artesyn Embedded Power iMP® (1158W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP4-1D0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download RoHS Compliant 1 (Unlimited) EAR99 8504.40.9580 1 1100W 4 85% 3.3V 6V 6V 24V - - No 2 kV 35 A 23 A 23 A 8.5 A
CX10S-DHCA0H-P-A-DK00000 Advanced Energy CX10S-DHCA0H-P-A-DK00000 -
RFQ
ECAD 8322 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHCA0H-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 48V 5V 24V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 8.3 A 21 A 6 A
CX10S-DGBGDG-P-A-DK00000 Advanced Energy CX10S-DGBGDG-P-A-DK00000 -
RFQ
ECAD 9214 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGBGDG-P-A-DK00000 EAR99 8504.40.9540 1 940W 9 93% 48V 24V 24V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 15 A 3 A 3 A
AMES100-051212TNZ aimtec AMES100-051212TNZ 43.9000
RFQ
ECAD 7735 0.00000000 aimtec AMES100-NZ Box Active -30°C ~ 70°C (With Derating) Household Appliances 6.26" L x 3.82" W x 1.18" H (159.0mm x 97.0mm x 30.0mm) Chassis Mount Enclosed Adjustable Output, DC Input Capable, Universal Input cURus 90 ~ 264 VAC, 120 ~ 373 VDC download ROHS3 Compliant Not Applicable REACH info available upon request 2721-AMES100-051212TNZ 8504.40.9530 5 94W 3 84% 5V 12V 12V - - - - 4 kV 60335-1 8 A 3.5 A 1 A
CX10S-GBBGH0-P-A-DK00000 Advanced Energy CX10S-GBBGH0-P-A-DK00000 -
RFQ
ECAD 2841 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBBGH0-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 24V 24V 12V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 15 A 3 A 3 A
NMP1K2-HCCCC#-02 MEAN WELL USA Inc. NMP1K2-HCCCC#-02 733.5900
RFQ
ECAD 3989 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 960W 4 88.5% 24V 5V 5V 5V - - 4 kV 60601-1; 62368-1 10 A 72 A 36 A 36 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse